Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
TSI IAQ-Calc Meters assess and track indoor air quality (IAQ). The 7515 offers an affordable solution for carbon dioxide (CO₂) monitoring. Models 7525 and 7545 measure and log multiple parameters simultaneously. The 7525 captures CO₂, temperature, and humidity while also calculating dew point, wet bulb temperature, and percentage outside air. The 7545 extends these capabilities by including carbon monoxide (CO) detection.
Feature | 7515 | 7525 | 7545 |
---|---|---|---|
CO₂ | + | + | + |
CO | + | ||
Temperature | + | + | |
Humidity | + | + | |
Percentage outside air | + | + | |
Dew point | + | + | |
Wet bulb temperature | + | + | |
Data logging/downloading | + | + | |
Statistics | + | + | + |
Review data | + | + | |
Certificate of Calibration | + | + | + |
7515 | 7525 | 7545 | |
---|---|---|---|
CO₂ Sensor Type | Dual-wavelength NDIR (non-dispersive infrared) | ||
CO₂ Range | 0 to 5,000 ppm | ||
CO₂ Accuracy* | ±3.0% of reading or ±50 ppm, whichever is greater | ||
CO₂ Resolution | 1 ppm | ||
CO₂ Response Time | 20 seconds | ||
Temperature Sensor Type | N/A | Thermistor | |
Temperature Range | 0 to 60°C (32 to 140°F) | ||
Temperature Accuracy | ±0.5°C (±1.0°F) | ||
Temperature Resolution | 0.1°C (0.1°F) | ||
Temperature Response Time | 30 seconds (90% final value, air velocity 2 m/s [400 ft/min]) | ||
Relative Humidity Sensor Type | N/A | Thin-film capacitive | Thin-film capacitive |
RH Range | 5% to 95% RH | ||
RH Accuracy** | ±3.0% RH | ||
RH Resolution | 0.1% RH | ||
RH Response Time | 20 seconds (63% final value) | ||
Percentage Outside Air Range | 0 to 100% | ||
Percentage Outside Air Resolution | 0.1% | ||
CO Sensor Type | N/A | Electro-chemical | |
CO Range | 0 to 500 ppm | ||
CO Accuracy | ±3.0% of reading or ±3 ppm, whichever is greater | ||
CO Resolution | 0.1 ppm | ||
CO Response Time | <60 seconds to 90% step change | ||
Operating Temperature | 5 to 45°C (40 to 113°F) | ||
Storage Temperature | -20 to 60°C (-4 to 140°F) | ||
Logging Capability Ranges | N/A | Logs up to 30,300 data points with key (3) measured parameters enabled | Logs up to 26,900 data points with key (4) measured parameters enabled |
Time Constant | 1 sec, 5 sec, 10 sec, 20 sec, 30 sec (user selectable) | ||
Log Intervals | User-selectable: 1 second to 1 hour | ||
Meter Dimensions | 8.4 cm x 17.8 cm x 4.4 cm (3.3 in. x 7.0 in. x 1.8 in.) | ||
Probe Dimensions | 7.0 cm length x 1.9 cm diameter (2.75 in. x 0.75 in.) | 17.8 cm length x 1.9 cm diameter (7.0 in. x 0.75 in.) | |
Weight (with batteries) | 0.27 kg (0.6 lbs) | ||
Power Requirements | Four AA batteries | Four AA batteries or AC adapter |