Free Beanie Hat. Spend £250+ (ex VAT) View
All Megger Products

Megger PAT410 Downloadable Portable Appliance Tester

SKU
1000-745
Rating:
0%
(0)
Reward Points
:
1178
£1,413.60 £1,178.00
Free UK Delivery*
Choose a Special Offer
  •  PASS Training USB with Exam, Pass & Fail Labels (PTPROMO7)
    PASS Training Online Course with Exam, Pass & Fail Labels
    FREE
    £93.27
  • PASS Training Online Course with Exam, Pass & Fail Labels SKU: (PTPROMO7)
    FREE
    £93.27
     PASS Training USB with Exam, Pass & Fail Labels (PTPROMO7)
  • PASS The Complete Guide to EET (PAT) Testing Cover
    PASS The Complete Guide to EET (PAT) Testing, 5th Edition
    FREE
    £24.99
  • PASS The Complete Guide to EET (PAT) Testing, 5th Edition SKU: (PASS-PAT-HB)
    FREE
    £24.99
    PASS The Complete Guide to EET (PAT) Testing Cover
    • Covers 5th Edition IET Code of Practice updates
    • 129 page in-depth PAT/EET guide
    • Easy to understand with lots of examples
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
FREE Accessory Bundle
Megger PAT410 PAT Kit
Free PAT Reference Card

Megger PAT410 Downloadable Portable Appliance Tester

Looking for a reliable PAT tester with downloadable memory storage, allowing you to store all your results, then catalogue them on a PC? The Megger PAT410 is an excellent choice. The entry-level model in Megger's series of fully downloadable PAT testers, the PAT410 is designed for PAT testing in any application. The tester can be used in hotels, public houses, schools, colleges, nurseries, shops, offices, theatres, banks, restaurants, cafes, sports and leisure facilities and absolutely anywhere where you'll be testing a large amount of appliances and need to store the appliance ID numbers alongside their testing results.

Megger's Portable Appliance Tester (EET) makes cataloguing PAT testing results as simple as possible. The tester can store up to 10,000 individual testing records and - thanks to a built-in QWERTY keyboard - making amendments to your appliance notes is extremely simple. Done with testing? Insert a USB stick into the tester, download to it, then plug into your PC and view your results in either CSV format (compatible with Microsoft Excel) or buy SIMPLYPATS software (sold separately) for full database asset management, certificate generation and much more.

Designed to help you speed up testing, with the QWERTY keyboard and 5 soft keys for direct access to your frequently used functions. Automatic testing routines also help you to speed up your tests, or you can use the manual mode to configure your test times and select different appliance pass limits as needed.

This PAT tester is suitable for checking a wide variety of appliances, including class I and II, IT equipment and power leads (including extension leads). The PAT Tester will carry out all tests as defined in the IET Code of Practice, including Earth bond/continuity, insulation (at 250 and 500V), substitute/differential/touch current leakage tests, operational checks and also performs specific earth bond, insulation, polarity and portable RCD tests on extension leads.

It also features a full-colour graphical display, built-in lead storage pouch and a fuse check function.

Note: although the PAT410 does not include a 110V socket as the PAT420 and PAT450 do, it can still be used for 110V testing by using an appropriate 110V adapter kit.

Testing Capabilities

  • 250 & 500V insulation tests
  • 200mA continuity test
  • Differential
  • Substitute
  • Touch current earth leakage tests
  • Operational VA test
  • Portable RCD testing
  • Extension lead and power cord tests

Videos

How to use the Megger PAT400 PAT Tester Series

Key Features

  • Powerful downloadable PAT tester recommended for use by professional users
  • 10,000 record internal memory with easy download via USB connection (or plugin a USB stick and download onto that)
  • Test results can be exported in Excel format, or exported into SIMPLYPATS software (sold separately) for full database management of customers, results and creation of certificates
  • Built-in QWERTY keyboard makes it easy to make amendments to all testing logs
  • 230V internal supply for testing 230V appliances; it can also be used to test 110V appliance using a set of optional adapters
  • Large size 5.7" VGA backlit full-colour screen
  • 200mA earth bond/continuity test with bond lead nulling
  • Insulation testing at 250V and 500V
  • Substitute, differential and touch current alternative leakage tests
  • Earth bond, insulation, polarity and portable RCD extension lead tests
  • Low weight - lightest model in the PAT400 series
  • Automatic test routines save you time and effort when testing
  • Take full control over tests with the manual mode - easily adjust test times and select the pass limit
  • Fuse check function
  • Built-in lead storage pouch

What's Included?

