Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
This product is an optional loading unit for use with the PCU1-SP, capable of generating current up to 200A.
Alternative versions of this product which generate up to 2000A or 5000A are also available.
Supply Requirements | |||||
---|---|---|---|---|---|
Loading Unit | Open Circuit Voltage | Load Current | Max Time For Load Current | Supply Current | |
NLU5000 | 2.3V | 3000A | 5 minutes | 30A | |
5000A | 40 seconds | 50A | |||
4.6V | 1500A | 5 minutes | 30A | ||
2500A | 40 seconds | 50A | |||
9.2V | 750A | 5 minutes | 30A | ||
1250A | 50 seconds | 50A | |||
NLU2000 | 3.5V | 1200A | 5 minutes | 18A | |
2000A | 40 seconds | 30A | |||
6.9V | 600A | 5 minutes | 18A | ||
1000A | 40 seconds | 30A | |||
13.8V | 300A | 5 minutes | 18A | ||
500A | 40 seconds | 30A | |||
NLU200 | 60V | 80A | 5 minutes | 21A | |
200A | 40 seconds | 50A | |||
120V | 40A | 5 minutes | 21A | ||
100A | 40 seconds | 50A | |||
Loading Unit Outputs | |||||
Loading Unit | Open Circuit Voltage | Continous Current | Intermittent Current | ||
5 Min On/15 Min Off | 1 Min On/15 Min Off | 40s On/15 Min Off | |||
NLU5000 | 2.3V | 1500A | 3000A | 4500A | 5000A |
4.6V | 750A | 1500A | 2250A | 2500A | |
9.2V | 375A | 750A | 1125A | 1250A | |
NLU2000 | 3.5V | 600A | 1200A | 1800A | 2000A |
6.9V | 300A | 600A | 900A | 1000A | |
13.8V | 150A | 300A | 450A | 500A | |
NLU200 | 60V | 40A | 80A | 160A | 200A |
120V | 20A | 40A | 80A | 100A |