T&R 50ADM-P Secondary Current Injection Test Set
The T&R 50ADM-P Secondary Current Injection Test Set is a robust tester for current injection testing and relay phase shifting. It can be used to check protective relays, circuit breakers, and other critical components. To this end, the T&R 50ADM-P provides high-accuracy current and voltage outputs up to 50A and 18V respectively. The 50ADM-P also offers true-RMS metering and an advanced timing system with automatic range selection and a 1ms resolution. Digital metering and an intuitive interface ensure the T&R 50ADM-P is easy to use even in complex testing scenarios. USB ports enable data exportation while a solid-state current control device protects the test set and component under test by automatically shutting off during a trip event. Compact, yet powerful, the T&R 50ADM-P Secondary Current Injection Test Set delivers precision and ease of use. It is ideal for professionals working in utility and industrial settings.
Tests & Measurements
The T&R 50ADM-P Secondary Current Injection Test Set provides test currents between 0 and 50A and test voltages up to 18V. Its true-RMS metering ascertains accurate readings with a one-cycle capture. Furthermore, an advanced timing system with a 1ms resolution automatically selects the required range for trip, reset, and reclose timing. The T&R 50ADM-P Secondary Current Injection Test Set also supports the following:
- Variable auxiliary AC voltage/current output with phase shift
- Auxiliary meeting input (V, f, φ, P, S, PF, CT ration and harmonics)
- Variable auxiliary output 12-220V DC
- Current limit mode for fine control
Applications
Detailed, eclectic testing makes the T&R 50ADM-P perfect for validating equipment performance and ensuring compliance with industry standards. It is ideal for conducting primary injections, stability tests, or detailed circuit breaker analyses and is suitable for determining the following:
- Distance protection (phase at time)
- Volts/Hz
- Check sync
- Under/over voltage
- Directional power
- Under-current/-power
- Field relay
- Negative sequence
- Overcurrent relay
- Instantaneous overcurrent
- Ground fault relay
- Voltage restrained overcurrent
- IDMT overcurrent relay
- Power factor relay
Safe, Simple-to-Use, Solid Design
The T&R 50ADM-P Secondary Current Injection Test Set is compact and easy to carry. It includes several features that enhance its ease of use, connectivity, and safety.
Easy to Use with Enhanced Connectivity
An intuitive interface combined with digital metering makes the T&R 50ADM-P simple to operate. To deliver streamlined and efficient testing, metering and control functions are all accessible via the control unit while the loading unit provides a high-current output.
Additionally, a USB port facilitates connection to a keyboard or printer, offering users more connectivity and control options. USB host ports simplify data storage and management, allowing you to export data into a spreadsheet for detailed waveform and harmonic analysis on your laptop/PC. This makes conducting analysis and creating reports easy.
Safety Optimised
The T&R 50ADM-P includes a solid-state current control device that automatically shuts off the secondary current injection test set during a trip event. This protects both the T&R 50ADM-P and the device under test during rigorous testing.
Powerful, user-centric, and precise, the T&R 50ADM-P Secondary Current Injection Test Set meets rigorous testing demands efficiently and accurately.
Key Features
- A robust tester for current injection testing and relay phase shifting
- Check protective relays, circuit breakers, and other critical components
- Test current: 0-50A
- Test Voltage: up to 18V
- True-RMS metering delivers accurate readings with a one-cycle capture
- Advanced timing system automatically selects the required range of trip, reset, and reclose timing
- Advanced timing system resolution: 1ms
- Variable auxiliary AC voltage/current output with phase shift
- Auxiliary meeting input (V, f, φ, P, S, PF, CT ration and harmonics)
- Variable auxiliary output 12-220V DC
- Current limit mode for fine control
- Validate equipment performance
- Ensure compliance with industry standards
- Primary injections
- Stability tests
- Detailed circuit breaker analysis
- Distance protection (phase at time)
- Volts/Hz
- Check sync
- Under/over voltage
- Directional power
- Under-current/-power
- Field relay
- Negative sequence
- Overcurrent relay
- Instantaneous overcurrent
- Ground fault relay
- Voltage restrained overcurrent
- IDMT overcurrent relay
- Power factor relay
- Compact
- Easy to carry
- Intuitive interface
- Digital metering
- Control unit includes metering and control functions
- Loading unit provides a high-current output
- USB port for connecting a keyboard/printer
- USB host ports simplify data storage and management
- Export data into a spreadsheet for detailed waveform and harmonic analysis on your laptop/PC
- Solid-state current control device automatically shuts off the test set during a trip event
- Solid-state current control device improves safety during rigorous testing
- SCITS meets rigorous testing demands efficiently and accurately
What’s Included?
