Sonel MPI-540-PV-IRM1 Solar Multi-function Meter & Radiation Meter

All Sonel Products
  • Multi-function Meter
  • Radiation and Temperature Meter
SKU
MPI-540-PV-IRM1
MPN
MPI-540-PV-IRM1

Read More

View All Solar Installation Testers

The Sonel MPI-540-PV measures critical parameters on the DC and AC sides of PV systems in full compliance with the EN 62446 standard. It automatically recalculates readings to Standard Test Conditions (STC).

The MPI-540-PV includes Auto-mode testing for residual current devices (RCDs) and manufacturer-configured autotests. Users can even create and save custom test sequences to match specific requirements. Please visit MPI-540-PV for further information.

The Sonel IRM-1 complements the MPI-540-PV by providing precise environmental data during PV system evaluations. It measures solar irradiance along with panel surface and ambient temperatures. For more details, please visit our IRM-1 listing.

Unboxing Sonel MPI-540-PV Solar

What's Included?

  • MPI-540-PV solar multi-function meter
  • IRM-1 solar radiation and temperature meter
  • IRM-1 mounting & measuring set
  • 5 V power supply with USB 2.0 output and a detachable micro-USB cable
  • LORA-S1 adapter for data transmission
  • PVM-1 adapter
  • PVM-1 adapter
  • WS-03 adapter with START button with UNI-Schuko plug (CAT III 300 V)
  • C-PV clamp
  • Adapter for C-PV clamp
  • Three F-3A flexible clamps (Ø 120 mm)
  • Test lead 1.2 m (banana plugs) black
  • Test lead 1.2 m (banana plugs) red
  • Test lead 1.2 m (banana plugs) blue
  • Test lead 1.2 m (banana plugs) yellow
  • Crocodile clip 1 kV 20 A black
  • Crocodile clip 1 kV 20 A red
  • Crocodile clip 1 kV 20 A blue
  • Crocodile clip 1 kV 20 A yellow
  • Pin probe 1 kV (banana socket) red
  • Pin probe 1 kV (banana socket) blue
  • Pin probe 1 kV (banana socket) yellow
  • Test lead 15 m, blue (on a reel)
  • Test lead 30 m, red (on a reel)
  • Two Earth contact test probes (rod), 30 cm
  • Voltage adapter with M4/ M6 thread (set of 4 pcs.)
  • USB cable
  • 4 GB microSD card
  • Main cable with IEC C7 plug
  • Z-7 power supply
  • Cable for battery charging from car cigarette lighter socket (12 V)
  • Li-Ion battery 11.1 V 3.4 Ah
  • Touchscreen pen
  • L-2 hanging straps (set)
  • L-19 backpack
  • Program for handling PQM Series Power Quality Analysers MPI-540
  • Free software to transfer data from meters
  • Factory calibration certificate - MPI-540-PV
  • Factory calibration certificate - IRM-1
£4,620.00
£5,544.00 inc vat
Free Delivery*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
4620 Reward Points 60 Days Return

