The Megger LRCD210 is a combined loop and RCD tester designed to make life easier when performing test procedures.
The LRCD210 is the mid-range model available in the LRCD series, and it is capable of carrying out three phase safe non-trip loop testing 1/2I, I, and 5I RCD testing for standard, selective and DC RCDs. It is most suited towards UK domestic installers and adheres to all Part P requirements.
Megger has specially constructed this tester to withstand all common stresses including weatherproofing with IP54 ratings, a protective screen, and a tough armored casing to stop bumps, knocks, and drops from harming your tester.
When performing tests on RCDS the Megger LRCD210 is guaranteed not to trip the RCD. It also performs 3 wire low current non-tripping loop tests.
Voltage Measurements | 0 V - 500 V |
Voltage Accuracy | ±2% ±2 digits |
Frequency Measurement Range | 25Hz to 450Hz |
Frequency Accuracy | 25.0Hz to 199.9Hz ±0.1Hz 200Hz to 450Hz ±1Hz |
Phase Rotation Indicator (LRCD220 only) | Three wire identification of phase rotation. |
Frequency | 45Hz to 65Hz |
Loop Testing | Loop ranges (to EN 61557-3) |
No-Trip Loop Test (3 Wire, Line To Earth) | LRCD200/210 200V - 280 V 45Hz to 65Hz LRCD220 100V - 280 V 45Hz to 65Hz |
Nominal Test Current | 15 mA |
Loop Accuracy | 0.01 ½ - 9.99 ½ (±5% ±0.03 ½) 10.0 ½ - 99.9 ½ (±5% ±0.5 ½) 100 ½ - 999 ½ (±5% ±5 ½) 1.00 k½ - 2.00 k½ (±5% ±30 ½) |
Hi Current Line/Earth Loop Test (2 Wire, LRCD220 Only) | Yes |
Supply | 100 V - 480 V |
Nominal Test Current | 15 mA to 2.4 A |
Loop Accuracy | 0.01½ - 9.99 ½ (±5% ±0.03 ½) 10.0½ - 99.9 ½ (±5% ±0.5 ½) 100½ - 999 ½ (±5% ±5 ½) 1.0 k½ - 2.00 k½ (±5% ±30 ½) |
Line/Line (LRCD220 Only) Supply | 100 V - 480 V 45Hz to 65Hz |
Prospective Fault Current (PSCC) | Prospective fault current = Nominal supply voltage/Loop resistance Accuracy is derived from loop test 1 A - 199 A 1 A resolution 0.20 kA - 1.99 kA 10 A resolution 2.0 kA - 19.9 kA 100 A resolution |
RCD Testing | RCD Test Ranges (to EN61557-6) LRCD200/210 10mA, 30mA,100mA, 300mA, 500mA LRCD220 10mA, 30mA,100mA, 300mA, 500mA, 1000mA |
Supply Voltage | LRCD200/210 = 200 V - 280 V 45Hz to 65Hz LRCD220 = 100 V - 280 V 45Hz to 65Hz |