FREE - PASS The Complete Guide to EET (PAT) Testing, 5th Edition
Buy a PAT testing kit and get an updated PAT Testing Guide worth £24.99. This 129 page indepth PAT testing book is a great addition to your kit. View PAT Guide
Our biggest and best Megger PAT410 kit, this bumper pack of PAT equipment includes everything in the other bundles, plus a Megger Printer and spare cartridge!
This kit is ideal for the professional PAT tester with a large number of appliances to test.
What's Inside?
- Megger PAT410 PAT Tester
- Printed Quick Start Guide
- Complete User Guide on CD
- Calibration Certificate
- Continuity/Earth Bond Lead + Probe
- Extension Lead Adapter (13A)
- Carrying Case
- Plug Adapter (IEC C6-C13)
- Screen Protector
We also include the following additional accessories:
- UNI-T UT07A Socket Tester
- CK Tools AV05050 5 Piece Insulated Screwdriver Set
- eLearning PAT Testing Course - Includes Exam and Certificate
- Microwave Leakage Detector
- 3 x IEC Adapter Set
- 2 x 110V Adapter Set
- 500 x Passed PAT Testing Labels
- 500 x Circular Passed PAT Testing Labels
- 500 x Cable Wrap PAT Labels
- 500 x Failed PAT Labels
- Visual Inspection Labels
- SIMPLYPATS Software
- Barcode Scanner
- Brother Printer (NEW for this kit)
- Printer Cartridge (NEW for this kit)
About the Megger PAT410 PAT Tester
No more logging down results, with the PAT410, you can store all your testing data on the instrument's memory, then download it to Excel or SIMPLYPATS included software!
The PAT410 is suitable for use with 230V appliances only. It can perform insulation testing at 250V and 500V, earth bond and continuity testing at 200mA, substitute, differential, and touch current tests, and more. It includes the ability to perform fast, automated testing procedures, or the user can configure their tests for full control over test times and pass limits.
This PAT tester also includes a full QWERTY keyboard for entering data, colour screen, a fuse check function, and more.
Megger PAT410 Downloadable PAT Tester Key Features
- Suitable for testing appliances with 230V supply
- Earth bond and continuity testing at 200mA with bond lead null
- Insulation testing at 250 and 500V
- Alternative leakage tests - substitute, differential, and touch current
- VA measurements
- Extension lead tests - earth bond, insulation, polarity, and portable RCD
- Lightweight design
- Auto testing procedures
- Manual testing procedures
- Fuse check function
- Colour display
- Configurable test times
- Selectable pass limits
- Lead storage pouch
- Fully downloadable memory - store up to 10000 records directly on the tester
Other Bundles
Find your perfect kit with this table!
Item | PAT Essentials Kit (Bundle 1) | PAT Business Kit (Bundle 2) | PAT Premium Kit (Bundle 3) | PAT Elite Printer Kit (Bundle 4) |
---|---|---|---|---|
UNI-T UT07A Socket Tester Need to check if your sockets are working right? Just plug this into a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
Yes | Yes | Yes | Yes |
CK Tools AV05050 Screwdriver Set This bundle pack includes a set of 5 fully insulated electrical screwdrivers which are suitable for live electrical work to 1000V |
Yes | Yes | Yes | Yes |
eLearning PAT Testing Course - Includes Exam and Certificate Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
Yes | Yes | Yes | Yes |
Microwave Leakage Detector It's common practice to check microwave radiation levels while you're PAT testing - use this portable, easy-to-use microwave leakage detector to do so |
Yes | Yes | Yes | Yes |
IEC Adapter Set A special bundle pack with three IEC adapters, allowing you to use your PAT tester with various types of IEC cables and power supplies |
Yes | Yes | Yes | Yes |
110V Adapter Set Use these two 110V connector leads to connect your PAT tester to 110V equipment commonly found on construction sites and similar applications |
Yes | Yes | Yes | Yes |
Passed PAT Testing Labels A PAT essential! We include two 500-label rolls in your purchase, ensuring you have everything you need for labelling appliances after testing |
Yes, 1000x | Yes, 1000x | Yes, 1000x | Yes, 500x |
