The professional PAT testing kit for professional PAT testers - Seaward's PrimeTest 250+ Pro Bundle gives you absolutely everything you'll need for both PAT testing and managing your labels and records.
These items are included as standard with the PrimeTest 250 Plus:
The Pro bundle also comes with:
The upgraded version of Seaward's PrimeTest 250, the 250 Plus includes built-in memory storage and direct download to PC capabilities.
Up to 999 individual PAT records can be directly stored on the PT250+'s memory at the push of a button, then transferred to PC via USB connection. A free datalogging utility is included for easy transfer (records are also transferred in CSV format and can be easily opened in Excel).
The PrimeTest 250+ carries out absolutely all PAT testing procedures required by the IET Code of Practice to ensure the safety of electrical appliances.
Earth Continuity | |
Output Current |
200mA minimum into 2Ω |
Test Voltage (o/c) | 9V DC nominal |
Test Duration (Class I Test) | 2s nominal |
Display Range | 0.01Ω to 19.99Ω |
Pass Value (Class I Test) | 0.2Ω |
Insulation Resistance | |
Test Voltage | 250/500V DC @1mA nominal, <2mA (s/c) |
Test Duration (Class I or II) | 2s |
Display Range | 0.01MΩ to 19.99MΩ |
Pass Value | Class I: 1.0MΩ Class II: 2.0MΩ |
Equivalent Leakage | |
Test Voltage | 40V Nominal AC 50Hz Open Circuit |
Test Duration | 2s |
Display Range | 0.1mA to 19.99mA |
Pass Value | 0.75mA/3.5mA (user selectable with 0.75mA as default)/0.25mA CL II |
IEC Lead Test | |
Test Voltage | 5V DC Nominal |
Test Duration | Time for Test (2s max) |
Test | Live/Neutral Checks for o/c, s/c and crossed |
Protective Conductor Current | |
Test Voltage | Supply voltage, max current 13A |
Test Duration | 120s Maximum |
Display Range | 0.15mA to 9.99mA |
Pass Value | 0.75mA/3.5mA (user selectable with 0.75mA as default) |
Touch Current | |
Test Voltage | Supply voltage, max current 13A |
Test Duration | 120s maximum |
Display Range | 0.10mA to 3.50mA |
Pass Value | 0.25mA |
3 Phase Differential Leakage Current *Requires 3 phase adaptor accessory |
|
Test Voltage | 3 phase supply voltage |
Test Duration | Continuous measurements |
Display Range | 0.10mA to 9.99mA |
Pass Value | 0.75mA/3.5mA (user selectable with 0.75mA as default) |
RCD Trip Time | |
Test Voltage | Mains supply voltage |
Test Current | 30mA/150mA rms sinusoidal |
Test Current Phase | 0/180° auto switched on alternate tests |
Measuring Range | 0ms to 500ms |
Pass Value | 200ms |
Power Socket Check | |
Input Voltage Range | 225-254V AC max current 13A UK |
Indicates configuration of voltage potential: | Line to earth, line to neutral, neutral to earth |
General | |
Memory Size | 999 Test Records |
Power Source | 6 x AA Batteries |