Metrel MI3360 OmegaPAT XA PAT Tester - Kit 1
This kit includes the Metrel MI3360 OmegaPAT XA PAT Tester with standard accessories, alongside additional PAT testing tools. It's designed for testing Class I, Class II, and Class III portable appliances commonly found in hotels, schools, and public institutions.
Key Features
Comprehensive Testing Capabilities: Covers visual inspection, fuse testing, continuity/earth bond resistance (200mA), insulation resistance (Riso, Riso-S), leakage current tests (substitute, differential, PE, touch), polarity/active polarity tests, power tests (P, S, Q, PF, THDu, THDi, CosØ, I, U), various RCD tests, and more
Expandable Functionality: Can be expanded with optional adapters like the Metrel A1422 Active 3-phase Adapter for welding equipment testing, and Metrel A1283 Current Clamp Adapter for measuring leakage current
User-Friendly Interface: Features a high-resolution 4.3-inch TFT touchscreen display and a keyboard for easy navigation. Supports multiple user accounts for personalized settings and test records
Data Management: Saves test sequences and results on an 8GB microSD card, facilitating easy recall and reporting using Metrel ES Manager BASIC Software. Bluetooth connectivity enables integration with the Metrel aMESM Android SW App for streamlined data handling
The Metrel MI3360 OmegaPAT XA PAT Tester - Kit 1 is a versatile and comprehensive tool ideal for professionals needing to ensure compliance and safety across a wide range of portable appliances.
What’s Included?
- Accessory Bag (supplied by Metrel)
- Smartball Pen with Touchscreen Function (supplied by Metrel)
- Black Crocodile Clip (supplied by Metrel)
- Black Test Lead (supplied by Metrel)
- Black Test Tip (supplied by Metrel)
- 2m IEC Test Cable (supplied by Metrel)
- Mains Cable (supplied by Metrel)
- USB Cable (supplied by Metrel)
- Calibration Certificate (supplied by Metrel)
- Short Form Instruction Manual (supplied by Metrel)
- CD with Instruction Manual (supplied by Metrel)
- Metrel ES Manager BASIC Software (supplied by Metrel)
Extras included with Bundle
- Socket Tester
- eLearning PAT Testing Course - Includes Exam and Certificate
- Microwave Leakage Detector
- 2x 110V Adapters
- 3x IEC Adapters
- 5 Piece Insulated Screwdriver Kit
- 1000x Passed PAT Testing Labels
- 500x Circular Passed PAT testing Labels
- 500x Cable Wrap Labels
- 250x Failed PAT Testing Labels
Metrel MI3360 OmegaPAT XA PAT Tester Technical Specifications
Continuity / Protective Earth Resistance | |
Continuity | |
Ranges | 0.00 Ω … 19.99 Ω / 20.0 Ω … 99.9 Ω / 100.0 Ω … 199.9 Ω / 200 Ω … 999 Ω |
Resolution | 0.01 Ω / 0.1 Ω / 0.1 Ω / 1 Ω \ |
Accuracy | ±(2 % of reading + 2 D) / ± 3 % of reading / ± 5 % of reading / indicative |
Operating range (acc. to EN 61557-4) | 0.08 Ω … 199.9 Ω |
Test currents | 0.2 A,10 A, 25 A |
Current source (at nominal mains voltage, use of standard accessories) | > 0.2 A at R < 2 Ω |
> 10 A at R < 0.1 Ω at 230 V | |
> 25 A into short circuit at 230 V | |
Open circuit voltage | < 9 V a.c. |
Test Terminals | |
Continuity | |
R (200 mA) | P/S – PE, Socket PE; Socket PE – IEC PE |
R (10 A, 25 A) | P/S – Socket PE; Socket PE – IEC PE |
Protective Earth Resistance | |
R (200 mA) | P/AP – PE, Socket PE |
R (10 A, 25 A) | P/AP – Socket PE |
Insulation Resistance (Riso, Riso-S) | |
Insulation resistance, Insulation resistance –S (250 V, 500 V) | |
Range | 0.00 MΩ … 19.99 MΩ / 20.0 MΩ … 99.9 MΩ / 100.0 MΩ … 199.9 MΩ |
