Speed up your PAT testing with the Fluke 6200-2, an easy-to-use, fast portable appliance tester that's suitable for use with all appliances.
The Fluke 6200-2 PAT tester is designed to make performing PAT tests as simple as possible.
All you need to do is connect your appliance to the 6200-2 by the built-in 3-pin mains socket or IEC port, then press a dedicated button to activate each test. This one-touch testing ability makes it significantly easier to actually perform tests, and helps you to get more done without complicated setup.
The 6200-2 performs all required tests as defined in the IET Code of Practice, including:
You can use the 6200-2 to test class I and class II appliances, IEC leads, extension leads, IT equipment and - via the use of optional 110V and 415V adapters - use the tester to perform electrical safety checks on 110V equipment found on construction sites etc or 415V 3-phase industrial equipment.
The Fluke 6200-2 is designed with portability and ease of use in mind, with a strong, lightweight enclosure to ensure you can easily port it from test to test and easily set it up with different appliances.
This PAT tester has a number of benefits, including:
The Fluke 6200-2 is classed as a 'manual' PAT tester - although this unit does have built-in memory storage, stored results can only be viewed on the tester itself and cannot be downloaded to PC. If you require downloadable memory storage, consider upgrading to the Fluke 6500-2 PAT tester.
If you're interested in Fluke's 6200-2 tester, why not also consider upgrading to one of our PAT testing kits for this instrument?
Our PAT kits include absolutely everything you'll need for PAT testing, including the tester, all standard accessories, labels, an eLearning PAT Testing Course, a PASS handbook with guidance on portable appliance testing and much more.
The table below outlines the difference between each bundle, or you can view each by clicking the following links:
Item Description | Fluke 6200-2 PAT Tester Essentials Kit (Bundle 1) | Fluke 6200-2 PAT Tester Professional Kit (Bundle 2) |
---|---|---|
Socket Tester Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
√ | √ |
eLearning PAT Testing Course - Includes Exam and Certificate Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
√ |
√ |
The PASS Handbook of Portable Appliance Testing Everything you need to know about PAT testing is outlined in this comprehensive book. Inside, you'll find useful information, colour-coded sections, photographic examples and much more to help you PAT test on a daily basis. |
√ | √ |
PASS PAT Testing Logbook Keep a record of all of your testing with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference. |
√ | √ |
Microwave Leakage Detector When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector you'll be able to do this testing with ease. |
√ | √ |
PASSPTA21 - IEC (C13 Female) You'll need this adaptor to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector. |
√ | √ |
PASSPTA29 - IEC Plug (C14) This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment. |
√ | √ |
PASSPTA28 - IEC Plug (C14) You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adaptor, you can connect them up to your PAT tester. |
√ | √ |
CK Tools AV05050 5 Piece Insulated Screwdriver Kit A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications. |
√ | √ |
WM1 - 500 x Passed PAT Testing Labels You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done. |
√ | √ |
WM6500 - 500 x Circular Passed PAT Testing Labels These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due. |
√ | √ |
WM12 250 - 250 x Cable Wrap Labels These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date. |
√ | √ |
WM7 250 - 250 x Failed PAT Testing Labels You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement |
√ | √ |
SimplyPats Manual PAT Testing Software Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand. |
- | √ |
Enjoy peace of mind with a Free PAT Card included with every purchase. Keep track of essential safety checks effortlessly!
Test Specifications | The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75 % RH. | |
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. | ||
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2. | ||
Power-on Test | The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. | |
Display Range | 90 V to 264 V | |
Accuracy at 50 Hz | ± (2% + 3 counts) | |
Resolution | 1 V | |
Input Impedance | > 1 MΩ // 2.2 nF | |
Maximum Input Mains Voltage | 264 V | |
Earth Bond Test (Rpe) | Display Range | 0 to 19.99 Ω |
Accuracy (After Bond Test Zeroing) | ± (2.5% + 4 counts) | |
Resolution | 0.01 Ω | |
Test Current | 200 mA AC -0% +40% into 1.99 Ω 25 A AC ± 20% into 25 mΩ at 230 V |
|
Open Circuit Voltage | > 4 V AC, < 24 V AC | |
Bond Test Zeroing | can subtract up to 1.99 Ω | |
Insulation Test (Riso) | Display Range | 0 to 299 MΩ |
Accuracy | ± (5% + 2 counts) from 0.1 to 300 MΩ | |
Resolution | 0.01 MΩ (0 to 19.99 MΩ) 0.1 MΩ (20 to 199.9 MΩ) 1 MΩ (200 to 299 MΩ) |
|
Test Voltage | 500 V DC -0% + 10% at 500 kΩ load | |
Test Current | > 1 mA at 500 kΩ load, < 15 mA at 0 Ω | |
Auto Discharge Time | < 0.5 s for 1 μF | |
Max. Capacitive Load | Operational up to 1 μF | |
Touch Current Test | Display Range | 0 to 1.99 mA AC |
Accuracy | ± (4% + 2 counts) | |
Resolution | 0.01 mA | |
Internal Resistance (via Probe) | 2 kΩ | |
Measuring Method | Probe* | |
Substitute Leakage Current Test | Display Range | 0 to 19.99 mA AC |
Accuracy | ± (2.5% + 3 counts) | |
Resolution | 0.01 mA | |
Test Voltage | 100 V AC ± 20% | |
Load/Leakage Test: Load Current | Display Range | 0 A to 13 A |
Accuracy | ± (4% + 2 counts) | |
Resolution | 0.1 A* | |
Load/Leakage Test: Load Power | Display Range 230 V Mains | 0.0 VA to 3.2 kVA |
Accuracy | ± (5 % + 3 counts) | |
Resolution | 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)* | |
Load/Leakage Test: Leakage Current | Display Range | 0 to 19.99 mA |
Accuracy | ± (4% + 4 counts) | |
Resolution | 0.01 mA* | |
PELV Test | Accuracy at 50 Hz | ± (2% + 3 counts) |
Overload Protection | 300 V rms | |
Warning Threshold | 25 V rms | |
*The appliance under test is energized at mains potential. |
Environmental Specifications |
|
Operating Temperature | 0 to 40 °C |
Relative Humidity | Non condensing < 10 °C 95% from 10 to 30 °C 75% from 30 to 40 °C |
Safety Specifications |
|
Safety Rating | Complies with EN61010-1 3rd edition |
CAT II, 300 V, pol 2 |
Mechanical & General Specifications |
||
Size | 200 mm (L) x 275 mm (W) x 114 mm (H) | |
Weight | 3.13 kg | |
Power Supply | 230 V +10 % -15 %, 50 Hz ±2 | |
Power Consumption (Tester) | 13 W typical (idle) 60 W max. during 25A Bond test |
|
Storage | Temperature | -10 to 60 °C |
Corrosion | 70 °C @ 95 % RH for 5 days max. | |
Operating Altitude | 0 up to 2000 m | |
Sealing | IP-40 (enclosure), IP-20 (connectors) | |
EMC | Complies with EN61326-1, portable | |
EMI Immunity | 3 V/m |