Optimise your production line safety testing with Seaward Clare's HAL103, a powerful, multifunctional hipot tester made for checking the safety of electrical and electronic items.
This is the upgraded version of Seaward's HAL102; the main difference between the two is the HAL103 also includes an earth/ground bond testing mode. It can also perform AC and DC flash/hipot tests, checks DC insulation resistance and also has an ARC detection mode.
Seaward HAL safety testers are made with speed and convenience in mind; the HAL103 includes a wide range of different tests and functionality, allowing you to perform everything from fully configurable manual testing to high volume automated testing. You can choose between three modes on the HAL103 - automatic mode will automatically cycle through tests on connected equipment, manual mode gives you full control and the PC mode allows you to control the unit remotely using a compatible PC or laptop (requires E-Base software package, sold separately).
Once you're done testing, all data is seamlessly saved into the HAL103's 6000 record non-volatile memory. Product details, the user, location, site and the date/time can all be stored, with the ability to send all data into the optional software package for further analysis once testing is completed.
There's much more to this tester too; the HAL103 includes a large-size, graphical LCD display, starts up fast and has fully isolated test outputs in compliance with EN50191.
The HAL103 has a wide range of optional accessories available - please see below.
There are multiple models in the Seaward HAL series. This comparison chart shows the difference between each.
Features | HAL101 | HAL102 | HAL103 | HAL104 | HAL LED |
---|---|---|---|---|---|
Earth/Ground Bond | - | - | √ | √ | √ |
AC Flash/Hipot | √ | √ | √ | √ | √ |
DC Flash/Hipot | √ | √ | √ | √ | √ |
DC Insulation Resistance | √ | √ | √ | √ | √ |
ARC Detection | √ | √ | √ | √ | √ |
Leakage | - | - | - | √ | √ |
Load Power | - | - | - | √ | - |
Load Power (200mVA resolution) | - | - | - | - | √ |
Power Factor | - | - | - | √ | √ |
Results Memory | √ | √ | √ | √ | √ |
Automation Option | √ | √ | √ | √ | √ |
Barcode Scanner/Printer Option | √ | √ | √ | √ | √ |
Internal Scanner | - | √ | - | - | - |
Earth Ground/Bond Test | |
---|---|
Test Voltage | 6V AC (nominal) |
Frequency | 50 or 60Hz (independent of supply) |
Display Range and Accuracy | 0 to 1500mΩ - ±2% ±5 counts |
Display Resolution | 1mΩ |
Compliance Test Ranges | |
Current/Load Resistance/Time | 5A, 1000mΩ - continuous 10A, 500mΩ - continuous 25A, 200mΩ - continuous 30A, 150mΩ - 60 seconds 40A, 100mΩ - 60 seconds |
Settable Output Current Range | 0.1 to 40.0A |
Selectable Range of PASS/FAIL Levels | 0 to 1500mΩ |
Insulation Resistance Test | |
DC Output Voltage | 0.10kV to 6.00kV (10V/step when manually adjusted) (50V/step in test sequence program) |
Display Range | 0.01MΩ to 500MΩ |
Display Range/Accuracy | 0.03MΩ to 350MΩ: ±5% ± 5 counts 350MΩ to 500MΩ: indication only |
Display Resolution | 0.01MΩ |
PASS/FAIL Level | 0.00MΩ to 500.0MΩ |
AC Dielectric Strength Test | |
Programmable Voltage Range | 0.10 to 5.00kV (10Vstep when manually adjusted) 50V/step in test sequence program) |
Frequency (Independent of Supply) | 50 or 60Hz |
Voltage Display Range/Accuracy | 0.10kV to 5.00kV: ±1% ±5 counts |
Voltage Display Resolution | 0.01kV |
Current Display Range/Accuracy | 0.01mA to 20.00mA: ±1% ± 5 counts |
Current Display Resolution | 0.01mA |
Selectable Range of PASS/FAIL Levels | 0.01mA to 20.00mA |
Maximum Current Output | 20.00mA @ 5kV |
Optional Arc Detection | 9 levels |
DC Dielectric Strength Test | |
Programmable Voltage Range | 0.10 to 6.00kV (10V/step when manually adjusted) (50V/step in test sequence program) |
Voltage Display Range and Accuracy | 0.10 to 6.00kV: ±1% ±5 counts |
Voltage Display Resolution | 0.01kV |
Current Display Range and Accuracy | 0.01mA to 10.00mA: ±1% ±5 counts |
Current Display Resolution | 0.01mA |
Selectable Range of PASS/FAIL Levels | 0.01mA to 10.00mA |
Maximum Current Output | 10.00mA |
Optional Arc Detection | 9 levels |
Leakage Current Measurement | |
Display Range and Accuracy | 0.10mA to 20.00mA ±1% ±5 counts |
Display Resolution | 0.01mA |
Selectable Range of PASS/FAIL Levels | 0.01mA to 20mA |
Touch Current Measurement | |
Display Range and Accuracy | 0.02mA to 5.00mA ±1% ±5 counts |
Display Resolution | 0.01mA |
Selectable Range of PASS/FAIL Levels | 0.02mA to 5.00mA |
Measuring Device | IEC/EN 60990 Fig 4 IEC/EN 60990 Fig 3 or Fig 5 on request |
General Specifications | |
Case Dimensions | 200 x 300 x 370mm (W x H x D) |
Weight | 15kf approx |
Operating Voltage Range | Selectable: 115 to 230V AC RMS, 50/60Hz |
EN50191 | Compliant when used with appropriate accessories |