*** The Martindale NC2 Non-contact Voltage Tester replaces Martindale’s now obsolete VT2 Non-Contact Voltage Indicator. ***
The Martindale NC2 Non-contact Voltage Tester can be used to detect the presence of voltages between 200V and 1000V.
This tool is suitable for tracing live circuits in cable containments and for detecting voltages in sockets and junction boxes. This is because the Martindale NC2 Non-contact Voltage Tester can indicate the presence of a voltage at approximately 4mm from a conductor at 240V.
When the Martindale NC2 Non-contact Voltage Tester detects a voltage, it will issue a buzzer alert and its clear tip will be illuminated by a red LED.
The Martindale NC2 Non-contact Voltage Tester is optimised for detecting voltages in 230V and three-phase supplies. It can also be used to differentiate between Live and Neutral wires and can detect blown fuses.
This tool has been ergonomically designed and to this end features an extended probe construction which facilitates easy access. It also includes an LED torch for conducting inspections in low light. Furthermore, the Martindale NC2 Non-contact Voltage Tester features a low battery indicator and a power-on LED pulse.
Further to this, the pen-shaped Martindale NC2 Non-contact Voltage Tester with clip can be easily carried in a pocket or tool belt.
The Martindale NC2 Non-contact Voltage Tester is an ergonomic, easy-to-use and effective voltage detector.
NC1 | NC2 | NC3 | NC4 | |
---|---|---|---|---|
AC Voltage Range | - | 200-1000V | 200-1000V |
12-1000V 50-1000V |
Frequency Range | - | 40-400Hz | 40-400Hz | 40-400Hz |
Magnetic Field Detection | >10mT | - | >10mT | - |
LED Indication | Yellow LED | Red LED | Yellow/ Red LED | Red LED |
Audible Indication | Yes | Yes | Yes | Yes |
Power on Pulse LED | Yes | Yes | Yes | Yes |
Low Battery Indication | Yes | Yes | Yes | Yes |
Auto Power Off | Yes | - | Yes | Yes |
LED Torch | Yes | Yes | Yes | Yes |
NC1 | NC2 | NC3 | NC4 | |
---|---|---|---|---|
Electrical | ||||
Maximum voltage | - | 1000V AC rms | ||
Voltage sensitivity range | - | 200 to 1000V AC rms | 200 to 1000V AC rms |
12 to 1000V AC rms 50 to 1000V AC rms (default range) |
Frequency range | - | 40 to 400Hz | ||
Magnetic | ||||
Magnetic field sensitivity | >10mT | - | >10mT | - |
Environmental | ||||
Temperature & Humidity (Operating & Storage) | 0°C to 40°C ≤ 80% R.H. | |||
Altitude | up to 2000m | |||
Pollution Degree | 2 | |||
General | ||||
Power | 2 x 1.5V AAA alkaline batteries (IEC LR03, NEDA 24A) | |||
Dimensions | 158(L) x 20(W) x 27(D) | |||
Weight | 55g | |||
Safety | ||||
Conforms to | BS EN 61010-1:2010 CAT IV 1000V Class II, Double insulation | |||
IP Rating | IP40 to BS EN 60529 | |||
EMC | ||||
Conforms to | BS EN 31326-1 |