Megger RCD Testers - RCDT & LRCD Series
Discover the best Megger RCD testers for dependable electrical testing. Enhance safety and efficiency in your projects. Read the essential guide now!
Find out more about Megger RCD Testers - RCDT & LRCD Series below.

- RCD trip time tests, selective breakers & DC breakers
- IP54 weatherproofing
- Safety interlock, test leads, LED connection indicators, 3-phase safe and testing inhibit

- Suitable for use with a wide range of different RCD types
- Advanced automatic testing and ramp testing procedures
- Built into its own protective carrying case with foldable lid

- Tests DC, standard and selective RCDs
- Stores up to 1000 tests on the device
- Safe for three-phase testing

- Non-tripping Loop test
- 3 wire low current non-tripping loop test provides measurements from 0.01 ohms to 2 kohms
- Auto-ranging tests

- Non-trip loop tester
- RCD testing from 10 mA to 1000 mA
- Extremely easy and safe to use

- Impedance of phases and neutral conductors up to the 10th harmonic
- Automatically switches between measurement points
- 1kA test current

- Measure the grid impedance of LV grid systems
- Multi-phase measurements with automatic test point switching
- Memory storage and transfer to PC
About Megger RCD Testers
Megger RCD (Residual Current Device) testers are instruments designed to evaluate the functionality and safety of RCDs within electrical installations. RCDs are crucial for protecting individuals from electric shocks by detecting and disconnecting circuits when an imbalance between live and neutral currents occurs. Regular testing with devices like Megger's RCD testers ensures these protective mechanisms operate correctly, maintaining electrical safety standards.
Key Functions
- Trip Time Testing: Measures the time it takes for an RCD to disconnect the circuit upon detecting a fault, ensuring it operates within specified safety parameters.
- Trip Current Testing (Ramp Testing): Determines the exact current level at which the RCD trips, verifying its sensitivity and proper calibration (Megger RCDT320 and above).
- Auto Testing Sequences: Performs a series of tests automatically, including multiple trip time and current assessments, streamlining the verification process (Megger RCDT320, RCDT330 and LRCD220).
- Testing of Various RCD Types: Accommodates standard, Type A, selective, and programmable RCDs, ensuring comprehensive testing across various installations.
- Combined Testing: Loop and RCD testing in one unit (LRCD series)
Key Specifications
As a whole, the Megger RCD tester range include the following (individual models may differ):
- Supply voltage measurement: 200V to 280V (LRCD210). 100V to 280V (RCDT310 & LRCD220). 50V to 280V (RCDT320 & RCDT330). 45 Hz to 65.
- Testing of standard RCD: 30mA, 100mA, 300mA, 500mA on all models. 1000mA (LRCD220)
- Basic RCD trip time testing: 1/2 x I, 1 x I, and 5 x I
- Touch voltage display with selectable limits
- 3 Phase safe Enables testing on 110 V centre tapped supplies (RCDT320 & RCDT330)
- Internal memory with USB download capability (RCDT330)
- Polarity Selection: 0? and 180? test options
- IP54 weatherproof rating
- CAT III 300V safety rating
- Clear LCD display
- Battery status indication
- Fuse blown indicator (RCDT models)
- Backlit screen for low-light environments
Applications
Applications span across various sectors, including domestic electrical installations, industrial facilities, commercial buildings, educational institutions, healthcare facilities, construction sites, property maintenance, and electrical contracting. They are used for:
- Electrical Installation Testing: Essential for electricians and maintenance personnel to verify that RCDs in residential, commercial, and industrial settings function correctly, ensuring occupant safety.
- Compliance Verification: Assists in meeting regulatory standards and safety codes by providing documented proof of RCD performance during inspections and certifications.
- Troubleshooting: Aids in diagnosing issues within electrical circuits by confirming whether RCDs are operating as intended or if replacements are necessary.