The TSI 9535 VelociCalc Air Velocity Meter measures and completes data logging of ventilation parameters. This meter simultaneously measures air velocity and temperature while calculating flow rate using a straight, telescopic probe equipped with multiple sensors. The VelociCalc 9535 simplifies complex tasks that would require numerous instruments.
9515 |
9535 9535-A |
9545 9545-A |
|
Velocity range 0 to 4000 ft/min (0 to 20.00 m/s) |
✔ | ✖ | ✖ |
Velocity ranges from 0 to 6000 ft/min (0 to 30.00 m/s) |
✖ | ✔ | ✔ |
Temperature | ✔ | ✔ | ✔ |
Flow | ✖ | ✔ | ✔ |
Humidity, wet bulb, dew point | ✖ | ✖ | ✔ |
Probe | Straight | Straight or -A articulated |
Straight or -A articulated |
Variable time constant | ✖ | ✔ | ✔ |
Manual data logging | ✖ | ✔ | ✔ |
Autosave data logging | ✖ | ✖ | ✔ |
Statistics | ✖ | ✔ | ✔ |
Review data | ✖ | ✔ | ✔ |
LogDat2™ downloading software |
✖ | ✔ | ✔ |
Certificate of Calibration | ✔ | ✔ | ✔ |
Velocity | |
---|---|
Range | 0 to 6,000 ft/min (0 to 30 m/s) |
Accuracy1 & 2 | ±3% of reading or ±3 ft/min (±0.015 m/s), whichever is greater |
Resolution | 1 ft/min (0.01 m/s) |
Duct Size | |
Dimensions | 1 to 250 inches in increments of 0.1 in. (1 to 635 cm in increments of 0.1 cm) |
Volumetric Flow Rate | |
Range | Actual range is a function of velocity and duct size |
Temperature | |
Range | 0 to 200 °F (-18 to 93°C) |
Accuracy3 | ±0.5°F (±0.3°C) |
Resolution | 0.1°F (0.1°C) |
Instrument Temperature Range | |
Operating (Electronics) | 40 to 113°F (5 to 45°C) |
Operating (Probe) | 0 to 200°F (-18 to 93°C) |
Storage | -4 to 140°F (-20 to 60°C) |
Data Storage Capabilities | |
Range | 12,700+ samples and 100 test IDs |
Logging Interval | 1 second to 1 hour |
Time Constant | User selectable |
External Meter Dimensions | 3.3 in. x 7.0 in. x 1.8 in. (8.4 cm x 17.8 cm x 4.4 cm) |
Meter Weight with Batteries | 0.6 lbs. (0.27 kg) |
Meter Probe Dimensions | |
Probe Length | 40 in. (101.6 cm) |
Probe Diameter of Tip | 0.28 in. (7.0 mm) |
Probe Diameter of Base | 0.51 in. (13.0 mm) |
Articulating Probe Dimensions | |
Articulating Section Length | 7.8 in. (19.7 cm) |
Diameter of Articulating Knuckle | 0.38 in. (9.5 mm) |
Power Requirements | Four AA-size batteries or AC adapter |
Note | 1 Temperature compensated over an air temperature range of 40 to 150°F (5 to 65°C). 2 The accuracy statement begins at 30 ft/min through 4000 ft/min. (0.15 m/s through 20 m/s) for Model 9515, and 30 ft/min through 6,000 ft/min (0.15 m/s through 30 m/s) for Models 9535 and 9545. 3 Accuracy with instrument case at 77°F (25°C), add uncertainty of 0.05°F/°F (0.03°C/°C) for change in instrument temperature. |