TP Solid / Dry Block-Temperature Calibrator
With the temperature calibrators of the TP Solid series, the main focus is on flexibility: In addition to dry block calibrators, they also include calibration baths, with which almost any temperature sensor can be calibrated irrespective of its shape. Both can be operated easily and intuitively.
When being used as a fluid bath calibrator, the temperature sensors are directly immersed in the calibration liquid. This creates a direct temperature link between the calibrator and the devices under test without an insulating air gap.
All TP Solid temperature calibrators are additionally equipped with a serial interface for computer-assisted monitoring of the calibration process. This flexibility in combination with the easy operation makes the TP Solid series ideal for use in machinery and plant engineering.
- ✓ Compact design for on-site use
- ✓ Simple calibration without consideration of viscosities, flash points, or outgassing
- ✓ Large calibration volume for the simultaneous calibration of several DUT
- ✓ Optimum thermal coupling from block to DUT due to SIKA calibration inserts
Whether for on-site use in the workshop, in the measuring and test room, or laboratory, SIKA temperature calibrators can be used everywhere. A wide range of industries and various application areas are covered.
- • Assembly, commissioning
- • Manufacturing, production
- • Maintenance, service
- • Quality assurance, test equipment monitoring
- • Repair
Dry Block Function
The dry block function was developed to easily calibrate the temperature in lab and field applications. The optimum thermal coupling from block to DUT is achieved by the correct calibration insert.
Ideally, the inner diameter of the borehole in the calibration insert is 0.5 mm larger than the outer diameter of the DUT. With the help of the calibration insert almost all straight temperature sensors with different lengths and diameters can be calibrated.
The dry block covers the entire temperature range without changing the calibration medium. The user does not have to consider viscosities, flash points, or outgassing.
TP 17165S | TP 17166S-STD | TP 17200S | TP 17450S-STD | TP 17650S | |
---|---|---|---|---|---|
Temperature Range | -35...165 °C at ambient temperature 20 °C | -30...165 °C at ambient temperature 20 °C | -55...200 °C at ambient temperature 20 °C | Room temperature...450 °C at ambient temperature 20 °C | Room temperature...650 °C |
Dimension of the Calibration Insert | Ø 28 x 150 mm (calibration insert easily exchangeable) | Ø 60 x 150 mm (calibration insert easily exchangeable) | Ø 28 x 150 mm (calibration insert easily exchangeable) | Ø 60 x 150 mm (calibration insert easily exchangeable) | Ø 28 x 150 mm (calibration insert easily exchangeable) |
Dry Block |
|||||
Display Accuracy | ±0.2 °C | ±0.3 °C | ±0.4 °C | ||
Temperature Stability | ±0.05 °C | ||||
Resolution of the Temperature Display | 0.01 °C between -9.99...99.99 °C, else 0.1 °C | 0.01 °C in the range room temperature...99.99 °C, else 0.1 °C | |||
Reference Temperature Sensor | Internal, fixed installation | ||||
Interface | RS485 (calibrator) to USB (PC) | ||||
Connectivity | MODBUS | ||||
Dimensions |
|||||
→ Width | 210 mm | 150 mm | |||
→ Height | 380 + 50 mm (Handle) | 330 + 70 mm (Handle) | |||
→ Depth | 300 mm | 270 mm | |||
Weight | Approx. 10 kg | Approx. 7.5 kg | Approx. 12.5 kg | Approx. 7.5 kg | |
Power Supply | 100...240 VAC, 50 / 60 Hz | 230...240 VAC, 50 / 60 Hz | 100...240 VAC, 50 / 60 Hz | ||
Power Consumption | Approx. 375 W | Approx. 555 W | Approx. 2000 W | Approx. 1000 W | |
Display |
|||||
Display | 2-line, 4-digit digital display red / green, unit °C / °F | ||||
Approvals |
|||||
Reviews
SKU | TP 17 S |
---|