Resolution | 0.01 MΩ / 0.1 MΩ / 0.1 MΩ |
Accuracy | ±(3 % of reading + 2 D) / ± 5 % of reading /± 10 % of reading |
Output voltage (Um) | |
Range | 0 V … 600 V |
Resolution | 1V |
Accuracy | ±(3 % of reading + 2 D) |
Operating range (acc. to EN 61557-2) | 0.08 MΩ … 199.9 (999) MΩ |
Nominal voltages Un | 250 V, 500 V (- 0 %, + 10 %) |
Short circuit current | max. 2.0 mA |
Test terminals | Riso LN, Socket LN – PE, Socket PE, P/S |
Riso-S LN, Socket LN – P/S | |
Sub-Leakage Current, Substitute Leakage Current - S (Isub, Isub-S) | |
Range | 0.00 mA … 1.99 mA / 2.00 mA … 19.99 mA |
Resolution | 0.01mA / 0.01mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Operating range (acc. to EN 61557-16) | 0.02 mA … 19.99 mA |
Open circuit voltage | 230 V a.c., 110 V a.c. |
Current calculated to mains supply voltage (110 V or 230 V) is displayed. | |
Test Terminals | Isub LN, Socket LN – PE, Socket PE, P/S |
Isub-S LN, Socket LN – P/S | |
Differential leakage current (Idiff) | |
Differential leakage current | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1 µA / 0.01 mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Influence of load current | < 0.02 mA/A |
Test terminals | Idiff Socket L,N – Socket PE, P/S |
P Socket L – Socket N | |
PE leakage current (Ipe) | |
PE leakage current | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1µA / 0.01mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Test terminals | Ipe Socket L,N – Socket PE |
P Socket L – Socket N | |
Touch leakage current (Ipe) | |
Touch leakage current | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1 µA / 0.01mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Test terminals | Itou: Socket L,N – P/S |
P: Socket L – Socket N | |
Power | |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power (apparent) (S) | |
Range | 0 VA … 999 VA / 1.00 kVA … 3.70 kVA |
Resolution | 1 VA / 10VA |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power (reactive) (Q) | |
Range | ±(0 VAr … 999) VAr / ±(1.00 kVAr … 3.70) kVAr |
Resolution | 1 VAr / 10 VAr |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power factor (PF) | |
Range | 0.00i … 1.00i / 0.00c … 1.00c |
Resolution | 0.01 |
Accuracy | ±(5 % of reading + 5 D) |
Total Harmonic Distortion (voltage) (THDU) | |
Range | 0.0 % … 99.9 % |
Resolution | 0.1 % |
Accuracy | ±(5 % of reading + 5 D) |
Total Harmonic Distortion (current) (THDI) | |
Range | 0.00 A … 16.00 A |
Resolution | 0.01 A |
Accuracy | ±(3 % of reading + 5 D) |
Cosinus Φ (Cos Φ) | |
Range | 0.00i … 1.00i / 0.00c … 1.00c |
Resolution | 0.01 |
Accuracy | ±(5 % of reading + 5 D) |
Current (I) | |
Range | 0.00 A … 16.00 A |
Resolution | 0.01 A |
Accuracy | ±(3 % of reading + 5 D) |
Voltage (U) | |
Range | 0.0 V … 199.9 V / 200 V … 264 V |
Resolution | 0.1V / 1V |
Accuracy | ±(3 % of reading + 10 D) / ±3 % of reading |
Test terminals | |
P,S,Q,PF,THDU,THDI, Cos Φ, I, U | Socket L – Socket N |
Leaks & Power | |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Touch leakage current: (Itou) | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1 µA / 0.01 mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Differential leakage current (Idiff) | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1 µA / 0.01 mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Influence of load current | < 0.02 mA/A |
Power (apparent) (S) | |
Range | 0 VA … 999 VA / 1.00 kVA … 3.70 kVA |
Resolution | 1 VA / 10VA |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power (reactive) (Q) | |