  • Megger PAT410 Downloadable PAT Tester
  • Printed Quick Start Guide
  • Full User Guide on CD
  • Calibration Certificate
  • Continuity/Earth Bond Lead + Probe (Black)
  • Extension Lead Adaptor (13A)
  • Carrying Case
  • Plug Adaptor (IEC C6 - C13)
  • Screen Protector

PASS Exclusive Megger PAT410 PAT Testing Kits

Why buy the standard tester when you can get one of these amazing value kits instead?

You'll get everything you get as standard, plus all of the accessories you'll need when PAT testing!

This table outlines exactly what's in each kit.

Item    PAT Essentials Kit (Bundle 1) PAT Business Kit (Bundle 2) PAT Premium Kit (Bundle 3) PAT Elite Printer Kit (Bundle 4)

UNI-T UT07A Socket Tester

Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it!

(socket tester may vary depending on current stock)

 Yes  Yes Yes Yes

CK Tools AV05050 Screwdriver Set

This bundle pack includes a set of 5 fully insulated electrical screwdrivers which are suitable for live electrical work to 1000V

Yes Yes Yes  Yes

PAT Testing Training DVD + Online Examination for 1 Person

Not trained to perform PAT testing? With our training DVD, you can learn from your workplace or at home how to PAT test!

The course is based on our own full, tutor-lead PAT Competency Course and includes access to our online examination for 1 person.

Yes Yes Yes  Yes

PASS PAT Testing Handbook

A comprehensive, extremely detailed guidebook with useful information, diagrams, pictures and case studies related to PAT testing.

The book breaks down everything from requirements to actually performing testing and is an essential for any PAT tester

Yes Yes Yes  Yes

Microwave Leakage Detector

It's common practice to check microwave radiation levels while you're PAT testing - use this portable, easy-to-use microwave leakage detector to do so

Yes Yes Yes  Yes

IEC Adapter Set

A special bundle pack with three IEC adapters, allowing you to use your PAT tester with various types of IEC cables and power supplies

Yes Yes Yes  Yes

110V Adapter Set

Use these two 110V connector leads to connect your PAT tester to 110V equipment commonly found on construction sites and similar applications

Yes Yes Yes  Yes

Passed PAT Testing Labels

A PAT essential! We include two 500 label rolls in your purchase, ensuring you have everything you need for labelling appliances after testing

Yes, 1000x Yes, 1000x Yes, 1000x  Yes, 500x

1000 x Circular Passed PAT Labels

Uniquely-designed passed PAT testing labels with circular design - ideal for smaller plugs or appliances where you can't easily fit other labels

Yes, 500x Yes, 1000x Yes, 1000x  Yes, 500x

500 x PAT Testing Cable Wrap Labels

These labels wrap around cables, and are great for labelling appliance power leads where you can't fix a suitable label

Yes, 500x Yes, 500x Yes, 500x  Yes, 500x

500 x Failed PAT Testing Labels

You won't need these very often, but if an appliance ever fails testing you should place one of these labels and take it out of use for repair or replacement

Yes, 500x Yes, 500x Yes, 500x  Yes, 500x

Visual Inspection Labels

You should check your appliances over for obvious signs of damage before testing. Look for frayed wires, loose connection and damaged plugs, then place one of these labels on if the appliance passes

No Yes Yes  Yes

SIMPLYPATS SoftwareSIMPLYPATS Software

Use SIMPLYPATS software alongside your PAT tester to download your results to PC and keep a database of all of your findings

No Yes Yes  Yes

PASSPTA27 Barcode ScannerBarcode Scanner

This Bluetooth/USB barcode scanner is great for speeding up your record-keeping by using your Megger PAT tester and barcode labels

No No Yes  Yes

Barcode Labels

Pair these up with your Bluetooth barcode scanner and quickly recall your previous records, or make new records, using your Apollo series PAT tester

No No Yes, 2000x  Yes, 1000x

Brother PrinterBrother Printer and Printer Cartridge

Create customised labels when out testing with this portable printer and cartridge pack!