1000 x Circular Passed PAT Labels Uniquely designed passed PAT testing labels with circular design - ideal for smaller plugs or appliances where you can't easily fit other labels |
Yes, 500x | Yes, 1000x | Yes, 1000x | Yes, 500x |
500 x PAT Testing Cable Wrap Labels These labels wrap around cables and are great for labelling appliance power leads where you can't fix a suitable label |
Yes, 500x | Yes, 500x | Yes, 500x | Yes, 500x |
500 x Failed PAT Testing Labels You won't need these very often, but if an appliance ever fails testing you should place one of these labels and take it out of use for repair or replacement |
Yes, 500x | Yes, 500x | Yes, 500x | Yes, 500x |
Visual Inspection Labels You should check your appliances for obvious signs of damage before testing. Look for frayed wires, loose connections, and damaged plugs, then place one of these labels on if the appliance passes |
No | Yes | Yes | Yes |
SIMPLYPATS Software Use SIMPLYPATS software alongside your PAT tester to download your results to a PC and keep a database of all of your findings |
No | Yes | Yes | Yes |
Barcode Scanner This Bluetooth/USB barcode scanner is great for speeding up your record-keeping by using your Megger PAT tester and barcode labels |
No | No | Yes | Yes |
Barcode Labels Pair these up with your Bluetooth barcode scanner and quickly recall your previous records, or make new records, using your Apollo series PAT tester |
No | No | Yes, 2000x | Yes, 1000x |
Brother Printer and Printer Cartridge Create customised labels when out testing with this portable printer and cartridge pack! |
No | No | No | Yes |
Megger PAT410 Technical Specifications
Electrical Supply Range | 230V ±10 @ 50/60Hz |
Continuity Test (200mA) | |
Continuity Test Voltage | 9V AC ± 10% ± 0.1V (supply: 230V 50Hz) |
Continuity Resistance Accuracy | ±5% ± 3 digits (0 to 0.49Ω) ±5% ± 5 digits (0.5 to 0.99Ω) |
Continuity Resistance Resolution | 10mΩ (1 to 19.99Ω) |
Display Range | 0 to 19.99Ω |
Insulation Test (250V and 500V) | |
Insulation Resistance Accuracy (230V) | ±2% ±5 digits (0 to 19.99MΩ) ±5% ± 10 digits (20 to 99.99MΩ) |
Insulation Resistance Resolution | 0.01MΩ |
Display Range | 0 to 99.99MΩ |
Substitute Leakage Test | |
Test Voltage and Frequency | 40V AC ±10% nominal mains frequency |
Leakage Current Accuracy | ±5% ± 5 digits |
Leakage Current Resolution | 0.01mA |
Display Range | 0 to 19.99mA |
Differential Leakage Current | |
Test Voltage | Nominal mains 110/230V AC |
Test Frequency | Nominal mains 50/60Hz |
Differential Leakage Current Accuracy | ±5% ± 0.05mA (1.0mA to 9.99mA) ±5% ± 0.1mA (0.1mA to 0.99mA) |
Resolution | 0.01mA |
Display/Measurement Range | 0.10mA to 19.99mA |
Test Duration | User-selectable from 1 sec 10 sec to infinity |
Touch Current Test | |
Test Voltage and Frequency | Nominal mains supply |
Touch Current Accuracy | ±5% ± 5 digits |
Touch Current Resolution | 0.01mA |
Display | 0 to 10mA |
Operational Test | |
Test Voltage and Frequency | Nominal mains supply |
VA Rating | 230V 3700VA 110V 1800VA |
VA Accuracy | ±5% ± 10 digits (0 to 99VA) ±5% ± 50 digits (100VA to 999VA) ±5% ± 100 digits (1000VA to 3700VA) |
Resolution | 1VA (0 to 3700VA) |
Display Range | 0 to 3990VA |
Extension Lead Test | |
Tests Performed | Bond, insulation and polarity |
Polarity Test Voltage | 12V |
Polarity checks | Lead ok Live neutral S/C Live neutral reversed Live/neutral O/C |
Portable RCD Test | |
Test Voltage and Frequency | Nominal mains supply |
Test Current Accuracy | -8% to -2% (1/2 x I) +2 to +8% (1 x I, 5 x I) |
Trip Time Accuracy | ±1% ± 5 digits |
Trip Time Resolution | 0.1ms |
Display Range | 0 to 1999ms (1/2 x I) 0 to 300ms (1 x I) 0 to 40ms (5 x I) |
Fuse Test | |
Test Voltage | 3.3V |
Warning | Audible beep if fuse is OK |
Environmental | |
Operating Temperature | -10 to 50°C |
Storage Temperature | -20 to 60°C |
Humidity | 90% RH @ -10 to 30°C 75% RH @ +30 to 50°C |
Maximum Altitude | 2000m |
Ingress Protection | IP40 |
Other | |
Weight | 2.7kg |
Dimensions | 145 (H) x 255 (W) x 320mm (L) |
Safety | IEC 61010-1: CAT II 300V |
EMC | IEC 61326-1: 2006 IEC 61326-2-2: 2005 |
Reviews
SKU | PAT410BUNDLE4 |
---|---|
Manufacturer Part Code | PAT410BUNDLE4 |