This kit is ideal for solar photovoltaic (PV) installation technicians and maintenance professionals working in high-voltage DC environments. It includes:
- Fluke 393FC Solar Clamp Meter with Accessories
- Fluke Pomona PVLEAD1 MC4 Solar Test Leads
- Fluke Pomona PVLEAD3 MC4 Solar Test Leads
- Fluke IRR1-SOL Solar Irradiance Meter with Accessories
Fluke 393FC True-RMS Solar Clamp Meter Overview
The Fluke 393FC True-RMS Solar Clamp Meter is an IP54-certified, CAT III 1500V-safety-rated AC/DC clamp designed to measure 1500V DC systems. Its thin jaws enable access to cables in crowded combiner boxes. The following parameters can be measured via the Fluke 393FC’s Clamp:
- DC voltage: up to 1500V
- AC voltage: up to 1000V
- AC/DC: up to 999.9A
In addition to this, the Fluke 393FC True-RMS Solar Clamp can measure DC power (kVA) and features audio polarity and visual continuity indicators. Furthermore, an iFlex Flexible current probe extends the Fluke 393FC True-RMS Solar Clamp’s AC range to 2500A and facilitates access to tight spaces.
Fluke Connect technology allows you to log results wirelessly to the Fluke Connect App. Once saved to the Fluke Connect App, data can be analysed, shared, or used to create reports.
The Fluke 393FC True-RMS Solar Clamp is ideal for checking solar arrays, wind power equipment, electric railways, data centres, and battery banks.
Please click here for more information about the Fluke 393FC True-RMS Solar Clamp.
Fluke Pomona PVLEAD1 MC4 Solar Test Leads Overview
Ideal for regular testing, measuring, and troubleshooting of solar PV panels, the Fluke Pomona PVLEAD1 MC4 Solar Test Leads allow you to connect test tools that accept 4mm banana plugs (such as the Fluke 393FC Solar Clamp Meter) to PV panels, modules, and systems. Via this connection, you can measure voltage and current safely. The Fluke Pomona PVLEAD1 MC4 Solar Test Leads are CAT III 1000V/ CAT IV 600V safety rated and comply with 20A ratings according to IEC/EN 61010-031.
Fluke Pomona PVLEAD3 MC4 Solar Test Leads Overview
Specifically designed for use with solar clamp meters that accept 4mm banana plugs, such as the Fluke 393FC Solar Clamp Meter, the Fluke Pomona PVLEAD3 MC4 Solar Test Leads facilitate a connection between the solar panel and inverter enabling troubleshooting and maintenance inspections. They ensure that you can take safe DC power measurements on PV modules and systems without interrupting power generation. The Fluke Pomona PVLEAD3 MC4 Solar Test Leads are CAT III 1000V/ CAT IV 600V safety rated and comply with 20A ratings by IEC/EN 61010-031.
Fluke IRR1-SOL Solar Irradiance Meter Overview
Ideal for solar installers and technicians working on roof-mounted systems or large-field installations, the Fluke IRR1-SOL Solar Irradiance Meter provides a simple solution to installing, testing, and maintaining solar panels by IEC 62446-1 requirements. This rugged, compact meter with a high-contrast display can measure solar arrays' irradiance, temperature, inclination, and direction. To this end, the Fluke IRR1-SOL Solar Irradiance Meter includes a high-precision mono-crystalline solar sensor, two temperature measurement options, an integrated compass, and an inclination sensor.
Follow this link to read more about the Fluke IRR1-SOL Solar Irradiance Meter.
What’s Included?
- Fluke 393FC True-RMS Solar Clamp Meter
- Test Leads (CAT III 1500V, right-angle plugs, safety caps)
- iFlex 18-inch Flexible Current Probe
- TPAK Magnetic Hanging Strap
- Premium Carry Case
- Fluke IRR1-SOL Solar Irradiance Meter
- Fluke FLK80PR-IRR External Temperature Probe with Suction Cup
- Fluke C250 Carrying Case with Shoulder Strap
- Pomona PVLEAD1 MC4 to 4mm Test Lead Set
- Pomona PVLEAD3 MC4 Solar Clamp Test Lead Set
Fluke 393 FC CAT III 1500V True-RMS Clamp Meter with iFlex Technical Specifications
General | |
Maximum voltage between any Terminal and Earth Ground | |
AC | 1000 V |
DC | 1500 V |
Batteries | 2 AA IEC LR6 alkaline |
Display | Dual display with backlight |
Automatic Power Off | 20 minutes |
Electrical | |
Accuracy | Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 75 %. Accuracy specifications take the form of ±([% of Reading] + [Number of Least Significant Digits]). |
Temperature Coefficients | Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C |
AC Current: Jaw | |
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2 % + 5 digits (10 Hz to 100 Hz) |
2.5 % + 5 digits (100 Hz to 500 Hz) | |
Crest Factor (50/60 Hz) | 2.5 @600.0 A |
3.0 @500.0 A | |
1.42 @999.9 A | |
Add 2 % for C.F. >2 | |
AC Current: Flexible Current Probe | |
Range | 999.9 A |
2500 A | |
Resolution | 0.1 A (≤999.9 A) |
1 A (≤2500 A) | |
Accuracy | 3 % RD + 5 digits (10 Hz to 500 Hz) |
Crest Factor (50/60Hz) | 2.5 @1400 A |
3.0 @1100 A | |
1.42@2500 A | |
Add 2 % for C.F. >2 | |
DC Current | |
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2 % RD + 5 digits[1] |
