All Time Electronics Products

Time Electronics 5030 Electrical Tester Calibrator

SKU
5030
Rating:
0%
(0)
Reward Points
:
5300
£6,360.00 £5,300.00
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Time Electronics 5030 Electrical Tester Calibrator

The Time Electronics 5030 Electrical Tester Calibrator can be used to calibrate RCD, loop, insulation, earth, and multifunction testers. It can accurately simulate RCD trip times, as well as measure currents produced by RCD testers, replicate loop impedances and auto-adjust for local line impedance, measure test voltages and currents, and provide insulation resistances. Intuitive menus and a central keypad make navigating the Time Electronics 5030 Electrical Tester Calibrator and selecting required measurement functions easy. Settings and measurements are visible on the Time Electronics 5030 Electrical Tester Calibrator’s large, clear, LCD.

Measurement Functions

Regional Test Sockets and Fault Detection

The Time Electronics 5030 Electrical Tester Calibrator can be fitted with a range of regional sockets via which the tester-under-investigation is connected. Once attached, you can check the tester’s loop and RCD tests. If the 5030 detects a fault it will automatically disconnect the output and warn the user; it is designed not to trip any RCDs on the local supply.

Loop Impedance with Auto Loop Measurement

Ten measurement points and high-power, precision resistors capable of withstanding up to 30A, ensure the Time Electronics 5030 Electrical Tester Calibrator can check a wide range of loop testers. To provide precise loop impedance calibration, the Time Electronics 5030 Electrical Tester Calibrator combines an accurate local loop measurement with the resistor value to give a loop impedance reading.

Precise RCD Trip Times

Simulate RCD trip times between 10 and 2000ms. For quick selection, predefined RCD trip times can be saved to the Time Electronics 5030 Electrical Tester Calibrator. Alternatively, you can set the required time via the front panel.

RCD Current Measurements

The Time Electronics 5030 Electrical Tester Calibrator measures the current of the instrument's applied RCD test current. It can measure current between 6mA and 1000mA and offers x0.5, x1, x2, and x5 multipliers up to 2500mA. The Time Electronics 5030 Electrical Tester Calibrator provides true-RMS AC current measurements; it can also measure DC test currents. Furthermore, to accommodate for models with a pre-test signal, the 5030 incorporates a pre-test delay to prevent false current measurements. Users can also configure a test current threshold (0 to 100% of nominal current) if required.

Insulation Resistance and Test Voltage Measurement

High-value resistors up to 2GΩ enable calibration of megohm meters. To automate multiple test points, resistance values can be set via the front panel or using a remote control. Additionally, the Time Electronics 5030 Electrical Tester Calibrator can check voltage measurement functions. It can measure test voltages up to 1kV while under 0.5mA or 1mA test conditions.

Continuity and Earth Resistance

Low ohm resistors mean the 5030 can be used to calibrate continuity functions present on most multifunction and insulation testers. The Time Electronics 5030 Electrical Tester Calibrator will also measure the applied test voltages and currents.

Mains Voltage and Frequency

The Time Electronics 5030 Electrical Tester Calibrator measures the local mains supply voltage and frequency. It uses these readings to verify the unit’s accuracy.

The Time Electronics 5030 Electrical Tester Calibrator is a simple-to-use, multifunctional, and precise electrical instrument calibrator.

Time Electronics 5030 Electrical Tester Calibrator Key Features

  • Calibrate RCD, loop, insulation, earth, and multifunction testers
  • Simulate RCD trip times
  • Measure currents produced by RCD testers
  • RCD current: 3mA to 2500 mA
  • RCD trip times: 10ms to 2000ms
  • Replicate loop impedance
  • Auto adjust for local line impedance
  • Loop: 50mΩ to 1.8kΩ
  • Measure test voltages and currents
  • Provides insulation resistances
  • Insulation: up to 2GΩ/ 1kV
  • Calibrate continuity functions
  • Continuity: 0.1Ω to 10kΩ
  • Intuitive menus
  • Central keypad
  • Large, clear LCD
  • Can be fitted with a range of regional sockets (please specify when you place your order)
  • RS-232 control
  • USB control
  • PC/ laptop control via EasyCal software
  • A simple-to-use, multifunctional, and precise electrical instrument calibrator

What’s Included?

  • Time Electronics 5030 Electrical Tester Calibrator
  • RS-232 Cable
  • USB Adaptor/ Cable

Time Electronics 5030 Electrical Tester Calibrator Technical Specifications 

Loop
Function Range / Values Resolution Accuracy
Loop Impedance
Resistor Values
1800, 330.0, 180.0, 33.00, 18.00, 3.300, 1.800,
0.330, 0.150, 0.050 Ω
4 digit ± 0.5 % of displayed value ± 30 mΩ
Local Loop Compensation 0 to 9.999 Ω 0.001 Ω ± 0.5 % of value ± 30 mΩ
Test Current 30 A max (200 ms) / 50 W max - -
RCD
Function Range / Values Resolution Accuracy
Trip Time 10 to 2000 ms 10 ms ± 0.5 ms
Current 6.000, 10.00, 30.00, 100.0, 300.0, 500.0, 1000 mA 4 digit ± 0.5 % of reading
± 1 % with x5 multiplier
Current Multipliers x0.5, x1, x2, x5 - -
Maximum Current 2500 mA - -
Waveforms AC, DC & half wave rectified - -
Phase Detection 0° or 180° - -
Pre Trigger Delay 0 to 2000 ms 10 ms -
Pre Trigger Threshold 0 to 100 % of nominal current 1 % -
Insulation 
Function Range / Values Resolution Accuracy
Resistance 1 MΩ to 2000 MΩ 1 MΩ 1 % of value
50 kΩ to 1990 kΩ 50 kΩ 1 % of value
Test Voltage Measurement
@ 0.5 mA or 1.0 mA Load
50.0 to 99.9 V DC 0.1 V 1 % of reading
100 to 1200 V DC 1 V 1 % of reading
Continuity
Function Range / Values Resolution Accuracy
Resistance 0.1 Ω to 100.0 Ω 0.1 Ω 1 % of value + 20 mΩ
250 Ω, 500 Ω, 1.00 kΩ, 2.50 kΩ, 5.00 kΩ & 10.0 kΩ 3 digit 1 % of value
Test Voltage Measurement
(input resistance 10 MΩ)
0.0 to 50.0 V DC 0.01 V 0.5 % of range
Test Current Measurement
(between 1 Ω and 2 Ω)
0 to 400 mA DC 0.1 mA 0.5 % of range
Power Dissipation 1 watt maximum - -
Voltage 
Function Range Resolution Accuracy
Line Voltage Measurement 200.0 to 260.0 V RMS 0.1 V 0.5 % of reading
Line Frequency Measurement 45.00 to 65.00 Hz 0.01 Hz 0.1 % of reading
General Specifications 
Warm up 30 minutes to full accuracy
Settling time Less than 5 seconds
Standard interfaces RS-232 and USB
Temperature performance Operating: 10 to 35 °C,
Full spec: 23 °C ± 5 °C, Storage: -10 °C to 50 °C
Operating humidity/altitude < 80 % non condensing / Altitude: 0 to 3 km.
Non operating altitude: 3 to 12 km.
Line power 220 to 240 V AC 50 Hz.
Power consumption 200 W maximum
Dimensions / Weight W 430 x H 155 x D 255 mm / Weight: 8 kg
Time Electronics 5030 Electrical Tester Calibrator - Datasheet Datasheets Time Electronics EasyCal Calibration Software - Brochure Brochures & Catalogues

Reviews

Additional Information
SKU 5030
Manufacturer Part Code 5030