The Siglent SHS1102X Handheld Oscilloscope is a handheld, digital oscilloscope and 6000-count multimeter with a 100 MHz bandwidth, two isolated channels, a single ADC with a 1 GSa/s maximum sample rate, and a 12 Mpts memory. This robust, CAT II 1000V/ CAT III 600V- and IP51-rated digital oscilloscope and multimeter is ideal for service and support applications in the laboratory and the field.
Furthermore, complete isolation between the two oscilloscope channels, single multimeter channel, power adapter, and USB host/device port reduces the risk of accidental short circuits. As a result, the Siglent SHS1102X Handheld Oscilloscope is ideal for laboratory and floating signal measurements. The Siglent SHS1102X Handheld Oscilloscope’s portable design and long battery life combined with standard serial trigger and decoding (IIC, SPI, UART, CAN, LIN) make it suitable for use in the automotive and embedded industries.
The Siglent SHS1102X Handheld Oscilloscope is a portable, versatile, and reliable combined digital oscilloscope and multimeter.
Siglent SHS1102X Handheld Oscilloscope Key Features
- A handheld, digital oscilloscope and 6000-count multimeter
- Bandwidth: 100MHz
- Two isolated channels
- Single ADC with a 1 GSa/s maximum sample rate
- Two-channel sample rate: 500 MSa/s
- Waveform capture rate: 100 000 wfm/s (Normal mode)
- Waveform capture rate: 400 000 wfm/s (Sequence mode)
- Supports 256-level intensity grading and colour temperature
- 12 Mpts memory
- Digital trigger system
- Safety rating: CAT II 1000V/ CAT III 600V
- IP51
- Compliance with UL61010-1, UL61010-2-030, UL61010-2-033
- Full isolation reduces the risk of accidental short circuits
- Ideal for laboratory and floating signal measurements
- Portable design
- Long battery life
- UL2054 certified lithium battery pack, 6900 mAh capacity, external charger
- Standard serial trigger and decoding (IIC, SPI, UART, CAN, LIN)
- Intelligent trigger: Edge, Slope, Pulse Width, Window, Runt, Interval, Time Out (Dropout), Pattern
- Video trigger/HDTV
- Low background noise with voltage scales from 2 mV/div to 100 V/div
- 3 one-button shortcuts for Oscilloscope, Multimeter, and Recorder functions
- 8 one-button shortcuts for Run/Stop, Auto Setup, Default, Measure, Cursors, Display/Persists, Clear Sweep, and Print
- Segmented acquisition (Sequence) mode
- History Waveform Record (History) function
- Automatic Measurement function for 38 parameters
- Measurement Statistics function
- Zoom function
- Gating function
- Math function (FFT, addition, subtraction, multiplication, division, integration, differential square root)
- Reference function
- 1 Mpts FFT supports Peaks and Markers
- The Default key may be customised or left as factory/default
- Multi-language display
- Multi-language online help
- Security Erase mode
- Search and Navigation Function
- Recorder mode with Sample and Measurement Loggers
- True-RMS AC voltage/current measurement multiplier
- 5.6” TFT-LCD with 640x480px resolution
- Interface types: isolated USB host and USB device (MicroUSB – TMC)
- Supports SCPI remote control commands
- Ideal for service and support applications in the laboratory and the field
- Suitable for use in the automotive and embedded industries
- A portable, versatile, and reliable combined digital oscilloscope and multimeter
What’s Included?
- Siglent SHS1102X Handheld Oscilloscope – 100 MHz, 2 Isolated Channels
- 1x 6900 mAh Battery
- 2x PB925 250 MHz Oscilloscope Probe
- 2x Current Adapter (1x SCD600MA / 1x SCD10A)
- 1x Multimeter Probes Set
- 1x Power Adapter/Charger
- 1x USB Cable
- 1x Quick Start Guide
- Tolsen 7 Piece Insulated Precision Screwdriver Set - TS-9900006, typically £9.99
Siglent SHS800X/ SHS100X Handheld Oscilloscopes Technical Specifications
Model | SHS810X | SHS820X | SHS1102X | SHS1202X |
Bandwidth | 100 MHz | 200 MHz | 100 MHz | 200 MHz |
Sample rate (Max.) |
Two-channel share a single 1 GSa/s ADC. When two channels are enabled, each channel has a maximum sample rate of 500 MSa/s. When a single channel is active, that channel has a sample rate of 1 GSa/s |
|||
Channels | 2 analog oscilloscope channels, 1 multimeter channel | |||
Memory depth (Max.) |
6 Mpts/CH (dual-channel mode) 12 Mpts/CH (single channel mode) |
|||
Waveform capture rate (Max.) |
100,000 wfm/s (normal mode), 400,000 wfm/s (sequence mode) | |||
Trigger type | Edge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, Video | |||
Serial Trigger and decoder |
IIC, SPI, UART, CAN, LIN | |||
Data Logger(Recorder) |
Sample Logger. The Max sample rate is 25 kSa/s, the Min sample rate is 1 Sa/s | |||
Measurement Logger. The Max interval is 10 minutes, the Min interval is 0.1 seconds. The Max items of logging are 4 |
||||
I/O | USB Host, USB Device | |||
Max input Voltage (Scope) |
CAT II 300 Vrms Between BNC Signal and Protecting Earth CAT II 30 Vrms Between BNC GND and Protecting Earth CAT II 300 Vrms Between BNC Signal and BNC GND |
CAT III 600 Vrms, CAT II 1000 Vrms Between BNC Signal and Protecting Earth CAT III 600 Vrms, CAT II 1000 Vrms Between BNC GND and Protecting Earth CAT III 300 Vrms Between BNC Signal and BNC GND |
||
Max input Voltage (Meter) |
CAT III 300 Vrms, CAT II 600 Vrms | CAT III 600 Vrms, CAT II 1000 Vrms | ||
Probe | PP510 | PP215 | PB925 | |
Display | 5.6-inch TFT-LCD (640x480) | |||
Weight | Without package 1.75 kg. With package 3.5 kg |
Reviews
SKU | SHS1102X |
---|---|
Manufacturer Part Code | SHS1102X |