The T&R 50A-3PH is a three-phase secondary current injection system, allowing engineers to check the correct operation of protective systems.
Simple to use with a clear interface with colour-coded sections, the 50A-3PH outputs 3-phase current up to 50A and has a selectable output voltage of up to 18V. The system has three true RMS metering ranges, allowing the full scale of the meter and trip level to be set independently of the selected output.
This product is ideal for testing both single- and three-phase secondary protection such as over- and under-current relays, IDMT relays, auto reclosers, time delay relays, earth fault relays, miniature circuit breakers, power relays, tripping relays and thermal relays.
The 50A-3PH is equipped with an adjustable timing system with range of 0 to 999.999s. This function includes several starting modes, including internal start, single contact, dual contact, and current operation.
An optional printer or PC can be connected to the 50A-3PH via a built-in RS232 port. This product’s link output also provides a phase lock reference for a DVS3 phase-shifting voltage source.
Key Features
- Output three phase current from 0 to 50A
- Simple to use with easy-to-understand interface
- 0-50A per phase output current
- True RMS digital metering
- Memory ammeter
- Multifunction timing system
- Auxiliary metering input
- Large-size backlight LCD display
- Thermal and overcurrent protection
- Compact, portable design
What’s Included?
- T & R 50A-3PH Current Injector
- Choice of Metal or Pelicase
- Operating Manual
- Output Lead Set
- Mains Lead
- Spare Fuse Set
Optional Accessories
These products are NOT included as standard. Please call for more information or to order these accessories.
- Delta-Star Supply Transformer – allows operation from 115V, 230V, 400V and 440V 3 wire supplies
- Filter Unit
- Printer
- Leadset Carry Case
T & R 50A-3PH Technical Specifications
Main Output | |||
---|---|---|---|
Range | Continuous | 5 Minutes | 1 Minute |
3.5V | 16A | 32A | 50A |
18V | 4A | 8A | 12A |
The above intermittent on times must be followed by an off time of 15 minutes, and are based on ambient temperature of 25°C | |||
Metering | |||
Range | Resolution | Trip Current | Accuracy |
5.000A | 0.001A | 5.25A | ±0.6% rdg + 5d |
20.00A | 0.01A | 21A | ±0.6% rdg + 5d |
50.00A | 0.01A | 52.5A | ±0.6% rdg + 5d |
Auxiliary Metering Inputs | |||
Setting | Range | Resolution | Accuracy |
Volts (AC) | 270V | 0.1V | ±0.7% rdg + 5d |
Amps (AC) | 5.000A | 1mA | ±0.7% rdg + 5d |
Phase ± 180° | 0.1° | ±3° | - |
Frequency | 20 to 1000Hz | 0.1Hz | ±0.2% rdg + 1d |
Further tech specs are available in the attached documentation.