Suitable for troubleshooting full-scale electrical equipment, the Teledyne FLIR CM85-2 True-RMS Power Clamp Meter is an industrial power clamp with advanced power analysis and variable frequency drive (VFD) filtering functions.
Equipped with a wide AC/DC voltage range, ±1% accuracy, and capable of testing harmonics, inrush, current, and phase rotation, the Teledyne FLIR CM85-2 True-RMS Power Clamp Meter is ideal for accurately analysing voltage in complex machinery. VFD mode improves accuracy when you are working on VFD-controlled equipment while a true-RMS AC current range of up to 1000 A enables multiple conductor measurements.
Data may be streamed in real-time from your Teledyne FLIR CM85-2 True-RMS Power Clamp Meter to a smartphone/tablet with the METERLiNK App installed. A Bluetooth range of 10m allows you to leave the Teledyne FLIR CM85-2 True-RMS Power Clamp Meter in place while you take readings from a safe location.
Via the METERLiNK App you can also save data, set alarm thresholds, visualise trends, and create reports which may be shared with colleagues.
Designed to deliver convenience and ease of operation, the ergonomic Teledyne FLIR CM85-2 True-RMS Power Clamp Meter includes dual LED lights, eliminating the need to carry an additional torch.
The Teledyne FLIR CM85-2 True-RMS Power Clamp Meter is an ergonomic, easy-to-use electrical troubleshooting tool with an eclectic array of measurement capabilities.
Measurement Ranges and Accuracy | |
Voltage DC | 99.99 V, ±(0.7% + 2 digits) 999.9 V, ±(0.7% + 2 digits) |
Voltage AC | 0.05 V to 99.99 V, ±(1.0% + 5 digits) 999.9 V, 50 Hz to 500 Hz |
VFD, ACV | 0.05 V to 99.99 V, 50 Hz to 60 Hz ±(1% + 5 digits) 999.9 V, 50 Hz to 60 Hz ±(1% + 5 digits) |
Current DC | 99.99 A, ±(2% + 0.5 A) 999.9 A, ±(2% + 5 digits) |
Current AC | 0.10 A to 99.99 A, 50 Hz to 60 Hz ±(2% + 5 digits) 999.9 A, >60 Hz to 400 Hz ±(2.5% + 5 digits) |
VFD, ACA | 0.10 A to 99.99 A, 50 Hz to 60 Hz ±(2% + 5 digits) 999.9 A, 50 Hz to 60 Hz ±(2% + 5 digits) |
Peak Hold ACV | 140.0 V, ±(3.0% + 15 digits) 1400 V, ±(3.0% + 15 digits) |
Peak Hold ACA | 140.0 A, ±(3.5% + 15 digits) 1400 A, ±(3.5% + 15 digits) |
Frequency | 20.00 Hz to 99.99 Hz, ±(0.5% + 3 digits) 20.0 Hz to 999.9 Hz, ±(0.5% + 3 digits) 0.020 kHz to 9.999 kHz, ±(0.5% + 3 digits) |
Total harmonic distortion ACA/ACV | 99.9%, ±(3.0% + 10 digits) |
Harmonic distortion H01–H12 | 99.9%, ±(5% + 10 digits) |
Harmonic distortion H13–H25 | 99.9%, ±(10% + 10 digits) |
Inrush current ACA | 99.99 A, ±(3% + 0.3 A) 999.9 A, ±(3% + 5 digits) |
Watts DC | 9.999 kW (10 V, 5 A min), ±(3% + 0.05 kW) 99.99 kW (10 V, 5 A min), ±(3% + 0.5 kW) 999.9 kW (10 V, 5 A min), ±(3% + 10 digits) |
Watts AC | 9.999 kW (10 V, 5 A min), ±(3% + 10 digits) 99.99 kW (10 V, 5 A min), ±(3% + 10 digits) 999.9 kW (10 V, 5 A min), ±(3% + 10 digits) |
Power factor | -1.00 to 0.00 to +1.00, ±3° ±1 digit |
Resistance | 999.9 Ω, ±(1.0% + 5 digits) 9.999 kΩ, ±(1.0% + 3 digits) 99.99 kΩ, ±(1.0% + 3 digits) |
Continuity | 999.9 Ω, ±(1.0% + 5 digits) |
Diode | 0.40 V to 0.80 V, ±0.1 V |
Capacitance | 3.999 μF, ±(1.9% + 8 digits) 39.99 μF, ±(1.9% + 8 digits) 399.9 μF, ±(1.9% + 8 digits) 3.999 mF, ±(1.9% + 8 digits) |
Measuring rate | 3 times per second |
Meter Data | |
Jaw opening | 45 mm (1.77 in) |
Bluetooth range | 10 m (32 ft) |
Category rating | CAT IV-600 V, CAT III-1000 V |
Data recording | Available via METERLiNK App |
Drop test | 1.2 m (4 ft) |
Certifications | |
Certifications | UL, CE, FCC, IC, UKCA, CSAUS |
Complies with Safety Standards | IEC 61010-1:2010, IEC 61010-2-032:2012, IEC 61010-2-033:2012 |
EMC | FCC: 47 CFR Part 15 Subpart B CE: EN IEC 61326-1:2021 EN IEC 61326-2-2:2021 EN 301 489-1 V2.2.3 (2019-11) EN 301 489-17 V3.2.4 (2020-09) RF: ETSI EN 300 328 V2.2.2 EN 62479:2010 EN 50663:2017 |
Power System | |
Power requirements | 6 × 1.5 V AAA alkaline batteries |
Battery life | 50 hours with alkaline batteries (backlight, worklight, and Bluetooth off) |
Auto power off | Approx. 30 minutes |
Environmental Data | |
Operating ambient temperatures and relative humidity |
0°C to 10°C (32°F to 50°F) (non‐condensing) 10°C to 30°C (50°F to 86°F) (≤80% RH) 30°C to 40°C (86°F to 104°F) (≤75% RH) 40°C to 50°C (104°F to 122°F) (≤45% RH) |
Storage temperature and relative humidity |
-10°C to 50°C (14°F to 122°F). 0 to 80% RH (batteries not fitted) |
Temperature coefficient | 0.2 × (specified accuracy)/° C, <18°C, >28°C. |
Operating altitude | 2000 m (6562 ft) |
Pollution degree | 2 |
Shock vibration | Random vibration per MIL‐PRF‐28800f Class 2 (5 to 55 Hz, 3 g maximum) |
Meter Physical Data | |
Weight | 0.65 kg (1.43 lb), including batteries |