Note | [1] When using the ZERO (B) function to compensate for offsets. |
AC Voltage | |
Range | 600.0 V |
1000 V | |
Resolution | 0.1 V (≤600.0 V) |
1 V (≤1000 V) | |
Accuracy | 1 % RD + 5 digits (20 Hz to 500 Hz) |
DC Voltage | |
Range | 600.0 V |
1500 V | |
Resolution | 0.1 V (≤600.0 V) |
1 V (≤1500 V) | |
Accuracy | 1 % RD + 5 digits |
mV DC | |
Range | 500.0 mV |
Resolution | 0.1 mV |
Accuracy | 1 % RD + 5 digits |
Amps Frequency: Jaw | |
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % RD + 5 digits |
Trigger Level | 5 Hz to 10 Hz, ≥10 A |
10 Hz to 100 Hz, ≥5 A | |
100 Hz to 500 Hz, ≥10 A | |
Amps Frequency: Flexible Current Probe | |
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % RD + 5 digits |
Trigger Level | 5 Hz to 20 Hz, ≥25 A |
20 Hz to 100 Hz, ≥20 A | |
100 Hz to 500 Hz, ≥25 A | |
Voltage Frequency | |
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % RD + 5 digits |
Trigger Level | 5 Hz to 20 Hz, ≥5 V |
20 Hz to 100 Hz, ≥5 V | |
100 Hz to 500 Hz, ≥10 V | |
DC Power | |
Range | 600.0 kVA (600.0 V dc range) |
1500 kVA (1500 V dc range) | |
Resolution | 0.1 kVA |
1 kVA | |
Accuracy | 2 % RD + 2.0 kVA |
2 % RD + 20 kVA | |
Resistance | |
Range | 600.0 Ω |
6000 Ω | |
60.00 kΩ | |
Resolution | 0.1 Ω (≤600.0 Ω) |
1 Ω (≤6000 Ω) | |
0.01 kΩ (≤60.00 kΩ) | |
Accuracy | 1 % RD + 5 digits |
Capacitance | |
Range | 100.0 μF |
1000 μF | |
Resolution | 0.1 μF (≤100.0 μF) |
1 μF (≤1000 μF) | |
Accuracy | 1 % RD + 5 digits |
Inrush Trigger Level | 5 A |
Mechanical | |
Size (L x W x H) | 281 mm x 84 mm x 49 mm |
Weight (with batteries) | 520 g |
Jaw Opening | 34 mm |
Flexible Current Probe Diameter | 7.5 mm |
Flexible Current Probe Cable Length (head to electronics connector) | 1.8 m |
Environmental | |
Operating Temperature | -10 °C to 50 °C |
Storage Temperature | -40 °C to 60 °C |
Operating Humidity | Non condensing (<10°C) |
≤90 % RH (at 10 °C to 30 °C) | |
≤75 % RH (at 30 °C to 40 °C) | |
≤45 % RH (at 40 °C to 50 °C) | |
Operating Altitude | 2000 m |
Storage Altitude | 12 000 m |
Ingress Protection (IP) Rating | IEC 60529: IP54 non-operating |
Electromagnetic Compatibility (EMC) | |
International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A |
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | |
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. | |
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. | |
Korea (KCC) | Class A equipment (Industrial Broadcast & Communications Equipment) |
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Safety | |
General | IEC 61010-1, Pollution Degree 2 |
Measurement | IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V |
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V | |
Wireless Radio | |
Radiofrequency certification | FCC ID: T68-FBLE, IC: 6627A-FBLE |
Wireless Radio Frequency Range | 2400 MHz to 2483.5 MHz |
Output Power | <100 mW |
SIMPLIFIED EU DECLARATION OF CONFORMITY | Hereby, Fluke declares that the radio equipment contained in this product complies with Directive 2014/53/EU. |
Fluke IRR1-SOL Solar Irradiance Meter Technical Specifications
Irradiance | |
Measuring Range | 0 to 1400 W/m² |
Resolution | 1 W/m² |
Measuring Accuracy | ± (5 % + 5 Digit) |
Temperature Measurement | |
Measuring range (°C) | -22 °F to 212 °F (-30 °C to 100 °C) |
Resolution | 0.2 °F (0.1 °C) / 1 °F @>100 °F |
Measuring Accuracy | ±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C), ±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C) and 167 °F to 212 °F (75 °C to 100 °C) |
Note | Temperature measurement response time: ~30 sec |
Inclination Angle | |
Measuring Range | -90° to +90° |
Resolution | 0.1° |
Measuring Accuracy | ± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85° ±3.5° @ -90° to -85° and +85° to +90° |
Compass | |
Measuring Range | 0° to 360° |
Resolution | 1° |
Measuring Accuracy | ± 7° |
Note | a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown “---”. |
b) Result is referred to as magnetic north. | |
Temperature | |
Operating Temperature IRR1-SOL | -20 °C to 50 °C (humidity <80 %), non-condensing |
Operating Temperature 80PR-IRR | -30 °C to 100 °C |
Storage Temperature | -30 °C to 60 °C (humidity <80 %) |
Altitude | 0 m to max. 2000 m |
Electromagnetic Compatibility (EMC) | |
International | IEC 61326-1: Portable Electromagnetic Environment CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively coupled radiofrequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Protection | |
IP Protection | IP40 |
Power Supply & Battery Life | |
Batteries | 4 AA Alkaline Batteries |
Battery Life (typical) | 50 hours (> 9000 readings) |
Auto Power Off | 30 minutes |
Dimensions | |
L x W x H | 5.90 x 3.14 x 1.37 in (150 x 80 x 35 mm) |
Weight | 0.5 lb (231 g) |
Reviews
SKU | 5337401 |
---|---|
Manufacturer Part Code | 5337401 |
Country of Origin | China |