 No  No No  Yes

 

Free PAT Reference Card

Enjoy peace of mind with a Free PAT Card included with every purchase. Keep track of essential safety checks effortlessly!

FREE Accessory Bundle
  • PASS Training Online Course with Exam, Pass & Fail Labels - PTPROMO7, typically £93.27
  • PASS The Complete Guide to EET (PAT) Testing, 5th Edition - PASS-PAT-HB, typically £24.99

Megger PAT410 Technical Specifications

Electrical Supply Range 230V ±10 @ 50/60Hz
Continuity Test (200mA)  
Continuity Test Voltage 9V AC ± 10% ± 0.1V
(supply: 230V 50Hz)
Continuity Resistance Accuracy ±5% ± 3 digits (0 to 0.49Ω)
±5% ± 5 digits (0.5 to 0.99Ω)
Continuity Resistance Resolution 10mΩ (1 to 19.99Ω)
Display Range 0 to 19.99Ω
Insulation Test (250V and 500V)  
Insulation Resistance Accuracy (230V) ±2% ±5 digits (0 to 19.99MΩ)
±5% ± 10 digits (20 to 99.99MΩ)
Insulation Resistance Resolution 0.01MΩ
Display Range 0 to 99.99MΩ
Substitute Leakage Test  
Test Voltage and Frequency 40V AC ±10% nominal mains frequency
Leakage Current Accuracy ±5% ± 5 digits
Leakage Current Resolution 0.01mA
Display Range 0 to 19.99mA
Differential Leakage Current  
Test Voltage Nominal mains 110/230V AC
Test Frequency Nominal mains 50/60Hz
Differential Leakage Current Accuracy ±5% ± 0.05mA (1.0mA to 9.99mA)
±5% ± 0.1mA (0.1mA to 0.99mA)
Resolution 0.01mA
Display/Measurement Range 0.10mA to 19.99mA
Test Duration User-selectable from 1 sec
10 sec to infinity
Touch Current Test  
Test Voltage and Frequency Nominal mains supply
Touch Current Accuracy ±5% ± 5 digits
Touch Current Resolution 0.01mA
Display 0 to 10mA
Operational Test  
Test Voltage and Frequency Nominal mains supply
VA Rating 230V 3700VA
110V 1800VA
VA Accuracy ±5% ± 10 digits (0 to 99VA)
±5% ± 50 digits (100VA to 999VA)
±5% ± 100 digits (1000VA to 3700VA)
Resolution 1VA (0 to 3700VA)
Display Range 0 to 3990VA
Extension Lead Test  
Tests Performed Bond, insulation and polarity
Polarity Test Voltage 12V
Polarity checks Lead ok
Live neutral S/C
Live neutral reversed
Live/neutral O/C
Portable RCD Test  
Test Voltage and Frequency Nominal mains supply
Test Current Accuracy -8% to -2% (1/2 x I)
+2 to +8% (1 x I, 5 x I)
Trip Time Accuracy ±1% ± 5 digits
Trip Time Resolution 0.1ms
Display Range 0 to 1999ms (1/2 x I)
0 to 300ms (1 x I)
0 to 40ms (5 x I)
Fuse Test  
Test Voltage 3.3V
Warning Audible beep if fuse is OK
Environmental  
Operating Temperature -10 to 50°C
Storage Temperature -20 to 60°C
Humidity 90% RH @ -10 to 30°C
75% RH @ +30 to 50°C
Maximum Altitude 2000m
Ingress Protection IP40
Other  
Weight 2.7kg
Dimensions 145 (H) x 255 (W) x 320mm (L)
Safety IEC 61010-1: CAT II 300V
EMC IEC 61326-1: 2006
IEC 61326-2-2: 2005
Accessories related to this product:
Megger PAT410 PAT Tester - Datasheet Datasheets

Reviews

Additional Information
SKU 1000-745
Manufacturer Part Code 1000-745
Model Ref PAT410
Country of Origin United Kingdom