The Seaward Apollo 600+ 5th Edition PAT Tester is designed to revolutionise PAT Testing with built-in safety management, risk assessment and a comprehensive range of electrical safety tests to offer the user an all in one solution to managing, assessing and testing in any environment. The new 5th Edition update ensures you are compliant with the latest 5th Edition code of practice, with the addition of Class 2 FE and protective and touch leakage limits to 5mA.
The 600+ features an onboard full-colour camera with flash, allowing photographs to be taken and stored (up to 2,000) on the unit itself, as well as 50,000 appliance records for complete traceability. Results can be directly transferred to an android device or straight to a flash drive, (unique to the 600+) The Apollo 600+ also caters for those who run health and safety inspections and provides onboard reports for fire detection and emergency lighting, the ultimate tool for larger business, caretakers and those who perform PAT Testing on a large scale.
The Apollo 600+ benefits from advanced features to the user interface that have been implemented based on user feedback, meaning the PAT Tester has been specifically engineered to suit user needs. The tester is supplied with an additional wiring harness and a removable, rechargeable battery, meaning high volume PAT testing needn't be a problem, just exchange the battery pack and carry on testing!
The QR code system allows more data to be stored in your PAT label barcode including; Asset ID, site, location, last and next test dates. The codes are printed directly onto the label using the Test n Tag Elite 2 printer (sold separately) and when a retest is needed, can be scanned in again using the new Bluetooth 2D Elite barcode scanner (sold separately) and populate the fields automatically for quicker retesting.
The Apollo 600+ allows the battery to be externally charged making your job easier. With a new processor, testing is now faster and more efficient than ever before, the Wi-fi Hotspot feature means it has never been easier to get results back to your office via your mobile device.
Features designed to make testing quicker and more effective:
The new 5th Edition firmware will also be available to download free of charge for older Apollo users who will be able to update to the new firmware and benefit from the new test features.
Discover the ultimate PAT testing software, PATGuard 3, featuring comprehensive health and safety reporting. With fast record management, the ability to record workplace tests and inspections, automatic test scheduling, and the option to create client invoices and reports, Upload equipment details from your existing database, saving time on data entry in the field. PATGuard 3 is the optimal choice for your portable appliance testing needs. (Software sold separately).
Product Overview
Test leads now feature a stronger PVC insulation and sturdier probes for more demanding usage.
Which Seaward Apollo PAT Tester is right for you? See the differences between testing capabilities below.
General Features | Seaward Apollo 400+ | Seaward Apollo 500+ | Seaward Apollo 600+ |
---|---|---|---|
5th Edition Compliant | ✔ | ✔ | ✔ |
BSEN 50699 Compliant | ✔ | ✔ | ✔ |
Battery & mains powered | ✔ | ✔ | ✔ |
Colour Screen & QWERTY keypad | ✔ | ✔ | ✔ |
Large internal memory | 2000 records | 10,000 records | 50,000 records + 2000 images |
Bluetooth Scanner & printer compatible | ✔ | ✔ | ✔ |
Password controlled user accounts | - | ✔ | ✔ |
Set up multiple users with varying levels of privileges | - | ✔ | ✔ |
Clone facility to set up multiple testers | - | ✔ | ✔ |
Checkbox supplied as standard | - | ✔ | ✔ |
Test Inspection Features | Seaward Apollo 400+ | Seaward Apollo 500+ | Seaward Apollo 600+ |
Enter asset description after test using keypad or barcode scanner | ✔ | ✔ | ✔ |
Comprehensive electrical safety test features | ✔ | ✔ | ✔ |
Point to point measurement (Rpe & IR) | (Optional Accessory Required) | ✔ | ✔ |
User configurable electrical test/visual inspection sequences | 25 | 100 | 100 |
User set sites & locations | 50 | 50 | 100 |
Auto-increment asset ID | - | ✔ | ✔ |
PAT setup option to allow for custom menus | - | ✔ | ✔ |
Risk based retest period calculator | - | ✔ | ✔ |
User definable comments lines against test records | - | 4 | 4 |
Configurable checklists for any workplace test or inspection (user tests) | - | ✔ | ✔ |
