Available with a selection of lenses as well as a range of optional extras, the FLIR A70 Automation Thermal Camera is an infrared-imaging automation camera with an advanced smart sensor configuration, built-in analytics, and onboard alarms. It is suitable for condition monitoring and early fire detection.
Delivering detailed, low-noise thermal imaging incorporating temperature data, the FLIR A70 Advanced Smart Sensor Automation Thermal Camera has an IR resolution of 640 x 480px and can measure temperatures between -20°C and +1000°C to an approximate accuracy of ±2°C/2%. Exact temperature data can be extracted from each pixel using FLIR’s Atlas SDK.
The FLIR A70 Advanced Smart Sensor Automation Thermal Camera also supports optional MSX imaging when it is configured to include an optional built-in visual camera. MSX imaging overlays digital details onto thermal images thereby improving clarity. Please contact our Sales Team for further details.
FLIR’s advanced smart sensor configuration is perfect for those who require built-in analytics. Cameras with this configuration allow you to transfer complete, actional results to your own system. The advanced smart sensor configuration supports the following functions and features:
The thermal sensors communicate with standard industrial protocols delivering seamless integration into video management systems, as well as HMI and SCADA systems. An SNMP trap and advanced firewall protection mean multiple network devices can work together securely. The Teledyne FLIR A70 Advanced Smart Sensor Automation Thermal Camera also supports simple configuration via a standard web browser.
Optional ONVIF S enables simultaneous VMS video and alarm integrations. Please contact our Sales Team for more details.
The FLIR A70 can be easily installed in a variety of demanding or challenging settings. This is because it is compact, lightweight, rugged (IP66), features heavy-duty M8/12 connectors, and is compatible with an array of mounting options.
Ideal for protecting assets, improving safety, maximising uptime, and minimising maintenance costs, the FLIR A70 Automation Thermal Camera is a flexible, reliable, temperature-measuring thermal automation camera.
Digital I/O connector type | M12 12-pin A-coded, Male (shared with external power) |
Digital Inputs | 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V |
Digital Output Purpose |
|
Digital Outputs | 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC) |
Encoding | Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric |
Ethernet Interface | Wired, Wi-Fi (optional) |
WiFi | Optional feature purchased separately. RP-SMA, female connector |
EMC |
|
f-number | 1.4 |
Image Frequency | 30 Hz |
Thermal Sensitivity/NETD | <35 mK |
Accuracy | ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F) |
Alarm Functions | 10 Spotmeters 10 Boxes and Mask polygons (total number) 3 Deltas (difference any value/reference/external lock) 2 Isotherm (above/below/interval) 2 Iso-coverage 1 Reference temperature 2 Lines 1 Polyline |
Alarm Output | Digital out E-mail (SMTP) (push) EtherNet/IP (pull) File transfer (FTP) (push) Modbus TCP Client (push) Modbus TCP Server (pull) MQTT (push) ONVIF events (push) Query over RESTful API (pull) Store image or video |
Communication & Data Storage | |
Digital I/O connector type | M12 12-pin A-coded, Male (shared with external power) |
Digital I/O isolation voltage | 500 VRMS |
Digital input purpose | NUC, NUC disable, alarm |
Digital Inputs | 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V |
Digital Output Purpose |
|
Digital Outputs | 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC) |
Encoding | Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric |
Ethernet | For control, result, image, and power |
Ethernet Communication | TCP/IP socket-based FLIR proprietary |
Ethernet Connector Type | M12 8-pin X-coded, female; RP-SMA, female |
Ethernet Interface | Wired, Wi-Fi (optional) |
Ethernet Power | Power over Ethernet, PoE IEEE 802.3af class 3 |
Ethernet Protocols |
|
Ethernet Standard | IEEE 802.3 |
Ethernet Type | 1000 Mbps |
Image Storage | NA |
Multicast | Yes |
RS-232 | M8 A-coded, male connector |
WiFi | Optional feature purchased separately. RP-SMA, female connector |
Imaging & Optical | |
Contrast Enhancement | FSX® / Histogram equalization (IR only) |
Detector Pitch | 12 µm |
Field of view (FOV) | Lens dependent |
f-number | 1.4 |
Focal Length | 4.1 mm (0.16 in) |
Focal Plane Array (FPA) | Uncooled microbolometer |
Focus | Fixed, adjustable with included tool |
Image Frequency | 30 Hz |
IR Resolution | 640 × 480 |
Minimum Focus Distance | 0.1 m (0.33 ft) |
MSX | Yes, included in visual camera option |
Overlay | With/Without |
Radiometric IR video streaming | RTSP protocol |
Readout |
Measurement results:
|
Spectral Range | 7.5–14 µm |
Streaming Resolution | RTSP Video stream 0: 640 × 480 pixels RTSP Video stream 1: 1280 × 960 pixels Radiometric stream: 464 × 348 pixels |
Thermal Sensitivity/NETD | <35 mK |
Video Streaming | RTSP protocol |
Visible Camera | Optional accessory |
Measurement & Analysis | |
Accuracy | ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F) |
Alarm Functions | 10 Spotmeters 10 Boxes and Mask polygons (total number) 3 Deltas (difference any value/reference/external lock) 2 Isotherm (above/below/interval) 2 Iso-coverage 1 Reference temperature 2 Lines 1 Polyline |
Alarm Output | Digital out E-mail (SMTP) (push) EtherNet/IP (pull) File transfer (FTP) (push) Modbus TCP Client (push) Modbus TCP Server (pull) MQTT (push) ONVIF events (push) Query over RESTful API (pull) Store image or video |
Atmospheric transmission correction | Based on inputs of distance, atmospheric temperature, and relative humidity |
Automatic hot & cold detection | Max./min. temperature value and position shown within Box |
Measurement Corrections | Global object parameters; local parameters per analyze function; external Black-body correction |
Measurement Presets | Yes |
Measurement Tools | 10 spotmeters, 10 boxes and mask polygons (total number), 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline |
Object Temperature Range | –20 to 175°C (–4 to 347°F) 175 to 1000°C (347 to 1832°F) |
General | |
Base Mounting | 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate |
Housing material | Aluminium |
Size (L x W x H) | 107 × 67 × 57 mm (4.21 × 2.64 × 2.24 in) |
Weight | 519g (1.14lb) without bottom cooling plate |
Environmental & Certifications | |
Corrosion |
|
EMC |
|
Encapsulation | IEC 60529 and IP66 |
Humidity (Operating and Storage) | IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles EN60068-2-38 |
Operating Temperature Range | –20 to 50°C (–4 to 122°F) Bottom cooling plate is needed in temperatures above 40°C (104°F). Maximum internal temperature sensor: 70°C (158°F) |
Radio Spectrum |
|
Shock | IEC 60068-2-27, 25 g |
Tripod Mounting | 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate |
Vibration |
|
Power | |
External Power Operation | 24/48 V DC 8 W max |
External Voltage | Allowed range 18–56 V DC |
Power Connection | M12 12-pin A-coded, male (shared with Digital I/O) |
Power Consumption |
|
User Interface | |
Web interface | Yes |