Range | ±(0 VAr … 999) VAr / ±(1.00 kVAr … 3.70) kVAr |
Resolution | 1 VAr / 10 VAr |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power factor (PF) | |
Range | 0.00i … 1.00i / 0.00c … 1.00c |
Resolution | 0.01 |
Accuracy | ±(5 % of reading + 5 D) |
Total Harmonic Distortion (voltage) (THDU) | |
Range | 0.0 % … 99.9 % |
Resolution | 0.1 % |
Accuracy | ±(5 % of reading + 5 D) |
Total Harmonic Distortion (current) (THDI) | |
Range | 0.00 A … 16.00 A |
Resolution | 0.01 A |
Accuracy | ±(3 % of reading + 5 D) |
Cosinus Φ (Cos Φ) | |
Range | 0.00i … 1.00i / 0.00c … 1.00c |
Resolution | 0.01 |
Accuracy | ±(5 % of reading + 5 D) |
Current (I) | |
Range | 0.00 A … 16.00 A |
Resolution | 0.01 A |
Accuracy | ±(3 % of reading + 5 D) |
Voltage (U) | |
Range | 0.0 V … 199.9 V / 200 V … 264 V |
Resolution | 0.1V / 1V |
Accuracy | ±(3 % of reading + 10 D) / ±3 % of reading |
Test terminals | |
P,S,Q,PF,THDU,THDI, Cos Φ, I, U | Socket L – Socket N |
Idiff | Socket L,N – Socket PE, P/S |
Itou | Socket L,N – P/S |
PRCD test | |
Trip-out time (tΔN) | |
Range | 0 ms … 300 ms (999 ms*) (½xI∆N) / 0 ms … 300 ms (I∆N) / 0 ms … 40 ms (5xI∆N) |
Resolution | 1ms / 1ms / 1ms |
Accuracy | ±3ms / ±3ms / ±3ms |
*According to standard AS/NZS 3017 | |
Trip out-current (IΔ) | |
Range | 0.2xI∆N … 2.2xI∆N |
Resolution | 0.05xI∆N |
Accuracy | ±0.1xI∆N |
Test current type | sine-wave (AC), pulsed (A,F), smooth DC (B,B+) |
Test currents (IΔN) | 10 mA, 15 mA, 30 mA;.................100 mA and 300 mA with A1322, A1422 |
Test current size (PRCD standard is AS/NZS 3017) | ±5% |
Test current size (general) | -0/+10% |
Test terminals | tΔN, IΔ Socket – IEC |
RCD Test | |
Trip-out time (tΔN) | |
Range | 0 ms … 300 ms (999 ms*) (½xI∆N) / 0 ms … 300 ms (I∆N) / 0 ms … 40 ms (5xI∆N) |
Resolution | 1ms / 1ms / 1ms |
Accuracy | ±3ms / ±3ms / ±3ms |
*According to standard AS/NZS 3017 | |
Trip out-current (IΔ) | |
Range | 0.2xI∆N … 2.2xI∆N |
Resolution | 0.05xI∆N |
Accuracy | ±0.1xI∆N |
Contact voltage (Uc) | |
Range | 0.0 V … 19.9 V / 20.0 V … 99.9 V |
Resolution | 0.1V / 0.1V |
Accuracy | (-0 % / +15 %) of reading ± 10 D / 0.1 V (-0 % / +15 %) of reading |
Test current type | sine-wave (AC), pulsed (A,F), smooth DC (B,B+) |
Test currents (IΔN) | 10 mA, 15 mA, 30 mA |
Test current size (RCD standard is AS/NZS AS/NZS) | 5% |
Test current size (EN 61008/EN 61009) | -0/+10% |
Test terminals | tΔN, IΔ Mains Socket |
PE conductor (PRCD) | |
PE conductor (Type = 2 pole, 3 pole, S(3 pole)) (R) | |
Range | 0.00 Ω … 19.99 Ω / 20.0 Ω … 99.9 Ω / 100.0 Ω … 199.9 Ω / 200 Ω … 999 Ω |
Resolution | 0.01 Ω / 0.1 Ω / 0.1 Ω / 1 Ω |
Accuracy | ±(2 % of reading + 2 D) / ± 3 % of reading / ± 5 % of reading / indicative |
Operating range (acc. to EN 61557-4) | 0.08 Ω … 199.9 Ω |
Current source (at nominal mains voltage, use of standard accessories) | > 0.2 A at R < 2 Ω |
Open circuit voltage | < 9 V a.c. |
Test terminals | R Socket PE – IEC PE |
PE conductor (Type = K/ Di (varistor)) | |
Test principle: A voltage is applied between PE connections of the PRCD-K. There is a ‘PASS’ if PRCD trips. | |
Open circuit voltage | 24 V |
Output resistance | 220 Ω ± 10 % (IΔN = 30 mA), 620 Ω ± 10 % ((IΔN = 10 mA) |
Test terminals | Result: Socket – IEC |
Open conductor (PRCD) | |
Test principle: Mains voltage is applied to the mains test socket. Disconnection of the L, N and PE connections is performed inside the instrument. There is a ‘PASS’ if the PRCD trips. | |
