The TSI Airflow™ TA410 Hot Wire Anemometer is a precise digital air velocity meter. This thermal anemometer is ideal for troubleshooting HVAC systems and conducting commissioning work. It can also be used for plant maintenance, critical environment certification and duct traverses.
The TSI Airflow™ TA410 Hot Wire Anemometer measures air velocity and temperature using a straight, telescopic probe. It has the following measurement ranges:
- Velocity: 0-20 m/s
- Temperature: -18ºC to 93ºC (0ºF to 200ºF)
Its integrated 101.6 cm (40 in) telescopic probe enables measurement of difficult-to-access places.
Measurements are visible on the TSI Airflow™ TA410 Hot Wire Anemometer's large, easy-to-read display. Readings can be frozen on the display using the Hold button.
The TSI Airflow™ TA410 Hot Wire Anemometer is an accurate, reliable and ergonomic digital air velocity meter.
TSI Airflow™ TA410 Hot Wire Anemometer Key Features
- Precise digital air velocity meter
- Troubleshoot HVAC systems
- Conduct commissioning work
- Suitable for plant maintenance
- Can be used for critical environment certification
- Conduct duct traverses
- Measures air velocity and temperature
- 101.6 cm (40 in) telescoping probe for measuring difficult-to-access places
- Large, easy-to-read display
- An accurate, reliable and ergonomic digital air velocity meter
What’s Included?
- TSI Airflow™ TA410 Hot Wire Anemometer
- Hard Carrying Case
- Four Alkaline Batteries
- Operation and Service Manuals
- Calibration Certificate
TSI Airflow™ TA410 Hot Wire Anemometer Technical Specifications
Velocity | |
Range | 0 to 20 m/s (0 to 4,000 ft/min) |
Accuracy | ±5% of reading or ±0.025 m/s (±5 ft/min), whichever is greater |
Resolution | 0.01 m/s (1 ft/min) |
Temperature | |
Range | -10 to 60°C (14 to 140°F) |
Accuracy3 | ±0.3°C (±0.5°F) |
Resolution | 0.1°C (0.1°F) |
Instrument Temperature Range | |
Operating (Electronics) | 5 to 45°C (40 to 113°F) |
Operating (Probe) | -18 to 93°C (0 to 200°F) |
Storage | -20 to 60°C (-4 to 140°F) |
External Meter Dimensions | 8.4 cm x 17.8 cm x 4.4 cm (3.3 in. x 7.0 in. x 1.8 in.) |
Meter Weight with Batteries | 0.27 kg (0.6 lbs.) |
Meter Probe Dimensions | |
Probe Length | 101.6 cm (40 in.) |
Probe Diameter of Tip | 7.0 mm (0.28 in.) |
Probe Diameter of Base | 13.0 mm (0.51 in.) |
Articulating Probe Dimensions | |
Articulating Section Length | 19.7 cm (7.8 in.) |
Diameter of Articulating Knuckle | 9.5 mm (0.38 in.) |
Power Requirements | Four AA-size batteries or AC adapter |
Note | 3 - Accuracy with instrument case at 25°C (77°F), add uncertainty of 0.03°C/°C (0.05°F/°F) for change in instrument temperature |
Reviews
SKU | TA410 |
---|---|
Manufacturer Part Code | TA410 |