Ask An Expert
Price Match
Technical Information
Specification
MPI-540-PV | Specifications - Electrical Installation Parameters
Measurement Functions Measurement Range Display Range Resolution Accuracy
Fault Loop Impedance
Fault loop ZL-PE, ZL-N, ZL-L 0.13 Ω…1999.9 Ω acc. to IEC 61557 0.00 Ω…1999 Ω from 0.001 Ω ±(5% m.v. + 30 digits)
Fault loop ZL-PE in RCD mode from 0.50 Ω…1999 Ω acc. to IEC 61557 0.00 Ω…1999 Ω from 0.01 Ω from ±(6% m.v. + 5 digits)
Measurements of RCD Parameters
RCD tripping test and measurement of tripping time tA, measuring current 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn
General and short-time delay RCD 0 ms…300 ms 0 ms…300 ms 1 ms from ±(2% m.v. + 2 digits)
Selective RCD 0 ms…500 ms 0 ms…500 ms 1 ms from ±(2% m.v. + 2 digits)
Measurement of RCD tripping current IA measuring current 0 0.2 IΔn…2.0 IΔn
For sinusoidal residual current (AC type) 3.3 mA…1000 mA 3.3 mA…1000 mA from 0.1 mA ±5% IΔn
For unidirectional residual current and unidirectional with the 6 mA DC bias (type A) 3.5 mA…700 mA 3.5 mA…700 mA from 0.1 mA ±10% IΔn
For direct residual current (type B) 2.0 mA…1000 mA 2.0 mA…1000 mA from 0.1 mA ±10% IΔn
Earth Resistance
3- and 4-pole method from 0.50 Ω…1.99 kΩ acc. to IEC 61557-5 0.00 Ω…1,99 kΩ from 0.01 Ω from ±(2% m.v. + 3 digits)
3-pole + clamp method 0.00 Ω…1.99 kΩ 0.00 Ω…1.99 kΩ from 0.01 Ω from ±(2% m.v. + 4 digits)
2-clamp method 0.00 Ω…99.9 kΩ 0.00 Ω…99.9 kΩ from 0.01 Ω from ±(10% m.v. + 4 digits)
Resistance-to-earth 0.0 Ω m…99.9 kΩm 0.0 Ωm…99.9 kΩm from 0.1 Ωm Depending on the accuracy of the RE measurement
Insulation Resistance
Measuring voltage 50 V 50 kΩ…250 MΩ acc. to IEC 61557-2 0 kΩ…250 MΩ from 1 kΩ from ±(3% m.v. + 8 digits)
Measuring voltage 100 V 100 kΩ…500 MΩ acc. to IEC 61557-2 0 kΩ…500 MΩ from 1 kΩ from ±(3% m.v. + 8 digits)
Measuring voltage 250 V 250 kΩ…999 MΩ acc. to IEC 61557-2 0 kΩ…999 MΩ from 1 kΩ from ±(3% m.v. + 8 digits)
Measuring voltage 500 V 500 kΩ…2.00 GΩ acc. to IEC 61557-2 0 kΩ…2.00 GΩ from 1 kΩ from ±(3% m.v. + 8 digits)
Measuring voltage 1000 V 1000 kΩ…4.99 GΩ acc. to IEC 61557-2 0 kΩ…9.99 GΩ from 1 kΩ from ±(3% m.v. + 8 digits)
Resistance of Protective Conductors and Equipotential Bondings
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current 0.12 Ω…400 Ω acc. to IEC 61557-4 0.00 Ω…400 Ω from 0.01 Ω ±(2% m.v. + 3 digits)
Measurement of resistance with low current 0.0 Ω…1999 Ω 0.0 Ω…1999 Ω from 0.1 Ω ±(3% m.v. + 3 digits)
Light intensity
Measurement in luxes (lx) 0 lx…399.9 klx 0 lx…399.9 klx from 0.001 lx from ±(2% m.v. + 5 digits)
Measurement in feet-candles (fc) 0 fc…39.99 kfc 0 fc…39.99 kfc from 0.001 fc from ±(2% m.v. + 5 digits)
Phase Sequence Indication In the same direction (correct), opposite direction (incorrect), UL-L voltage: 95 V…500 V (45 Hz…65 Hz)
m.v. - measured value
MPI-540-PV | Specifications - 3-phase Power Quality Recorder
Designed to Work with Mains Nominal frequency:
50/60 Hz
Nominal voltage:
64/110 V
110/190 V
115/200 V
127/220 V
220/380 V
230/400 V
240/415 V
254/440 V
290/500 V
DC networks
Supported Systems Single-phase
Split-phase with common N
Three-phase - WYE with and without N conductor
Three-phase - Delta
