All Seaward Products

Seaward Apollo 500+ PAT Tester Elite Bundle Kit

SKU
380A9899-KIT
Rating:
0%
(0)
Reward Points
:
2549
£3,058.80 £2,549.00
In Stock
Free UK Delivery*
Choose a Special Offer
  • PASS The Complete Guide to EET (PAT) Testing Cover
    PASS The Complete Guide to EET (PAT) Testing, 5th Edition
    FREE
    £24.99
  • PASS The Complete Guide to EET (PAT) Testing, 5th Edition SKU: (PASS-PAT-HB)
    FREE
    £24.99
    PASS The Complete Guide to EET (PAT) Testing Cover
    • Covers 5th Edition IET Code of Practice updates
    • 129 page in-depth PAT/EET guide
    • Easy to understand with lots of examples
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
FREE ELITE Software + Accessories
Seaward Apollo 500+ PAT Tester Elite Bundle Kit
Seaward 1 Year PAT Guard 3 Licence

The Seaward Apollo 500+ PAT Tester Elite Bundle Kit includes the following products:

  • 1x Seaward Apollo 500+ PAT Tester
  • 1x Seaward Test ‘n’ Tag Elite Bundle Kit

For further information regarding these products, please see the descriptions below.

Seaward Apollo 500+ PAT Tester Description

Seaward Apollo 500+ PAT Tester | Introduction | Key Features

This instrument has been optimised for conducting extensive checks on high-volumes of portable appliances. It features a comprehensive onboard memory (10 000-record capacity) and the following measurement capabilities:

  • Low current earth continuity test with Zap circuit, guaranteeing accurate measurements
  • Insulation resistance test
  • IEC lead test
  • Protective conductor current test
  • Touch current test
  • Load power/ current test
  • Alternative leakage current test
  • RCD test
  • Power socket test
  • Class 2 FE (5th edition update) 

In addition to this, the Seaward Apollo 500+ PAT Tester is capable of performing point-to-point fixed appliance testing for earth continuity and insulation resistance.  This instrument’s extensive measurement capabilities make the Seaward Apollo 500+ PAT Tester suitable for ensuring compliance with the IET 5th Edition Code of Practice. These electrical and visual tests can be organised into up to 100-customised sequences, allowing the user to tailor the tester to his/her requirements.

Adding to this instrument’s practicality is the inclusion of an integrated electrical risk assessment tool with a retest calculator, allowing the user to determine suggested retest periods.

Further to this, the Seaward Apollo 500+ PAT Tester, when used with the below Seaward Test ‘n’ Tag Elite Bundle Kit and/or Seaward’s FREE QR Data Viewer App, can be used to read, create and print 2D QR codes. This facilitates quicker retesting and allows the user to manage appliances more effectively.

Firmware Features

This instrument’s firmware update also adds to the practicality and efficiency of the Seaward Apollo 500+ PAT Tester. The following updates add to the versatility of this instrument and allow the user to tailor it to his/her preferences:

  • New user permissions for Bluetooth
  • Option to delete unwanted results
  • ‘View Data Menu’ has been optimised to facilitate faster scrolling
  • Advanced search function – filter results using various specifications such as the PASS/ FAIL status of each test
  • ‘After Test’ function includes the option to print test results automatically
  • ‘Worst’ and ‘Last’ options included in the Leakage Test settings
  • Predictive drop-down menus can be tailored to the user’s preferences via the deletion of unwanted options
  • USB on-the-go technology facilitates the user’s ability to download information directly to an Android device
  • Name downloaded files using unique identifiers to ensure that they are easy to locate
  • The inclusion of a socket outlet test allows the user to measure main voltage and outlet wiring polarity
  • Asset ID is displayed on each test screen
  • Addition of a Review Step allows the user to check test details prior to adding any final comments
  • 2020 5th Edition update includes a brand-new set of test sequences including Class 2 FE and other new tests as per the 5th Edition

The new 5th Edition firmware will also be available to download free of charge for current Apollo users who will be able to update to the new firmware and benefit from the new test features.

Note: in existing Apollos touch current tests will be limited by the hardware to 3.5mA.

Software Compatibility

Improvements to the Seaward Apollo 500+ PAT Tester’s software compatibility also facilitates the user‘s ability to review results, as well as create reports using the collected data. These capabilities are made possible by the Seaward Apollo 500+ PAT Tester’s compatibility with Seaward’s PAT Guard 3.4 Software with Time Manager (NOT included). This software can also be used to manage teams of workers.

