Designed for measuring cable attenuation in multimode and single-mode cabling, the Trend Networks R240-QIP FiberMASTER is a compact power meter also capable of troubleshooting LAN and telecom networks. Furthermore, when used with a Trend Networks FiberMASTER light source the Trend Networks R240-QIP FiberMASTER can directly measure the cable attenuation and output power of optical equipment. Additionally, when the power meter and light source are used in combination with a fibre inspection probe, they can capture images of connectors at each end of the cabling. This is particularly useful as over 90% of all fibre optic cable and network issues are caused by damaged or dirty fibre connectors.
Trend Networks R240-QIP FiberMASTER Mini Quad OTDR Fibreoptic Cable Tester Key Features
- Compact power meter
- Measure cable attenuation in multimode and single-mode cabling
- Troubleshoot LAN and telecom networks
- Use with a FiberMASTER light source to measure the cable attenuation and output power of optical equipment
- Use with light source and fibre inspection probe to capture images of connectors
- ORL measurement: up to -60 dB
- 82 dB power meter dynamic range
- Compatible with the auto-centring/Pass/Fail video probe
- Auto test up to three wavelengths
- Auto wavelength switching
- Universal power meter and light source adapters
- Store up to 40 000 tests
- Bright colour display
- Rechargeable lithium battery
- USB interface
- CertSoft free reporting software
- Onboard help
- Pass/Fail to IEC61300-3-35 standard
- 150x and 300x zoom level
- Automatic image positioning
- Stores images in FiberMASTER testers
- Attach images to OTDR/ Power Meter test reports
- Multiple connector adapters available
- One-hand operation
What’s Included?
- Trend Networks R240-QIP FiberMASTER Mini Quad OTDR Fibreoptic Cable Tester
- MM 2m Cable LC-SC
- MM 2m Cable SC-SC
- SM 2m Cable LC-SC
- SM 2m Cable SC-SC
- Power Meter Connectors (LC, SC, FC, ST, 1.25mm UNIV, 2.5mm UNIV)
- 25mm Cleaning Pen
- 5mm Cleaning Pen
- Power Adapter
- USB Cable
- Stylus
- Quick Reference Guide
- Hard Carry Case
OTDR | |
---|---|
Wavelength | 850, 1300, 1310, 1550, (PON) 1625 nm |
Dynamic Range (dB) | 29/30 MM, 37/38 SM, 36 PON |
Dead Zones | 1m Event, 5m Attenuation |
Resolution | 6 cm - 16 m / 2 in - 52 ft |
Distance Uncertainty | ±(0.75m + 0.005% x distance + sampling res.) Verified by GHMT laboratories |
Sampling Points | Up to 128,000 |
Storage | Approx 40,000 results |
Size/Weight | 170 mm (6.7 in) 108 mm (4.2 in) x 51 mm (2.0 in) 730 g (1.6 lbs) |
Connector | SC included. FC, ST optional |
VFL | 1 mW (5 km), 2.5 mm Universal |
Power Meter | |
---|---|
Wavelength | 850, 1300, 1310, 1490, 1550, 1625 nm |
Measurement Range | +5 to -77 dBm |
Uncertainty | ± 0.18 dB reference conditions ± 0.25 dB from 0 to -65 dBm ± 0.35 dB from 0 to +5 dBm ± 0.35 dB -65 to -77 dBm |
Resolution | 0.01 dB |
Connectors | LC/SC/FC/ST/2.5mm/1.25mm included |