Parameter Measuring range Max. resolution Accuracy
Alternating Voltage (TRMS) 0.0…500 V 0.01% Unom ±0,5% Unom
Alternating Current (TRMS) depending on clamp* 0.01% Inom ±2% m.v. If m.v. ≥ 10% Inom, ±2% Inom if m.v. < 10% Inom, (error does not account for clamp error)
Frequency 40.00…70.00 Hz 0.01 Hz ±0.05 Hz
Active, Reactive, Apparent and Distortion Power depending on configuration (transducers, clamps) 4 significant digits depending on configuration (transducers, clamps)
Active, Reactive and Apparent Energy depending on configuration (transducers, clamps) 4 significant digits as power error
Cosφ and Power Factor (PF) 0.00…1.00 0.01 ±0.03
Harmonics
Voltage As for alternating voltage, True RMS As for alternating voltage, True RMS ±5% m.v. If m.v. ≥ 3% Unom, ±0,15% Unom if m.v. < 3% Unom
Current As for alternating current, True RMS As for alternating current, True RMS ±5% m.v. If m.v. ≥ 10% Unom, ±0,5% Unom if m.v. < 10% Unom
THD
Voltage 0.0…100.0% (relative to RMS value) 0.1% ±5%
Current 0.0…100.0% (relative to RMS value) 0.1% ±5%
Unbalance Factor 0.0…10.0% 0.1% ±0.15% (absolute error)
*
F-1A, F-2A, F-3A clamp: 0…3000 A AC (10 000 Ap-p)
C-4A clamp: 0…1200 A AC
C-5A clamp: 0…1000 A AC/0…1400 A DC
C-6A clamp: 0…12 A AC
C-7A clamp: 0…100 A AC
MPI-540-PV | AC Current Measurement (True RMS) with Clamp
C-4A C-5A C-6A C-7A F-1A F-2A F-3A
Rated Current 1200 A AC 1000 A AC
1400 A DC
12 A AC 100 A AC 3000 A AC 3000 A AC 3000 A AC
Frequency 30 Hz…10 kHz DC…5 kHz 40 Hz…10 kHz 40 Hz…1 kHz 40 Hz…10 kHz 40 Hz…10 kHz 40 Hz…10 kHz
Max. Diameter of Measured Conductor 52 mm 39 mm 20 mm 24 mm 380 mm 250 mm 140 mm
Minimum Accuracy ≤0,5% ≤1,5% ≤1% 0,5% 0.5% 0.5% 0.5%
Battery Power - - - - - -
Lead Length 2.2 m 2.2 m 2.2 m 3 m 2.5 m 2.5 m 2.5 m
Measurement Category IV 300 V IV 300 V IV 300 V III 300 V IV 600 V IV 600 V IV 600 V
Ingress Protection IP40 IP40 IP40 IP40 IP67 IP67 IP67
MPI-540-PV | Specifications - Photovoltaic Installation Parameters
Measurement Functions Display Range Resolution Accuracy
Open Circuit Voltage UOC 0.0 Ω…1000 V from 0.1 V from ±(3% m.v. + 2 digits)
Short Circuit Current ISC 0.00 Ω…20.00 A 0.1 A ±(3% m.v. + 0.10 A)
IRM-1 | Specifications
Parameter Measurement range Display range Resolution Accuracy
Irradiance
Measurement in W/m2 100 W/m2 …1400 W/m2 0 W/m2 …1400 W/m2 1 W/m2 ±(5% m.v. + 2 digits)
Measurement in BTU/ft2h 32 BTU/ft2h…444 BTU/ft2h 0 BTU/ft2h…444 BTU/ft2h 1 BTU/ft2h ±(5% m.v. + 2 digits)
PV and Ambient Temperature
Measurement in °C -20.0°C…100.0°C -20.0°C…100.0°C 0.1°C ±(1% m.v. + 5 digits)
Measurement in °F -4.0°F…212.0°F 4.0°F…212.0°F 0.1°F ±(1% m.v. + 5 digits)
Inclination Angle -90°…+90° -90°…+90° ±2°
Position Direction - Compass 0°…360° 0°…360° ±5°
m.v. - measured value
Document Downloads
Sonel IRM-1 Solar Radiation and Temperature Meter Datasheet Datasheet
Sonel MPI-540-PV Solar Multi-function Meter Datasheet Datasheet
Sonel MPI-540-PV Solar Multi-function Meter User Manual Manual/Guide
Additional Information
SKU
MPI-540-PV-IRM1
Manufacturer Part Code
MPI-540-PV-IRM1

Customer Reviews

 
Sonel MPI-540-PV-IRM1 Solar Multi-function Meter & Radiation Meter
£4,620.00
£5,544.00 inc vat
£4,620.00
£5,544.00 inc vat