Chauvin Arnoux PEL Power-Energy Loggers
Electrical contractors and business owners, the Chauvin Arnoux PEL Power-Energy Loggers transcend simple voltage and current readings, delivering comprehensive analysis of key parameters like energy usage, power efficiency, and maximum load, saving time and money. Find out more below or call 01642 931329 to get expert advice.
PEL - Reduce Your Energy Bills
Chauvin Arnoux PEL Applications
Stop Energy Waste & Save Money
A PEL Power Logger identifies high-consumption periods and devices by tracking real-time and historical power usage. After implementing energy-saving strategies, quantify the actual impact on consumption, confirming effectiveness. By understanding consumption patterns, it's possible to forecast future energy bills and make informed budgeting decisions.
Avoid Costly Downtimes
Avoid equipment malfunction or impending failure by using the Chauvin Arnoux PEL Power-Energy Logger to detect abnormal spikes or fluctuations in power consumption. Early detection allows for preventive maintenance, avoiding costly breakdowns. Analysing power data can help pinpoint the source of electrical problems like power surges or voltage drops.
Improve Efficiency & Performance
Chauvin Arnoux PEL Energy Loggers provide valuable data for engineers and researchers working on improving the efficiency of appliances, systems, and entire buildings. Not only this, but many companies and contractors are now able to track the output of EV chargers, solar panels, wind turbines, or other renewable energy sources, ensuring optimal performance.
Which PEL Do I Need?
Domestic & Smaller Commercial Installations
Chauvin Arnoux PEL50 Series
- Single phase logging
- Carries out maximum demand surveys
- Pre-installation surveys for PV and EV
- Identifies power disruptions and nuisance tripping
- Includes flexible type current clamp
- Compact design
Commercial & Industrial Installations
Chauvin Arnoux PEL100 Series
- Three phase logging
- Identifies business energy savings
- Finds power quality problems like power harmonics or poor power factor
- Remotely monitors installations in real time
- Wide range of current sensors for AC and DC applications
- IP67 and built-in self-power (PEL 106 only)
Chauvin Arnoux PEL Comparison
- Phase Type
- Channels
- Acquistion Speed
- Calc. Power
- Total/Partial Energy
- Quadrant Display
- Energy Cost Calc.
- Energy Lost Calc.
- Motor Rot. Speed
- Motor Torque
- Motor Efficiency
- Bluetooth/USB
- Ethernet
- Wi-Fi
- 3G & GPRS
- Email Alerts
- LCD Display
- Self Powering
- Ext. Analogue Inputs
- IP Rating
- Max. Memory
-
- Single
- 1V/1I
- 1s
- P, Pf, N, S, Qf & D
- ✔
- ✔
- ✔
- --
- --
- --
- --
- --
- Via Simplified Wi-Fi
- ✔
- --
- --
- ✔
- Built-In
- --
- IP54
- 32Gb
-
- Split, 2 Single
- 2V/2I
- 1s
- P, Pf, N, S, Qf & D
- ✔
- ✔
- ✔
- --
- --
- --
- --
- --
- Via Simplified Wi-Fi
- ✔
- --
- --
- ✔
- Built-In
- --
- IP54
- 32Gb
-
- Single, Split, Three
- 4V & 3A
- 1s
- P, Q & S
- ✔
- ✔
- ✔
- --
- ✔
- ✔
- ✔
- ✔
- ✔
- --
- --
- --
- --
- Adaptor (Optional)
- --
- IP54
- 32Gb
-
- Single, Split, Three
- 4V & 3A
- 1s
- P, Q & S
- ✔
- ✔
- ✔
- --
- ✔
- ✔
- ✔
- ✔
- ✔
- --
- --
- --
- ✔
- Adaptor (Optional)
- --
- IP54
- 32Gb
-
- Single, Split, Three
- 4V & 3A
- 200ms
- P, N, S, Q1 & D
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- Adaptor (Included)
- 8 Using L452
- IP54
- 32Gb
-
- Single, Split, Three
- 5V & 4A
- 200ms
- P, N, S, Q1 & D
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- ✔
- Built-In
- 8 Using L452
- IP67
- 32Gb
Processing Software
Chauvin Arnoux DataView
From instrument setup and live data monitoring to post-measurement analysis and report generation, Chauvin Arnoux DataView software empowers you to take complete control of your testing process. Configure and perfom measurements, view readings in real-time, retrieve recorded data, and create standard or customised reports – all within a single, user-friendly interface.
A Solution For Everyone
PEL Accessory Kits
The Chauvin Arnoux PEL range come in a variety of pre-packed kits, each designed for a different user. Whether you're an electrical contractor or business owner, we have a kit full of the accessories you'll need for the job. If you're unsure, just get in touch and we can suggest the best option, or even craft you a bespoke kit.
Why Buy a Chauvin Arnoux PEL from Us?
PASS Ltd have 20+ years of knowledge in the electrical industry and are well experienced in all things power, as such we can offer you:
- Advice from our Chauvin Arnoux trained team
- Peace of mind as the leading Chauvin Arnoux distributor
- On-site demonstrations (model dependent)
- Wide range of accessories and software
- Unbeatable offers on the C.A PEL Series
Need advice? Contact us or call 01642 931329.
Top 5 Reasons for Logging
PEL51 for Electricians
Chauvin Arnoux PEL FAQs
Does the PEL range come with software?
Yes, power and energy loggers from Chauvin Arnoux come with free PEL Transfer software. DataView is available, but it is, generally, an additional fee.
Will a PEL Power-Energy Logger save me money?
To measure the financial benefit of upgrading your system, an energy load study is key. This compares the efficiency of your old system against the new one. By analysing load data both before and after installation, we can build a comprehensive picture of the energy savings achieved, providing a clear Return on Investment (ROI) assessment. The PEL104 and PEL106 come with a built in energy cost calculation.
Can I use a Chauvin Arnoux PEL to do a load study?
Yes, the PEL50 and PEL100 Series can be used to analyse a specific system's energy consumption patterns and demands. Utilise data acquisition, statistical analysis, and engineering principles to understand load profile, analyse power quality, and identify optimisation opportunities.
How can I interface with the PEL Series?
The Chauvin Arnoux PEL 51/52 are Wi-Fi only, PEL 102/103 ethernet only and PEL 104/106 can do both Wi-fi and ethernet. All PEL models can connect via USB and Bluetooth.
Are the Chauvin Arnoux PEL series TRMS?
All PEL models are capable of TRMS current and voltage measurements.
Can IT network security get in the way?
Without an IRD (Internet Relay Device) a network administrator may need to help. However, the DataView data processing platform from Chauvin Arnoux makes it easy for users to access all the data from their PEL50 and PEL100 power and energy loggers using a PC or tablet. This is possible thanks to an Ethernet link with an IRD server hosted by Chauvin Arnoux and connected to the internet. This functionality is available to all owners of PEL50 & PEL100 power and energy loggers.
Helpful Blogs
Here are some things to consider when choosing a Chauvin Arnoux PEL Power-Energy Logger:
Introducing Portable Energy Loggers: What Are PELs and Do You Need One?
Chauvin Arnoux Names 4 Tests Electricians Can Perform to Increase Profits
Walking and Watching: Are These Really Chauvin Arnoux's Top Tips for Saving Energy?
Ways Businesses Can Save Energy: A White Paper
Spot the Signs and Symptoms of Power Quality Faults
Is Power Analysis in Your Future?
For advice and to order:
Call 01642 931329