All Seaward Products

Seaward Clare HAL103 AC/DC Hipot, Insulation, Ground/Earth Bond Tester

SKU
H103
Rating:
0%
(0)
Reward Points
:
5299
£6,358.80 £5,299.00
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Seaward Clare HAL103 AC/DC Hipot, Insulation & Ground/Earth Bond Tester

Optimise your production line safety testing with Seaward Clare's HAL103, a powerful, multifunctional hipot tester made for checking the safety of electrical and electronic items.

This is the upgraded version of Seaward's HAL102; the main difference between the two is the HAL103 also includes an earth/ground bond testing mode. It can also perform AC and DC flash/hipot tests, checks DC insulation resistance and also has an ARC detection mode.

Seaward HAL safety testers are made with speed and convenience in mind; the HAL103 includes a wide range of different tests and functionality, allowing you to perform everything from fully configurable manual testing to high volume automated testing. You can choose between three modes on the HAL103 - automatic mode will automatically cycle through tests on connected equipment, manual mode gives you full control and the PC mode allows you to control the unit remotely using a compatible PC or laptop (requires E-Base software package, sold separately).

HAL Series Production Line Safety Testers

Once you're done testing, all data is seamlessly saved into the HAL103's 6000 record non-volatile memory. Product details, the user, location, site and the date/time can all be stored, with the ability to send all data into the optional software package for further analysis once testing is completed.

There's much more to this tester too; the HAL103 includes a large-size, graphical LCD display, starts up fast and has fully isolated test outputs in compliance with EN50191.

Seaward Clare HAL103 AC/DC Hipot, Insulation & Ground/Earth Bond Tester Key Features

  • Upgraded version of the Seaward HAL102
  • Insulation resistance test with variable DC output voltage from 0.10kV to 6.00kV
  • AC/DC dielectric strength testing with programmable voltage range from 0.10kV to 5.00kV (AC)/ 6.00kV (DC)
  • Multiple channel output (5 isolated pairs of output terminals)
  • Store up to 6000 test results in non-voltatile flash memory - includes space for information on product, user, location, site, date and time
  • Highly accurate leakage and DCIR measurements
  • Large-size, full graphical display with real-time clock
  • Connects to a PC, barcode scanner and printer (requires software for use on PC - printers/barcode scanners sold separately)
  • Seamlessly works with Seaward's optional Safety e-Base software for full PC control
  • Automatic test code generation
  • Fast startup
  • Fully isolated test ouputs in compliance with EN50191
  • Fully automatic and manually settable testing programmes
  • 4 wire ground bond test measurements

What's Included?

  • Seaward Clare HAL103 Tester
  • Instruction Manual
  • Power Cord
  • Guard Plug
  • Comms Cable
  • Test Probes/Clips

Optional Accessories

The HAL103 has a wide range of optional accessories available - please see below.

  • 194A922 - CCD Barcode Scanner
  • Clare Safety e-Base Pro Software
  • H-5009 - Class I Output Socket Box
  • H-5014 - Data Cable
  • Desk Test n Tag Printer
  • H-5030 - Desk Test n Tag Printer Lead
  • 01521/1 - Earth Test Clip
  • 01520/1 - Earth Test Probe
  • Y160H - Fault Simulator
  • Guard Plug with Link
  • H-5003 - Hipot Test Clip (Black)
  • H-5003/R - Hipot Test Clip (Red)
  • 03918/2 - Hipot Test Probe (Red)
  • Y160 Fault Simulator 
  • 483A910 - PowerSmart Module - increases single-phase load testing, current up to 50A
  • Status Beacon

Seaward HAL Series Comparison Chart

There are multiple models in the Seaward HAL series. This comparison chart shows the difference between each.

Features HAL101 HAL102 HAL103 HAL104 HAL LED
Earth/Ground Bond - -
AC Flash/Hipot
DC Flash/Hipot
DC Insulation Resistance
ARC Detection
Leakage - - -
Load Power - - - -
Load Power (200mVA resolution) - - - -
Power Factor - - -
Results Memory
Automation Option
Barcode Scanner/Printer Option
Internal Scanner - - - -

Seaward Clare HAL103 Technical Specifications

Earth Ground/Bond Test
Test Voltage 6V AC (nominal)
Frequency 50 or 60Hz (independent of supply)
Display Range and Accuracy 0 to 1500mΩ - ±2% ±5 counts
Display Resolution 1mΩ
Compliance Test Ranges  
Current/Load Resistance/Time 5A, 1000mΩ - continuous
10A, 500mΩ - continuous
25A, 200mΩ - continuous
30A, 150mΩ - 60 seconds
40A, 100mΩ - 60 seconds
Settable Output Current Range 0.1 to 40.0A
Selectable Range of PASS/FAIL Levels 0 to 1500mΩ
Insulation Resistance Test
DC Output Voltage 0.10kV to 6.00kV
(10V/step when manually adjusted)
(50V/step in test sequence program)
Display Range 0.01MΩ to 500MΩ
Display Range/Accuracy 0.03MΩ to 350MΩ: ±5% ± 5 counts
350MΩ to 500MΩ: indication only
Display Resolution 0.01MΩ
PASS/FAIL Level 0.00MΩ to 500.0MΩ
AC Dielectric Strength Test
Programmable Voltage Range 0.10 to 5.00kV
(10Vstep when manually adjusted)
50V/step in test sequence program)
Frequency (Independent of Supply) 50 or 60Hz
Voltage Display Range/Accuracy 0.10kV to 5.00kV: ±1% ±5 counts
Voltage Display Resolution 0.01kV
Current Display Range/Accuracy 0.01mA to 20.00mA: ±1% ± 5 counts
Current Display Resolution 0.01mA
Selectable Range of PASS/FAIL Levels 0.01mA to 20.00mA
Maximum Current Output 20.00mA @ 5kV
Optional Arc Detection 9 levels
DC Dielectric Strength Test
Programmable Voltage Range 0.10 to 6.00kV
(10V/step when manually adjusted)
(50V/step in test sequence program)
Voltage Display Range and Accuracy 0.10 to 6.00kV: ±1% ±5 counts
Voltage Display Resolution 0.01kV
Current Display Range and Accuracy 0.01mA to 10.00mA: ±1% ±5 counts
Current Display Resolution 0.01mA
Selectable Range of PASS/FAIL Levels 0.01mA to 10.00mA
Maximum Current Output 10.00mA
Optional Arc Detection 9 levels
Leakage Current Measurement
Display Range and Accuracy 0.10mA to 20.00mA ±1% ±5 counts
Display Resolution 0.01mA
Selectable Range of PASS/FAIL Levels 0.01mA to 20mA
Touch Current Measurement
Display Range and Accuracy 0.02mA to 5.00mA ±1% ±5 counts
Display Resolution 0.01mA
Selectable Range of PASS/FAIL Levels 0.02mA to 5.00mA
Measuring Device IEC/EN 60990 Fig 4
IEC/EN 60990 Fig 3 or Fig 5 on request
General Specifications
Case Dimensions 200 x 300 x 370mm (W x H x D)
Weight 15kf approx
Operating Voltage Range Selectable: 115 to 230V AC RMS, 50/60Hz
EN50191 Compliant when used with appropriate accessories
Accessories related to this product:
Seaward Clare HAL103 Hipot Tester - Datasheet Datasheets Seaward Clare HAL103 Hipot Tester - User Manual Manuals & Guides

Reviews

Additional Information
SKU H103
Manufacturer Part Code H103