Test the accuracy of PAT testers, installation (multifunction) testers, earth bond testers, earth continuity testers and RCD testers with Seaward's comprehensive calibration checkbox!
Ideal for use in the time period between official calibration by a certified laboratory, this checkbox tests the ongoing accuracy of all common parameters associated with the instrument under test. It can be used to quickly and fully test earth continuity, insulation resistance, RCD trip time, RCD trip current, Loop, PE conductor current, touch current and can also perform flash testing.
When testing RCDs you can relax as the Powercheck 1557 is designed not to trip RCDs. It can also be used to test earth bond/continuity testers to 25A and comes built into its own protective, robust hard carrying case to ensure protection of the instrument in absolutely any environment.
The Powercheck 1557 is also compliant with NICEIC and NAPIT standards and has been certified as testing in line with BS 7671, BS EN 61557 and the IET Code of Practice.
The PowerCheck 1557 Tests:
- Full Earth Continuity
- Insulation Resistance
- RCD Trip Time
- RCD Trip Current
- Loop
- PE Conductor Current
- Touch Current
- Flash test verification
Features
- IEE Code of Practice compliant
- Tests to BS 7671/EN 61557
- The most comprehensive range of tests available
- Confirm performance between calibrations
- Rugged and robust
- Does not trip RCDs
- Compatible with all tester brands
Seaward Powercheck 1557 Technical Specifications
INSTALLATION TEST INSTRUMENTS | |
Earth Continuity Verification | |
Test Current | In > 200mA Indication |
Test Voltage | 4V < UN > 24V Indication |
Test Resistance | 0.5Ω and 2Ω |
Insulation Resistance Verification | |
Open Circuit Test Voltage | 250V < UN < 375V Indication 500V < UN < 750V Indication 1000V < UN < 1500 Indication |
Test Current | IN > 1mA into 1000Ω/V |
Max Test Current | Ik < 2mA |
Test Resistances | 0.25MΩ, 0.5MΩ, 1.0MΩ |
Earth Loop Verification | |
Test Values | Loop, Loop + 1Ω, Loop + 180Ω |
RCD Verification | |
Trip Current | 10mA, 30mA, 100mA |
Trip Times | 20ms, 40ms, 500ms |
Test Current Multiplier | 1/2Δn, lΔn and 5 IΔn Verification |
Voltage Verification | |
Test Voltage | 240V AC RMS test output |
PAT FUNCTIONS | |
Earth Continuity Verification | |
Test Resistances | 0.2Ω and 2Ω |
Insulation Resistance Verification | |
Test Resistances | 500kΩ, 1MΩ and 2MΩ |
PE Conductor Current | |
Test Currents | 0.1mA, 0.25mA and 0.5mA |
Flash Test Current | |
Test Currents | 0.5mA, 1mA, 1.5mA |