The Seaward Clare HAL LED model is a production line safety tester with reduced power measurement range and greater resolution than the HAL104 and is designed to be used on low power electronics such as LED lights and other luminaires.
This multifunctional safety tester includes a huge range of electrical safety testing procedures - it can perform earth/ground bond, AC/DC flash/hipot, DC insulation resistance, leakage, load power (200mVA resolution for low power electronics) and also has ARC detection and power factor modes.
With Seaward HAL units, production line safety testing is made simple. You can set up a comprehensive automatic testing sequence to automate your safety tests, with all results stored in the tester's internal memory, or you can instead take full control over testing procedures with the manual mode. By connecting the HAL LED to a PC you can control the unit remotely (requires optional e-Base software package), transfer results and perform further analysis after testing is completed.
Every HAL unit includes internal memory storage, with space for up to 6000 records. You can store results alongside details of the product, the user who performed the test, the product's location, the site you were working at and even store date/time stamps so you know exactly when everything was done.
Additional features of this tester include a large size, full graphical display, 4 wire earth ground bond measurements, the ability to connect to optional printers/barcode scanners and it also starts up fast to ensure you can get more done.
The outputs of the HAL LED are fully isolated in compliance with EN50191.
*Please note that this software package is sold separately
Take complete control over your HAL104 with Safety e-Base software for your PC.
With this software, you'll be able to create totally customisable test sequences which can be fully operated via a PC from a safe, convenient location, even if that's away from the production line.
A customisable user interface allows you to provide user prompts with texts and pictures (ideal for training new operators) and you can be guided step-by-step through the testing process, reducing human error and ensuring higher levels of productivity.
e-Base also has the added benefit of totally traceable results with virtually unlimited storage on your PC or network drive.
Features include:
As mentioned above the Seaward HAL LED Tester can be controlled remotely via the user's PC, enabling automated operation. It can also communicate with a PLC (programmable logic controller) and supports the following advanced integration options:
In addition to this, Seaward offers a number of smart modules, accessories, and consumables designed to improve the functionality of the HAL Tester, as well as the productivity and traceability of production line testing regimes. Moreover, Seaward's enclosures, beacons, and hand switches can be used to ensure compliance with the EN50191 standard for the safe erection and operation of electrical enclosures.
The HAL LED has a wide range of optional accessories available - please see below.
There are multiple models in the Seaward HAL series. This comparison chart shows the difference between each.
Features | HAL101 | HAL102 | HAL103 | HAL104 | HAL LED |
---|---|---|---|---|---|
Earth/Ground Bond | - | - | √ | √ | √ |
AC Flash/Hipot | √ | √ | √ | √ | √ |
DC Flash/Hipot | √ | √ | √ | √ | √ |
DC Insulation Resistance | √ | √ | √ | √ | √ |
ARC Detection | √ | √ | √ | √ | √ |
Leakage | - | - | - | √ | √ |
Load Power | - | - | - | √ | - |
Load Power (200mVA resolution) | - | - | - | - | √ |
Power Factor | - | - | - | √ | √ |
Results Memory | √ | √ | √ | √ | √ |
Automation Option | √ | √ | √ | √ | √ |
Barcode Scanner/Printer Option | √ | √ | √ | √ | √ |
Internal Scanner | - | √ | - | - | - |
Earth Ground/Bond Test | |
---|---|
Test Voltage | 6V AC (nominal) |
Frequency | 50 or 60Hz (independent of supply) |
Display Range and Accuracy | 0 to 1500mΩ - ±2% ±5 counts |
Display Resolution | 1mΩ |
Compliance Test Ranges | |
Current/Load Resistance/Time | 5A, 1000mΩ - continuous 10A, 500mΩ - continuous 25A, 200mΩ - continuous 30A, 150mΩ - 60 seconds 40A, 100mΩ - 60 seconds |
Settable Output Current Range | 0.1 to 40.0A |
Selectable Range of PASS/FAIL Levels | 0 to 1500mΩ |
Insulation Resistance Test | |
DC Output Voltage | 0.10kV to 6.00kV (10V/step when manually adjusted) (50V/step in test sequence program) |
Display Range | 0.01MΩ to 500MΩ |
Display Range/Accuracy | 0.03MΩ to 350MΩ: ±5% ± 5 counts 350MΩ to 500MΩ: indication only |
Display Resolution | 0.01MΩ |
PASS/FAIL Level | 0.00MΩ to 500.0MΩ |
AC Dielectric Strength Test | |
Programmable Voltage Range | 0.10 to 5.00kV (10Vstep when manually adjusted) 50V/step in test sequence program) |
Frequency (Independent of Supply) | 50 or 60Hz |
Voltage Display Range/Accuracy | 0.10kV to 5.00kV: ±1% ±5 counts |
Voltage Display Resolution | 0.01kV |
Current Display Range/Accuracy | 0.01mA to 20.00mA: ±1% ± 5 counts |
Current Display Resolution | 0.01mA |
Selectable Range of PASS/FAIL Levels | 0.01mA to 20.00mA |
Maximum Current Output | 20.00mA @ 5kV |
Optional Arc Detection | 9 levels |
DC Dielectric Strength Test | |
Programmable Voltage Range | 0.10 to 6.00kV (10V/step when manually adjusted) (50V/step in test sequence program) |
Voltage Display Range and Accuracy | 0.10 to 6.00kV: ±1% ±5 counts |
Voltage Display Resolution | 0.01kV |
Current Display Range and Accuracy | 0.01mA to 10.00mA: ±1% ±5 counts |
Current Display Resolution | 0.01mA |
Selectable Range of PASS/FAIL Levels | 0.01mA to 10.00mA |
Maximum Current Output | 10.00mA |
Optional Arc Detection | 9 levels |
Power and Leakage Test | |
Test Voltage | 110V to 230V AC 20A nominal (Vin-Vout) |
Maximum Power Output | Up to 5.0kVA (dependent on mains supply rating) |
Output Power Measurement | |
Measurement type | Single phase |
Display Range and Accuracy | 000.0 to 999.9VA 000.2 to 1000VA (±5% ±2 digits) |
Selectable Range of PASS/FAIl Levels | 0.002 to 1000VA |
Single Phase Power Factor Measurement | |
Display Range | 0.000 to 1.000 |
Selectable Range of PASS/FAIL Levels | 0.000 to 1.000 |
Leakage Current Measurement | |
Display Range and Accuracy | 0.10mA to 20.00mA ±1% ±5 counts |
Display Resolution | 0.01mA |
Selectable Range of PASS/FAIL Levels | 0.01mA to 20mA |
Touch Current Measurement | |
Display Range and Accuracy | 0.02mA to 5.00mA ±1% ±5 counts |
Display Resolution | 0.01mA |
Selectable Range of PASS/FAIL Levels | 0.02mA to 5.00mA |
Measuring Device | IEC/EN 60990 Fig 4 IEC/EN 60990 Fig 3 or Fig 5 on request |
General Specifications | |
Case Dimensions | 200 x 300 x 370mm (W x H x D) |
Weight | 15kf approx |
Operating Voltage Range | Selectable: 115 to 230V AC RMS, 50/60Hz |
EN50191 | Compliant when used with appropriate accessories |