Detect malfunctions in low voltage grids early using the Megger NIM 1000 Network Impedance Meter. Equipped with a 1kA test current, the Megger NIM 1000 Network Impedance Meter triggers load-sensitive and neutral faults, finds weak contacts, and exposes hidden flaws. It can be used to assess the grid’s current capacity under real-life conditions and conduct tests on cables, power supply lines, and bus bars.
Capable of measuring the impedance of phases and neutral conductors up to the 10th harmonic, the Megger NIM 1000 Network Impedance Meter can be used to assess how LV grids perform under load. Multi-phase measurement allows the impedance of neutral conductors to be calculated (depending on the grounding conditions of the grid) enabling you to identify faults that could lead to severe safety issues. When conducting multi-phase measurements, the Megger NIM 1000 Network Impedance Meter automatically switches between measurement points making the meter easy to operate.
Its ergonomic design, compact size, and bright colour display also ensure that the Megger NIM 1000 Network Impedance Meter is simple to use especially in demanding LV utility environments.
The Megger NIM 1000 Network Impedance Meter is an accurate, versatile, and practical instrument that can be used to determine the correct dimensioning of installations, ensure consistently good power quality, and prevent downtime.
Megger NIM 1000 Network Impedance Meter Key Features
- Precise, versatile, easy-to-use impedance meter with a 1kA test current
- Detect malfunctions in low-voltage grids early
- Triggers load-sensitive and neutral faults
- Detects weak contacts
- Exposes hidden flaws
- Asses the grid’s current capacity under real-life conditions
- Conduct tests on cables, power supply lines, and bus bars
- Measure the impedance of phases and neutral conductors up to the 10th harmonic
- Assess how LV grids perform under load
- Multi-phase measurement allows the impedance of neutral conductors to be calculated
- Automatically switches between measurement points
- Ergonomic
- Compact
- Bright colour display
- Easy to use especially in demanding LV utility environments
- Accurate, versatile, and practical instrument
- Determine the correct dimensioning of installations
- Ensure consistently good power quality
- Prevent downtime
What’s Included?
- Megger NIM 1000 Network Impedance Meter
- Power Kelvin Clamps with 3m Connection Leads
- Schuko Adapter
- 2GB USB Stick
- Set of Spare Fuses
*Please note this item has to be purchased together with the Megger 1006123 NIM 1000-Z Equipment Set and Megger 2005383 NIM 1000-A-UK Adapter at additional costs.*
Megger NIM 1000 Network Impedance Meter Technical Specifications
Test current range | 80 A … 1000 A (adjustable) |
Maximum current Imax (peak; Imax depends on the grid impedance) | ≤ 1000 A at 400 V |
≤ 600 A at 230 V | |
≤ 300 A at 115 V | |
Test Parameter | |
Z | Impedance (value and phase) |
R | Resistance (real part) |
X | Reactance (imaginary part) |
ZPEN | Impedance value PEN (calculated) |
Urms | RMS voltage |
Imax | Max. test current |
Is | Short circuit current |
Skv | Continuous short circuit power |
f | Net frequency |
VD | Voltage drop at nominal connected power (in %) |
Pmax | Max. connected power at nominal voltage drop |
Note | Z, R, X, and ZPEN are displayed for the power frequency up to the 10th harmonic (phase-N, phase-phase) |
Input voltage (serves as supply voltage) | 90 V ... 480 V, 50/60 Hz (at test clamps) |
90 V … 230 V, 50/60 Hz (at power outlet) | |
Operational accuracy B (acc. to EN 61557-3) | 3% ± 1 digit (at sufficient test current) |
Test range (at the above accuracy) | 10 mΩ ... 5 Ω (230 V / 400 V) |
10 mΩ ... 2.5 Ω (115 V) | |
Resolution | 1 mΩ |
Test category | 300V CAT IV |
Safety functions | Temperature monitoring, fused clamps |
Display | Sunlight-readable 5,7“ TFT; 640 x 480 Pixel |
Memory | Min. 1000 test records |
Interface | USB 2.0 |
Operating temperature | -20 °C … 55 °C |
-4 °F … 131 °F | |
Storage temperature | -30 °C … 70 °C |
-22 °F … 158 °F | |
Operating humidity | max. relative humidity 93% at 30˚C |
IP-Protection | IP 50 (lid open) |
IP 53 (lid closed) | |
Protection class | Insulated acc. to protection class II |
Weight | 10 kg |
Dimensions | 410 x 175 x 335 mm 16.1 in. x 6.9 in. x 13.2 in. |