All T and R Products

T&R 50ADM-P Secondary Current Injection Test Set in Pelicase

SKU
242
Rating:
0%
(0)
Call For Pricing

This is a bulky item and requires a shipping quote

Black Friday - Free Items With Orders Over £300

Black Friday Freebies
Spend £100 to £749.99
LED Head Torch (Worth: £15.99)

Spend Over £750
Free LED Head Torch & Extendable Flash Light (Worth: £35.98)

Prices Ex VAT

or Call 01642 931 329 to discuss product options

T&R 50ADM-P Secondary Current Injection Test Set

T&R 50ADM-P Secondary Current Injection Test Set

The T&R 50ADM-P Secondary Current Injection Test Set is a robust tester for current injection testing and relay phase shifting. It can be used to check protective relays, circuit breakers, and other critical components. To this end, the T&R 50ADM-P provides high-accuracy current and voltage outputs up to 50A and 18V respectively. The 50ADM-P also offers true-RMS metering and an advanced timing system with automatic range selection and a 1ms resolution. Digital metering and an intuitive interface ensure the T&R 50ADM-P is easy to use even in complex testing scenarios. USB ports enable data exportation while a solid-state current control device protects the test set and component under test by automatically shutting off during a trip event. Compact, yet powerful, the T&R 50ADM-P Secondary Current Injection Test Set delivers precision and ease of use. It is ideal for professionals working in utility and industrial settings.

Tests & Measurements

The T&R 50ADM-P Secondary Current Injection Test Set provides test currents between 0 and 50A and test voltages up to 18V. Its true-RMS metering ascertains accurate readings with a one-cycle capture. Furthermore, an advanced timing system with a 1ms resolution automatically selects the required range for trip, reset, and reclose timing. The T&R 50ADM-P Secondary Current Injection Test Set also supports the following:

  • Variable auxiliary AC voltage/current output with phase shift
  • Auxiliary meeting input (V, f, φ, P, S, PF, CT ration and harmonics)
  • Variable auxiliary output 12-220V DC
  • Current limit mode for fine control

Applications

Detailed, eclectic testing makes the T&R 50ADM-P perfect for validating equipment performance and ensuring compliance with industry standards. It is ideal for conducting primary injections, stability tests, or detailed circuit breaker analyses and is suitable for determining the following:

  • Distance protection (phase at time)
  • Volts/Hz
  • Check sync
  • Under/over voltage
  • Directional power
  • Under-current/-power
  • Field relay
  • Negative sequence
  • Overcurrent relay
  • Instantaneous overcurrent
  • Ground fault relay
  • Voltage restrained overcurrent
  • IDMT overcurrent relay
  • Power factor relay

Safe, Simple-to-Use, Solid Design

The T&R 50ADM-P Secondary Current Injection Test Set is compact and easy to carry. It includes several features that enhance its ease of use, connectivity, and safety.

Easy to Use with Enhanced Connectivity

An intuitive interface combined with digital metering makes the T&R 50ADM-P simple to operate. To deliver streamlined and efficient testing, metering and control functions are all accessible via the control unit while the loading unit provides a high-current output.

Additionally, a USB port facilitates connection to a keyboard or printer, offering users more connectivity and control options. USB host ports simplify data storage and management, allowing you to export data into a spreadsheet for detailed waveform and harmonic analysis on your laptop/PC. This makes conducting analysis and creating reports easy.

Safety Optimised

The T&R 50ADM-P includes a solid-state current control device that automatically shuts off the secondary current injection test set during a trip event. This protects both the T&R 50ADM-P and the device under test during rigorous testing.

Powerful, user-centric, and precise, the T&R 50ADM-P Secondary Current Injection Test Set meets rigorous testing demands efficiently and accurately.