Alternatively, results can be sent to compatible smartphones and/or tablets via Bluetooth.

Hardware Features

Results are also viewable via the Seaward Apollo 500+ PAT Tester’s high-definition, colour display. Furthermore, the Seaward Apollo 500+ PAT Tester can be operated using its full QWERTY keyboard. The Seaward Apollo 500+ PAT Tester shares these features with the Seaward Apollo 500.

However, the design of this instrument differs from its predecessor with the inclusion of an interchangeable, rechargeable battery pack. This PAT tester can be powered using its battery pack or via a mains supply thereby ensuring that downtime is kept to a minimum.

Further to this, the Seaward Apollo 500+ PAT Tester is supplied with a test leads featuring stronger PVC insulation and resilient test probes, making the instrument better suited to challenging environments and more demanding applications.

The Seaward Apollo 500+ PAT Tester is an adaptable, practical, reliable PAT Tester ideal for comprehensively checking high-volumes of portable appliances.

The 2020 5th edition hardware update also allows for the increase in protective and touch leakage limits to 5mA rather than 3.5m.A.

Seaward Apollo 500+ PAT Tester Key Features

  • An updated version of the Seaward Apollo 500 PAT Tester
  • Includes improvements to its firmware, hardware and software compatibility
  • Optimised for checking high-volumes of portable appliances
  • Extensive onboard memory (capacity for 10 000 records)
  • Low current earth continuity test with Zap circuit, guaranteeing accurate measurements
  • Insulation resistance test
  • IEC lead test
  • Protective conductor current test
  • Touch current test
  • Load power/ current test
  • Alternative leakage current test
  • RCD test
  • Power socket test
  • Capable of performing point-to-point fixed appliance testing for earth continuity and insulation resistance
  • Suitable for ensuring compliance with the IET 5th Edition Code of Practice
  • Create up to 100 customised visual and electrical test sequences
  • Integrated electrical risk assessment tool with retest calculator
  • Capable of reading, creating and printing 2D QR codes when used with the below accessories or Seaward’s FREE QR Data Viewer App
  • New user permissions for Bluetooth
  • Option to delete unwanted results
  • ‘View Data Menu’ has been optimised to facilitate faster scrolling
  • Advanced search function – filter results using various specifications such as the PASS/ FAIL status of each test
  • ‘After Test’ function includes the option to print test results automatically
  • ‘Worst’ and ‘Last’ options included in the Leakage Test settings
  • Predictive drop-down menus can be tailored to the user’s preferences via the deletion of unwanted options
  • USB on-the-go technology facilitates the user’s ability to download information directly to an Android device
  • Name downloaded files using unique identifiers to ensure that they are easy to locate
  • The inclusion of a socket outlet test allows the user to measure main voltage and outlet wiring polarity
  • Asset ID is displayed on each test screen
  • Addition of a Review Step allows the user to check test details prior to adding any final comments
  • Compatible with Seaward’s PAT Guard 3.4 Software with Time Manager (NOT included)
  • Bluetooth communication capabilities
  • High-definition, colour display
  • QWERTY keyboard
  • Interchangeable, rechargeable battery pack
  • Can be powered using a battery pack or a mains power supply
  • Includes test leads with stronger PVC insulation
  • Includes resilient test probes
  • Suitable for challenging environments
  • Suitable for more demanding applications
  • An adaptable, practical and reliable PAT tester

Seaward Test ‘n’ Tag Elite Bundle Kit Description

The Seaward Test ‘n’ Tag Elite Bundle Kit can be used with the Seaward Apollo 500+ PAT Tester in order to read, create and print 2D QR codes.

This kit includes:

  • 1x Test ‘n’ Tag Elite 2 Printer: allows the user to print labels with QR codes
  • 1x 2D Barcode Scanner: facilitates quick retesting via scanning QR codes in order to access previous test information which will automatically populate the relevant fields in the Seaward Apollo 500+ PAT Tester’s set-up
  • 2x Elite Durable Labels 25mm
  • 2x Elite Durable Labels 75mm
  • Apollo Kit Carry Case
  • 110V Test Adapter

The Seaward Test ‘n’ Tag Elite Bundle Kit is ideal for extending the capabilities of the Seaward Apollo 500+ PAT Tester.