Test terminals | L open, N open, PE open Socket – IEC |
PRCD PE probe test | |
Test principle: Mains voltage is applied to the mains test socket. A safe voltage sufficiently high to activate the protection circuit in the PRCD is applied to the P/S terminal. | |
Test terminals | Result (manual): Socket, P/S |
Result (auto): Socket – IEC, P/S | |
Polarity | |
Test voltage (normal) | < 50 V |
Test voltage (active) | mains voltage |
Power consumption of tested device during the active test | < 25 VA |
Test terminals | Result (normal, active) Socket – IEC |
Clamp current (I, Idiff, Ipe) | |
True RMS current using 1000:1 current clamp | |
Range | 0.10 mA … 9.99 mA / 10.0 mA … 99.9 mA / 100 mA … 999 mA / 1.00 A … 9.99 A / 10.0 A … 24.9 A |
Resolution | 0.01 mA / 0.1 mA / 1 mA / 0.01 A / 0.1 A |
Accuracy | ±(5 % of reading + 10 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) |
Notes | Accuracy of current transformer is not considered. |
Frequency range of current clamp is not considered. | |
Test terminals | I, Idiff, Ipe: CLAMPS terminals |
Insulation resistance Riso (welding equipment) | |
Riso | |
Range | 0.00 MΩ … 19.99 MΩ / 20.0 MΩ … 99.9 MΩ / 100.0 MΩ … 199.9 MΩ |
Resolution | 0.01 MΩ / 0.1 MΩ / 0.1 MΩ |
Accuracy | ±(3 % of reading + 2 D) / ±5 % of reading / ±10 % of reading |
Output voltage (Um) | |
Range | 0 V … 600 V |
Resolution | 1 V |
Accuracy | ±(3 % of reading + 2 D) |
Operating range (acc. to EN 61557-2) | 0.08 MΩ … 199.9 (999) MΩ |
Nominal voltages Un | 500 V (- 0 %, + 10 %) |
Short circuit current | max. 2.0 mA |
Test terminals | |
Riso LN-W: A 1422 | Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – W1 W2 |
Riso W-PE | A 1422: Socket PE (16A-5p, 32A-5p or 16A-3p) – W1 W2 |
Riso LN-PE | A 1422: Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – Socket PE (16A-5p, 32A-5p or 16A-3p) |
Riso LN (Class II) - P | A 1422: Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – MI 3360: P/S |
General Specifications | |
Mains supply | |
Supply voltage, frequency | 110 V / 230 V AC, 50 Hz / 60 Hz |
Supply voltage tolerance | 10 % |
Max. power consumption | 300 VA (without load on test socket) |
Max. load | 10 A continuous, 16 A short duration, 1.5 kW motor |
Mains supply overvoltage category | CAT II / 300V |
Altitude | ≤ 2000 m |
Measuring categories | |
Instrument | Cat II / 300 V |
Test socket | Cat II / 300 V |
Plug test cable | Cat II / 300 V |
Altitude | ≤ 2000 m |
Protection classifications | |
Power supply | Mains supply |
Pollution degree | 2 |
Degree of protection | IP40 |
IP20 (mains test socket) | |
Case | Shock proof plastic / portable |
Display | Colour TFT display, 4.3 inch, 480 x 272 pixels |
Touch screen | Capacitive |
Communication | |
Memory | depends on microSD card size |
RS232 interfaces | 2 |
USB 2.0 | Standard USB Type B |
Bluetooth | Class 2 |
Dimensions (w×h×d) | 31 cm × 13 cm × 25 cm |
Weight | 6.1 kg |
Reference conditions | |
Reference temperature range | 15 ˚C … 35 ˚C |
Reference humidity range | 35 % … 65 % RH |
Operation Conditions | |
Working temperature range | 0 ˚C … +40 ˚C |
Maximum relative humidity | 85 % RH (0 ˚C … 40 ˚C), non-condensing |
Storage Conditions | |
Temperature range | -10 ˚C … +60 ˚C |
Maximum relative humidity | 90 % RH (-10 ˚C … +40 ˚C) |
80 % RH (40 ˚C … 60 ˚C) | |
Notes | Accuracies apply for 1 year in reference conditions. Temperature coefficient outside these limits is 0.2 % of measured value per ˚C plus 1 digit, otherwise noted. |
Fuses | 2 x T 16 A / 250 V, 32 mm 6.3 mm / 1500 A |