The Seaward 423A912 is a combination of the Seaward 423A910 Dual Live Line Tester MKII and the Seaward 423A911 PH3-LLT MKII Proving Unit.
Dual Live Line Tester MKII
Ideal for live line testing on systems up to 1100V DC and is encapsulated in a high-impact rugged enclosure with high-visibility cable. The unit is fitted with high-intensity red LED indicators and a polarizing filter on each handle makes it visible, even in direct sunlight.
Designed specifically for live line applications, the LLT MK2 enables the user to check that conductor rails have been isolated before maintenance or inspection work commences on rail track systems.
Features
- Polarising filters make viewing easier
- High-intensity red LEDs
- LEDs in both handles
- BS EN 50122 threshold compliant
LLT Live Line Voltage Detector | |
---|---|
Maximum Working Voltage | 1100V DC |
Threshold Voltage | 80V AC/120V DC |
Circuit Current | <10mA |
Indicator | High-intensity LEDs with polarising filters |
Threshold Compliance | BS EN 50122 |
PH3-LLT MKII Proving Unit
The PH3 MK2 is a highly portable, battery-powered unit for proving the live line testers' function in the field. This proving unit produces a DC output voltage from a 9v PP3 battery source that lights up the red indicator when active.
It is essential to prove that the Live Line Tester is functional both before and after testing the DC system to be worked on. The MK2 version has an integrated case that protects the unit when not in use. The wider base improves stability when using the unit in the field and also holds the operating instructions for added convenience and ease of use.
Features
- Red indication showing when the unit is active
- Integrated case to protect the unit
- Wide base to aid stability on uneven ground
- Instructions for use printed on the case
- Output Voltage: 500V DC nominal
- Output Current: 10mA into 2k ohms
- External Dimensions 175 x 115 x 47 mm
- Weight 0.16kg
- Range Temperature -10 / 80°C
Dual Live Line Tester MKII Physical Dimensions | ||
---|---|---|
Handle Length | 109 mm | |
Overall Length | 270 mm | |
Handle Diameter | 33 mm | |
Probe Tip Length | 16 mm | |
Hand Guard Height | 27mm over the full circumference | |
Distance from Uninsulated Probe | Tip to Hand Guard | 145 mm |
Uninsulated Contact | Electrode Length | 5mm |
Contact Electrode Diameter | 3mm | |
Lead Length between Probes | 1.7m | |
Construction | High Impact, total encapsulation |
Reviews
SKU | 423A912 |
---|---|
Manufacturer Part Code | 423A912 |