- T&R 50ADM-P Secondary Current Injection Test Set
- Output Lead Set
- Mains Lead
- Spare Fuses
- USB Keyboard
- USB Memory Key
- Calibration Certificate from T&R
- Operating Manual
T&R 50ADM-P Secondary Current Injection Test Set Technical Specifications
Main Output | ||||
Range | Continuous | 5 minutes | 1 minute | |
3.5V | 16A | 32A | 50A | |
18V | 4A | 8A | 12A | |
Protection | over current trip, duty cycle trip, thermal monitoring. | |||
Metering | ||||
Range | Resolution | Trip current | Accuracy | |
5.000A | 0.001A | 5.25A | ±0.6%rdg+5d | |
20.00A | 0.01A | 21A | ±0.6%rdg+5d | |
50.00A | 0.01A | 52.5A | ±0.6%rdg+5d | |
Protection: | over current trip, duty cycle trip, thermal monitoring. | |||
Auxiliary DC Output | ||||
Range | Maximum A | Continuous Rating | ||
12-60V | 1A | 25W | ||
60-220V | 0.23A | 25W | ||
Protection: | current limit. | |||
Phase-shifting AC Output | ||||
Frequency range | 45—100Hz | |||
Phase angle | 0—±180° | |||
Range | Maximum Current | Current | ||
No Load | Full Load | Continuous | 5 min on/ 15 min off |
|
0-130V | 144V | 125V | 0.23A | 0.46A |
0-260V | 288V | 250V | 0.11A | 0.23A |
0-6V | 6.6V | 5V | 5A | 10A |
Protection: | current limit & electronic trip. | |||
Auxiliary Metering Inputs | ||||
Protection: | fuse on current input. | |||
Timing System | ||||
Mode | Timer Start | Timer Stop | ||
Internal start | Press ‘ON’ | Contact 1 or 2 change | ||
1 contact | Contact 1 1st change |
Contact 1 2nd change | ||
2 contacts | Contact 1 change | Contact 2 change | ||
MART (Multiple Auto -Reclose Timing) | Contact 2 change | Contact 1 change | ||
Current operated | Current > 10% of metering range |
Current <10% of metering range |
||
Pulse | Press ‘ON’ | 200ms | ||
Aux AC | Aux AC on/switch freq to φ/ switch φ to freq |
Contact 1 or 2 change | ||
Range | 0-999.999s/9999.99s/99999.9s autoranging | |||
Resolution | 1/10/100ms | |||
Accuracy | 0.01%rdg+2d (+4d current operated mode) | |||
Contact o/c | 24V | |||
Contact s/c | 20mA | |||
Vdc | 24—240V | |||
Note | Each contact circuit will auto-select for normally open or normally closed contacts. A DC voltage of 24—240Vdc may also be used to trigger either timer channel. Contact state is shown by an LED. |
|||
Supply Requirements | 115V/230V ±10% auto-select 50/60Hz 1ph 2300VA max. | |||
Lead Set specifications | ||||
The 50ADM-P is supplied with a high quality lead set including: | 2 x 5m 10mm2 50A leads terminated in M10 fork crimps | |||
2 x 5m, 2 x 0.5m 2.5mm2 25A leads terminated in 4mm plugs | ||||
1 x 5m 2 core auxiliary leads terminated in 4mm plugs. | ||||
Safety | An earth terminal is provided for connection to a local earth. The unit is designed to comply with BSEN61010 and is CE marked. | |||
Temperature Range | ||||
Storage | -20°C to 60°C | |||
Operating | 0°C to 45°C | |||
Dimensions | 464x 366 x 176mm | |||
Weight | ||||
Main unit | 13.2kg | |||
Full kit with backpack & leads | 16.6kg |