This winter when you buy over £100 worth of Mitutoyo products online you’ll receive either a free Mitutoyo Engineers’ Reference Book or a Metrology Handbook depending on the value of your item(s). Available for a limited time or while stocks last, this offer is perfect for metrology professionals and engineers requiring a reference guide complete with conversions, measurement principles, standards, and practices. For further details visit the Mitutoyo Online Offer Free Book Page
SKU | Range | Resolution (selectable) | Max. permissible error | ||
---|---|---|---|---|---|
MPEE*¹ | Hysteresis MPEH | Repeatability MPER | |||
MIT-543-351B | .5" / 12.7 mm | .00005" .0001", .005" / 0.001, 0.01 mm | ±.0001" / 0.003 mm | .0001" / 0.002 mm |
*¹Error of indication for the total measuring range.
Note 1: LCD readout does not rotate.
Note 2: MAX/MIN holding: sample rate is 100 readings/s; max. rate of change of reading is 100 µm/s or less.
Wire | - NG | OK | + NG | Composition Error |
---|---|---|---|---|
Orange (- NG) | Low | High | High | High |
Green (OK) | High | Low | High | High |
Brown (+ NG) | High | High | Low | High |
LCD | ◄ | Ο | ► | "x.xxE" indication |
Wire | Signal | I/O | Description |
---|---|---|---|
Black | - V (GND) | — | Connected to minus (-) terminal |
Red | + V | I | Power supply (5-24VDC) |
Orange | -NG | O | Tolerance judgement result output: Only the terminal corresponding to a judgement result is set to the low level. |
Green | OK | O | |
Brown | + NG | O | |
Yellow | PRESET_RECALL ZERO | I | External input terminal: If the relevant terminal is set to the low level, its signal becomes true. |
Blue | PEAK_START | I | |
Shield | FG | — | Connected to GND (earth) |
Note: Measurement data cannot be output.
Digital/Analog | Digital |
---|---|
Measuring force MPL | ≤2.5 N |
Protection | IP54 |
Type | EN ISO Standard |
Scale | Electrostatic capacitance type absolute linear encoder |
Display | LCD, character height 8 mm |
Max. Response Speed | Unlimited |
Measurement Frequency (MAX/MIN/RANGE) | Standard mode: 100 times/s (plunger speed max. 0.1mm/s for peak measurement) |
Alarm | Low voltage, ABS composition error, overflow error, setting error |
Stem Ø | 8 mm |
Contact Point | Carbide ball, thread: M2.5x0.45 |
Power Supply | 5 - 24 V DC / 100mA (max) |
PRESET 3x | Yes |
ON/OFF | Yes |
Analog Bar Resolution Switchable | Yes |
Function Lock | Yes |
GO/±NG Judgement | Yes |
Signal output: (+NG, OK, -NG) | Yes |
Signal input: No-voltage input (PRESET_RECALL/ZERO, HOLD_RESET) | Yes |
ABS / INC (INC ZERO) | Yes |
GO/±NG Judgement via LED | Yes |
Calculation Function (with formula) | Yes |
Counting Direction Switchable | Yes |
Inch/Metric Switchable | Yes |