*** The Martindale NC2 Non-contact Voltage Tester replaces Martindale’s now obsolete VT2 Non-Contact Voltage Indicator. ***
The Martindale NC2 Non-contact Voltage Tester can be used to detect the presence of voltages between 200V and 1000V.
This tool is suitable for tracing live circuits in cable containments and for detecting voltages in sockets and junction boxes. This is because the Martindale NC2 Non-contact Voltage Tester can indicate the presence of a voltage at approximately 4mm from a conductor at 240V.
When the Martindale NC2 Non-contact Voltage Tester detects a voltage, it will issue a buzzer alert and its clear tip will be illuminated by a red LED.
The Martindale NC2 Non-contact Voltage Tester is optimised for detecting voltages in 230V and three-phase supplies. It can also be used to differentiate between Live and Neutral wires and can detect blown fuses.
This tool has been ergonomically designed and to this end features an extended probe construction which facilitates easy access. It also includes an LED torch for conducting inspections in low light. Furthermore, the Martindale NC2 Non-contact Voltage Tester features a low battery indicator and a power-on LED pulse.
Further to this, the pen-shaped Martindale NC2 Non-contact Voltage Tester with clip can be easily carried in a pocket or tool belt.
The Martindale NC2 Non-contact Voltage Tester is an ergonomic, easy-to-use and effective voltage detector.
Martindale NC2 Non-contact Voltage Tester Key Features
- Replaces Martindale’s VT2 Non-contact Voltage Indicator
- Detect the presence of voltages between 200V and 1000V
- Trace live circuits in cable containments
- Detect voltages in sockets and junction boxes
- Indicates the presence of voltages at approximately 4mm from a conductor at 240V
- Audible and visual indication
- Buzzer alert
- Red LED illuminates the clear tip
- Optimised for detecting voltages in 230V and three-phase supplies
- Can be used to differentiate between Live and Neutral wires
- Can be used to detect blown fuses
- Extended probe design for easy access
- LED torch for conducting inspections in low light
- Low battery indicator
- Power-on LED pulse
- Pen-shaped with clip for carrying in a pocket or on a tool belt
- An ergonomic, easy-to-use and effective voltage detector
What’s Included?
- Martindale NC2 Non-contact Voltage Tester
Martindale NC-Series Non-contact Voltage & Solenoid Testers Comparison Chart
NC1 | NC2 | NC3 | NC4 | |
---|---|---|---|---|
AC Voltage Range | - | 200-1000V | 200-1000V |
12-1000V 50-1000V |
Frequency Range | - | 40-400Hz | 40-400Hz | 40-400Hz |
Magnetic Field Detection | >10mT | - | >10mT | - |
LED Indication | Yellow LED | Red LED | Yellow/ Red LED | Red LED |
Audible Indication | Yes | Yes | Yes | Yes |
Power on Pulse LED | Yes | Yes | Yes | Yes |
Low Battery Indication | Yes | Yes | Yes | Yes |
Auto Power Off | Yes | - | Yes | Yes |
LED Torch | Yes | Yes | Yes | Yes |
Martindale NC-Series Non-contact Voltage & Solenoid Testers Technical Specifications
NC1 | NC2 | NC3 | NC4 | |
---|---|---|---|---|
Electrical | ||||
Maximum voltage | - | 1000V AC rms | ||
Voltage sensitivity range | - | 200 to 1000V AC rms | 200 to 1000V AC rms |
12 to 1000V AC rms 50 to 1000V AC rms (default range) |
Frequency range | - | 40 to 400Hz | ||
Magnetic | ||||
Magnetic field sensitivity | >10mT | - | >10mT | - |
Environmental | ||||
Temperature & Humidity (Operating & Storage) | 0°C to 40°C ≤ 80% R.H. | |||
Altitude | up to 2000m | |||
Pollution Degree | 2 | |||
General | ||||
Power | 2 x 1.5V AAA alkaline batteries (IEC LR03, NEDA 24A) | |||
Dimensions | 158(L) x 20(W) x 27(D) | |||
Weight | 55g | |||
Safety | ||||
Conforms to | BS EN 61010-1:2010 CAT IV 1000V Class II, Double insulation | |||
IP Rating | IP40 to BS EN 60529 | |||
EMC | ||||
Conforms to | BS EN 31326-1 |