The 194 is a uniquely-designed, true-RMS digital multimeter with triple line display, allowing more information to be shown simultaneously than other DMMs.
This multiemter can test DC and AC voltage to 1000V, DC and AC current to 10A, resistance to 50MΩ, frequency to 5MHz, capacitance to 20mF, inductance to 300mH, temperature (using a K-type thermocouple) to 2462°F (1350°C) and can also test continuity and diode.
Additionally, this multimeter also has conductance, duty cycle, pulse width and time stamp logging functionality. A built-in data hold function can be used to store values taken over a time period or the MIN/MAX function can calculate the minimum or maximum value taken over a time period. Dedicated relative and comparison modes are also included.
DC Volts | Maximum Input: 1000V
Maximum Resolution: 0.0001mV Accuracy: +/-0.05% |
AC Volts | Maximum Input: 1000V
Maximum Resolution: 100μμV Accuracy: +/-0.4% |
DC Amps | Maximum Input: 10A
Maximum Resolution: 0.01μA Accuracy: +/-0.15% |
AC Amps | Maximum Input: 10A
Maximum Resolution: 0.01μA Accuracy: +/-0.75% |
Resistance (Ohms) | Maximum Input: 50MΩ
Maximum Resolution: 1mΩ Accuracy: +/-0.05% |
Frequency | Maximum Input: 5MHz
Maximum Resolution: 0.001Hz Accuracy: +/-0.05% |
Capacitance | Maximum Input: 20mF
Maximum Resolution: 0.01nF Accuracy: +/-2% |
Inductance | Maximum Input: 300mH
Maximum Resolution: 0.01mH Accuracy: +/-5% |
Temperature
(K-Type Thermocouple) |
Maximum Input: -54°F to 2462°F (-50°C to 1350°C)
Maximum Resolution: 0.1°F / °C Accuracy: +/-2% |
Continuity | Audible at less than 10Ω |
Diode | 3V at 1mA maximum output |
Duty Cycle | Maximum Input: 99.9%
Maximum Resolution: 0.1% |
True RMS Responding | Yes |
Conductance | Yes |
Pulse Width | Yes |
Data Hold | Yes (Two hold system) |
Min/Max Record | Yes |
Time Stamp Logging | Yes |
Relative Mode | Yes |
Compare Mode | Yes |
RS-232 Output | Yes, Optically Isolated |
Process Loop Output | No |
Sleep Mode / Auto Off | Yes |
Protective Boot | Yes (standard) |
Display Type | 50,000 count backlit LCD with dual sub displays and analog bargraph |
Range Selection | Auto / Manual |
Operating Temperature | 32°F to 113°F (0°C to 40°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Humidity | 80% non-condensing |
Size | 8.3” x 3.7” x 1.9” (210mm x 95mm x 47mm) without boot
8.7” x 4.3” x 2.6 (220mm x 110mm x 65mm) with boot |
Weight | 1.3lbs (570g) without boot
1.9lbs (850g) with boot |
Battery Type | 9V Alkaline (NEDA 1604) |
Battery Life | 50hrs Typical |
OverInput Category | CAT III 600V |
Agency Approval | cULus 61010-1, IEC 61010-1 |
Warranty | Limited Lifetime |