The SHN900A series is a highly integrated portable vector network analyser with a frequency range of up to 26.5 GHz. It combines vector network analysis, time domain analysis, spectrum analysis, and standard cable and antenna testing in a single, compact device. It is ideal for testing RF components, cables, and systems in applications.
The SHN900A operates on a Li-ion battery and can run for up to 4 hours. It is a full 2-port vector network analyser with advanced TDR measurements, pulse testing, pass-fail limit checks, and complete S-parameter analysis.
Accurate RF testing is possible with the 110 dB and low trace noise. It supports various measurements, including scattering parameters, VSWR, port matching, insertion loss, tower amplifier debugging, cable fault location, and troubleshooting through the CAT mode.
For interference analysis, the SHN900A models feature a built-in GPS function for pinpointing interference sources. Log and analyze spectrum, channel power, and adjacent channel power ratio at multiple locations.
SHN914A | SHN920 | SHN926A | |
---|---|---|---|
Frequency Range | 30 kHz-14 GHz | 30 kHz-20 GHz | 30 kHz-26.5 GHz |
Ports | 2 | ||
Frequency Resolution | 1 Hz | ||
Level Resolution | 0.05 dB | ||
Range of IFBW | 10 Hz~3 MHz | ||
Setting Range of Output Level | -45 dBm ~ +10 dBm | ||
Dynamic Range | 110 dB (Typ.) | ||
Types of Calibration | Response calibration, Enhanced Response calibration, Full-one port calibration, Full-two port calibration, TRL calibration | ||
Types of Measurement | Scattering-parameter measurement, differential-parameter measurement, receiver measurement, time-domain parameter analysis, limit test, ripple test, impedance conversion, fixture simulation, adapter removal/insertion, enhanced time-domain parameter analysis (TDR), spectrum analysis, frequency offset, scalar mixer measurement, pulse measurement | ||
Bias-Tees | Support | ||
Interface | LAN, USB Device, USB Host(USB-GPIB) | ||
Remote Control | SCPI/ Labview/ IVI based on USB-TMC/ VXI-11/ Socket/ Telnet/ WebServer | ||
Display | 8.4-inch touch screen | ||
GPS | Support | ||
Operating Environment | |||
Temperature | 0 to 50 ℃ | ||
Humidity | 20% to 80% at wet bulb temperature < +29 °C (non-condensation) | ||
Altitude | 0 to 3000 m | ||
Non-Operating Storage Environment | |||
Temperature | -20 ℃ to 70 ℃ | ||
Humidity | 20% to 90% at wet bulb temperature < +40 °C (non-condensation) | ||
Altitude | 0 to 15000 m | ||
Size | W×H×D=310 mm × 215 mm × 78.5 mm | ||
Weight | 3.2 kg | ||
EMC | |||
Conducted Disturbance: CISPR 11/EN 55011 | CLASS A group 1, 150 kHz - 30 MHz | ||
Radiated Disturbance: CISPR 11/EN 55011 | CLASS A group 1, 30 MHz - 1 GHz | ||
Electrostatic Discharge(ESD): IEC61000-4-2/EN61000-4-2 | 4.0 kV (contact), 8.0 kV (air) | ||
Radio-Frequency Electromagnetic Field Immunity: IEC 61000-4-3/EN 61000-4-3 | 10 V/m (80 MHz to 1 GHz) 3 V/m (1.4 GHz to 2 GHz) 1 V/m (2.0 GHz to 2.7 GHz) |
||
Electrical Fast Transients (EFT): IEC 61000-4-4/EN 61000-4-4 | 2 kV (AC power ports) | ||
Surges: IEC 61000-4-5/EN 61000-4-5 | 1 kV (Line to line) 2 kV (Line to ground) |
||
Radio-Frequency Continuous Conducted Immunity: IEC 61000-4-6/EN 61000-4-6 | 3 V, 0.15-80 MHz | ||
Voltage dips and interruptions: IEC 61000-4-11/EN 61000-4-11 | Voltage dips 0% UT during 1 cycle 40% UT during 10/12 cycles 70% UT during 25/30 cycles Voltage interruptions: 0% UT during 250 cycles |
||
Safety | UL 61010-1:2012/R: 2018-11; CAN/CSA-C22.2 No. 61010-1:2012/A1:2018-11. UL 61010-2-030:2018; CAN/CSA-C22.2 No. 61010-2-030:2018. |