All Time Electronics Products

Time Electronics 1090 Portable Process Calibrator

SKU
1090
Rating:
0%
(0)
Reward Points
:
1519
£1,822.80 £1,519.00
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Time Electronics Temperature And Process Calibrator

This high specification process calibrator is lightweight, portable, battery or mains powered calibration unit and can be used to source and measure thermocouples, PT100s, μV, mV and mA.

When used with thermocouples, the 1090 can be used to measure/simulate temperature (in both Celsius and Fahrenheit) plus mV characteristics of type J, K, T, R, S, B, N and E type thermocoples. It also includes the ability to carry out PT100 measurement and simulations (based on 0.3850 alpha probe standard) between a range of -200 to 700°C.

The final measurement/simulation mode on this device enables it to measure 0 to ±30mV and 0 to ±60mA and source from 0 to ±80mV and 0 to ±80mA. 

This calibration device also comes with cold junction compensation, meaning it can be operated with ot without internal cold junction compensation. Other additional features include a 24V process loop drive mode, inching (incrementing/decrementing) and built-in memory.

Time Electronics 1090 Portable Process Calibrator Key Features

  • Measures and simulates 8 thermocouple types - J, K, T, R, S, B, N and E
  • Measures and simulates PT100-RTD
  • Measures and sources μV, mV and mA
  • Switch between Celsius and Fahrenheit modes
  • Battery or mains powered
  • 10 point memory recall function
  • Process loops 4 to 20mA and 0 to 50mA
  • 24V loop driven voltage
  • 60 hour typical battery life between charger
  • Three levels of inching increments

Full List of Products Included

  • Time Electronics 1090 Portable Process Calibrator
  • Robust Carry Case
  • Instruction Manual

Time Electronics 1090 Technical Specifications

Thermocouple Type Temperature Range (°C) Accuracy (°C)
J -200 to 580 0.7

K

-200 to -150
-150 to 750

2.5
0.5

T

-200 to 0
0 to 400

1.5
0.4

R

50 to 400
400 to 1750

3.0
1.5

S

-50 to 100
100 to 1750

3.0
1.5

B

110 to 1000
1000 to 1800

3.5
1.5

N -100 to 890 0.6
E -50 to 400 0.4



Resolution

0.1°C or 0.1°F


Temperature Simulation
Thermocouple Type Temperature Range (°C) Accuracy (°C)

J

-210 to 150
150 to 1200

0.15
0.3

K

-270 to 190
190 to 1250

0.5
0.4

T

-200 to 150
150 to 400

0.4
0.5

R

-50 to 800
800 to 1750

0.8
2.0

S

-50 to 850
850 to 1750

0.9
2.0

B

100 to 1200
1200 to 1800

2.0
3.0

N

-270 to 260
260 to 1300

0.5
1.0

E -50 to 1000 0.3



Resolution

0.1°C or 0.1°F


Note: An additional correction representing the equivalent 1μV should be allowed for stray thermal emf effects (Temperature measure & simulation).

PT100 Simulation
14 set temperature points (°C) Accuracy
-100, -50, -20, 0, 20, 50, 100, 200, 300, 400, 500, 600, 700, 800 0.1% of resistance value (typically 0.5 °C)
PT100 Measure
Range Accuracy Resolution
200 to 700 °C, 2 wire. 0.2% of resistance value (typically 0.7 °C) 0.2°C (or 0.2°F)
Millivolt Measure
Range Resolution Accuracy Input Resistance

0 to +/- 30mV

10μV

0.05% of full scale ±1 digit

100kΩ

Millivolt Source
Range Resolution Accuracy Output Resistance
0 to 8mV 0.5μV +/- 4μV 10Ω
8 to 80mV 5μV 0.02% of full scale 10Ω
Milliamp Measure
Range Resolution Accuracy Input Resistance

0 to 60mA

20μA

0.05% of full scale ±1 digit

0.5Ω

Milliamp Source
Range Resolution Accuracy
0 to 8mA 0.5μA +/-10μA

8 to 80mA

5μA

0.02% of full scale

Further Features and Functions
Inching Three levels of increment, 0.1, 1 or 10 for °C/°F, and 1, 10, or 100 μV/ μA for voltage/current. The lowest of these represents the highest setting resolution and provides the most precise control of the output.

24V Process Loop Drive

A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at 60mA
(or a lower level if required). Max Load Specifications: 300Ω/80mA, 480Ω/50mA, 1.2kΩ/20mA

Memory recall & step

10 memory locations for non-volatile storage of values. Manual & AutoStep, rate adjustable from 1 to 10 sec/step


General Specifications

Cold Junction Compensation Accuracy 0.2°C. Resolution 0.1°C.
Operating Temperature -10 to 40°C (15 to 105°F)
Connections Industry standard 4mm screw terminals
Power A Ni-MH rechargeable battery pack gives approx. 60 hours continuous use. The mains recharger supplied gives full recharge in 11 hours. To conserve battery life a user inactivity power-down feature is included.
Dimensions H235 x W150 x D75mm
Weight 1.2kg
Supplied With Carry case, rechargeable battery pack (installed) with mains charger, and user manual
Optional Extras Calibration certificates traceable NPL and UKAS
Country of Origin UK
Time Electronics Portable Process Calibrator - Datasheet Datasheets Time Electronics 1090 Portable Process Calibrator - User Manual Manuals & Guides

Reviews

Additional Information
SKU 1090
Manufacturer Part Code 1090