Key Features

  • A robust tester for current injection testing and relay phase shifting
  • Check protective relays, circuit breakers, and other critical components
  • Test current: 0-50A
  • Test Voltage: up to 18V
  • True-RMS metering delivers accurate readings with a one-cycle capture
  • Advanced timing system automatically selects the required range of trip, reset, and reclose timing
  • Advanced timing system resolution: 1ms
  • Variable auxiliary AC voltage/current output with phase shift
  • Auxiliary meeting input (V, f, φ, P, S, PF, CT ration and harmonics)
  • Variable auxiliary output 12-220V DC
  • Current limit mode for fine control
  • Validate equipment performance
  • Ensure compliance with industry standards
  • Primary injections
  • Stability tests
  • Detailed circuit breaker analysis
  • Distance protection (phase at time)
  • Volts/Hz
  • Check sync
  • Under/over voltage
  • Directional power
  • Under-current/-power
  • Field relay
  • Negative sequence
  • Overcurrent relay
  • Instantaneous overcurrent
  • Ground fault relay
  • Voltage restrained overcurrent
  • IDMT overcurrent relay
  • Power factor relay
  • Compact
  • Easy to carry
  • Intuitive interface
  • Digital metering
  • Control unit includes metering and control functions
  • Loading unit provides a high-current output
  • USB port for connecting a keyboard/printer
  • USB host ports simplify data storage and management
  • Export data into a spreadsheet for detailed waveform and harmonic analysis on your laptop/PC
  • Solid-state current control device automatically shuts off the test set during a trip event
  • Solid-state current control device improves safety during rigorous testing
  • SCITS meets rigorous testing demands efficiently and accurately

What’s Included?

  • T&R 50ADM-P Secondary Current Injection Test Set
  • Output Lead Set
  • Mains Lead
  • Spare Fuses
  • USB Keyboard
  • USB Memory Key
  • Calibration Certificate from T&R
  • Operating Manual

T&R 50ADM-P Secondary Current Injection Test Set Technical Specifications 

Main Output 
Range Continuous 5 minutes 1 minute
3.5V 16A 32A 50A
18V 4A 8A 12A
Protection over current trip, duty cycle trip, thermal monitoring.
Metering 
Range Resolution Trip current Accuracy
5.000A 0.001A 5.25A ±0.6%rdg+5d
20.00A 0.01A 21A ±0.6%rdg+5d
50.00A 0.01A 52.5A ±0.6%rdg+5d
Protection: over current trip, duty cycle trip, thermal monitoring.
Auxiliary DC Output
Range Maximum A Continuous Rating 
12-60V 1A 25W
60-220V 0.23A 25W
Protection: current limit.
Phase-shifting AC Output
Frequency range 45—100Hz
Phase angle 0—±180°
Range  Maximum Current  Current 
No Load Full Load Continuous 5 min on/ 15 min
off
0-130V 144V 125V 0.23A 0.46A
0-260V 288V 250V 0.11A 0.23A
0-6V 6.6V 5V 5A 10A
Protection: current limit & electronic trip.
Auxiliary Metering Inputs
Protection: fuse on current input.
Timing System
Mode Timer Start Timer Stop
Internal start Press ‘ON’ Contact 1 or 2 change
1 contact Contact 1 1st
change
Contact 1 2nd change
2 contacts Contact 1 change Contact 2 change
MART (Multiple Auto -Reclose Timing) Contact 2 change Contact 1 change
Current operated Current > 10% of
metering range
Current <10% of
metering range
Pulse Press ‘ON’ 200ms
Aux AC Aux AC on/switch
freq to φ/ switch
φ to freq
Contact 1 or 2 change
Range 0-999.999s/9999.99s/99999.9s autoranging
Resolution 1/10/100ms
Accuracy 0.01%rdg+2d (+4d current operated mode)
Contact o/c 24V
Contact s/c 20mA
Vdc 24—240V
Note Each contact circuit will auto-select for normally open or
normally closed contacts. A DC voltage of 24—240Vdc may
also be used to trigger either timer channel. Contact state is
shown by an LED.
Supply Requirements 115V/230V ±10% auto-select 50/60Hz 1ph 2300VA max.
Lead Set specifications
The 50ADM-P is supplied with a high quality lead set including: 2 x 5m 10mm2 50A leads terminated in M10 fork crimps
2 x 5m, 2 x 0.5m 2.5mm2 25A leads terminated in 4mm plugs
1 x 5m 2 core auxiliary leads terminated in 4mm plugs.
Safety An earth terminal is provided for connection to a local earth. The unit is designed to comply with BSEN61010 and is CE marked.
Temperature Range
Storage -20°C to 60°C
Operating 0°C to 45°C
Dimensions 464x 366 x 176mm
Weight
Main unit 13.2kg
Full kit with backpack & leads 16.6kg
T&R 50ADM-P Secondary Current Injection Test Set - Datasheet Datasheets T&R 50ADM-P Secondary Current Injection Test Set - Operating & Maintenance Manual Manuals & Guides

Reviews

Additional Information
SKU 242
Manufacturer Part Code 242