On-board camera | - | - | ✔ |
Universal risk assessment | - | - | ✔ |
Health & safety certificates | - | - | ✔ |
Data Transfer Features | Seaward Apollo 400+ | Seaward Apollo 500+ | Seaward Apollo 600+ |
1D & 2D scanner connectivity | Reads 1D data only | ✔ | ✔ |
Bluetooth connectivity | ✔ | ✔ | ✔ |
Remote data transfer via mobile device | (Android Only) | (Android Only) | (Android & iOS) |
Download to PC via USB cable | ✔ | ✔ | ✔ |
Filter results to be downloaded | ✔ | ✔ | ✔ |
Select various label formats to print | 6 | 6 | 6 |
Print pass & fail labels with 1D barcode | ✔ | ✔ | ✔ |
Print pass & fail labels with 2D barcode | - | ✔ | ✔ |
Read 2D barcode labels with 2D scanner | - | ✔ | ✔ |
Add your company logo to labels (large 1D labels only) | - | ✔ | ✔ |
Upload previous results to tester for retest | - | ✔ | ✔ |
RFID reader connectivity | - | - | ✔ |
Data transfer via USB flash drive | - | - | ✔ |
Earth Continuity | |
Test Current | ±200mA DC |
Display Range | 0.01 to 19.99Ω |
Pass Value | User defined |
Insulation Resistance | |
Test Voltage | 500V / 250V DC @ 1mA nominal |
Display Range | 0.01MΩ to 19.99MΩ |
Pass Value | User defined |
IEC Lead Test | |
Test Voltage | 5V AC nominal |
Test | Live/neutral checks for o/c, s/c and crossed |
Protective Conductor Current/Load | |
Test Voltage | Supply voltage, maximum load current 16A |
Display Range | 0.01mA to 19.99mA |
Pass Value | User defined |
Touch Current | |
Test Voltage | Supply voltage, maximum load current 16A |
Display Range | 0.00 to 5mA |
Pass Value | User defined |
Load Power/Current | |
Test Voltage | 230V + 10%, maximum load current 16A |
Test Duration | Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads |
Display Range | 0.00kVA to 4.00kVA 0.00A to 16.00A |
Alternative Leakage Current | |
Test Voltages | >25V AC <50V AC |
Display Range | 0.00mA to 19.99mA |
Pass Value | User defined |
RCD Test | |
Test Voltage | 230V + 10%, -15% |
Test Current | 15mA/30mA rms sinusoidal |
Display Range | 0ms to 2000ms |
Test Method | Internal isolation to avoid tripping distribution board RCDs |
Power Socket Test | |
Voltage Range | 207V to 253V AC |
Indication of Voltage Potential | Line potential phase to earth Line potential phase to neutral Line potential neutral to earth |
General Specifications | |
Memory Size | 50000 records + 2000 photos |
Weight | 1.5kg |
Dimensions | 230 x 150mm x 100mm |
Power Source | Mains or rechargeable battery pack |
General Features | 600+ | 500+ | 400+ |
Battery & mains powered | • | • | • |
Colour screen & QWERTY keypad | • | • | • |
Large internal memory | up to 50,000 records and 2,000 photos | up to 10,000 records | up to 2,000 records |
Bluetooth scanner & printer compatible | • | • | • |
Password controlled user accounts | • | • | |
Set up multiple user accounts with varying levels of privileges | • | • | |
Clone facility to set up multiple testers | • | • | |
Checkbox supplied as standard | • | • | |
Test Inspection Features | 600+ | 500+ | 400+ |
Auto-increment asset ID | • | • | |
PAT Setup option to allow for custom menus | • | • | |
Enter asset description after test using the keypad or barcode scanner | • | • | • |
Comprehensive electrical safety test features | • | • | • |
Point to point measurement (Rpe & IR) | • | • | Optional accessory required |
User configurable electrical test/visual inspection sequences | 100 | 100 | 25 |
User set sites & locations | 100 | 100 | 50 |
Risk-based retest period calculator | • | • | |
User definable comments lines against test records | 4 | 4 | |
Configurable checklists for any workplace test or inspection (user tests) | • | • | |
Onboard camera | • | ||
Universal risk assessment | • | ||
Health & safety certificates | • | ||
Data Transfer | 600+ | 500+ | 400+ |
1D and 2D Scanner connectivity | • | • | Reads 1D Data Only |
Read QR code (2D) labels with 2D scanner | • | • | |
RFID reader connectivity | • | • | |
Print Pass & Fail labels with 1D barcode | • | • | • |
Print Pass & Fail labels with QR code (2D) | • | • | |
Add your company logo to labels (on large 1D labels only) | • | • | |
Select from various label formats to print | 6 | 6 | 6 |
Download to PC via USB cable | • | • | • |
Data Transfer via USB flash drive | • | ||
Filter results to be downloaded | • | • | • |
Upload previous results to the tester for a retest | • | • |