What’s Included in the Seaward Apollo 500+ PAT Tester Elite Bundle Kit?

  • 1x Seaward Apollo 500+ PAT Tester
  • 1x Seaward Test ‘n’ Tag Elite Bundle Kit
Seaward 1 Year PAT Guard 3 Licence

For the rest of the year, when you buy a Seaward Apollo 500+ or Seaward Apollo 600+ PAT Tester or PAT Testing Kit, you’ll receive a FREE one-year licence to Seaward’s PATGuard 3 Testing and Reporting Software, worth £146. This limited offer is only available to UK customers until the 31st of December 2024. For further details please visit the FREE Seaward PATGuard 3 Licence Page.

Free Complete Guide to EET (PAT) Testing
  • PASS The Complete Guide to EET (PAT) Testing, 5th Edition - PASS-PAT-HB, typically £24.99

Seaward Apollo 500+ PAT Tester Technical Specifications 

Earth Continuity  
Test Current +/- 200mA DC
Display Range 0.01 – 19.99Ω
Pass Value User Defined
Insulation Resistance  
Test Voltage 500V / 250V DC @ 1mA nominal
Display Range 0.01MΩ - 19.99MΩ
Pass Value User Defined
IEC Lead Test  
Test Voltage 5V ac nominal
Test Live / Neutral Checks for o/c, s/c and crossed
Protective Conductor Current/Load  
Test Voltage Supply voltage, maximum load current 16A
Display Ranges 0.01mA to 19.99mA
Pass Value User Defined
Touch Current  
Test Voltage Supply Voltage, maximum load current 16A
Display Range 0.00 – 5mA
Pass Value User Defined
Load Power/Current  
Test Voltage Supply Voltage, maximum load current 16A
Test Duration Programmable up to a maximum of 255s
depending on load. i.e. max duration is reduced
for high loads
Display Range 0.00kVA – 4.00kVA
0.00A – 16.00A
Alternative Leakage Current  
Test Voltages >25Vac <50Vac
Display Range 0.00mA to 19.99mA
Pass Value User Defined
RCD Test  
Test Voltage 230V +10%, -15%
Test Current 30mA / 150mA rms sinusoidal
Display Range 0ms - 2000ms (30mA), 0-40ms (150mA)
Test Method Internal isolation to avoid tripping distribution
board RCD
Power Socket Test  
Voltage Range 207V – 253V AC
Indicates configuration of voltage potential:-
Line potential phase to earth
Line potential phase to neutral
Line potential neutral to earth
General  
Memory Size 10000 Records
Weight 1.5kg
Dimensions 230mm x 150mm x 100mm
Power Source Mains or Rechargeable Battery Pack

Seaward Apollo+ PAT Tester Comparison Chart

General Features 600+ 500+ 400+
Battery & mains powered
Colour screen & QWERTY keypad
Large internal memory up to 50,000 records and 2,000 photos up to 10,000 records up to 2,000 records
Bluetooth scanner & printer compatible
Password controlled user accounts  
Set up multiple user accounts with varying levels of privileges  
Clone facility to set up multiple testers  
Checkbox supplied as standard  
Test Inspection Features 600+ 500+ 400+
Auto-increment asset ID  
PAT Setup option to allow for custom menus  
Enter asset description after test using the keypad or barcode scanner
Comprehensive electrical safety test features 
Point to point measurement (Rpe & IR)  Optional accessory required
User configurable electrical test/visual inspection sequences 100 100 25
User set sites & locations 100 100 50
Risk-based retest period calculator  
User definable comments lines against test records 4 4  
Configurable checklists for any workplace test or inspection (user tests)  
Onboard camera    
Universal risk assessment    
Health & safety certificates    
Data Transfer 600+ 500+ 400+
1D and 2D Scanner connectivity Reads 1D Data Only
Read QR code (2D) labels with 2D scanner  
RFID reader connectivity  
Print Pass & Fail labels with 1D barcode
Print Pass & Fail labels with QR code (2D)  
Add your company logo to labels (on large 1D labels only)  
Select from various label formats to print 6 6 6
Download to PC via USB cable
Data Transfer via USB flash drive    
Filter results to be downloaded
Upload previous results to the tester for a retest  
Seaward Apollo+ PAT Tester - Datasheet Datasheets

Reviews

Additional Information
SKU 380A9899-KIT
Manufacturer Part Code 380A9899-KIT
Model Ref APOLLO 500 ELITE