These Micronics ultrasonic permanent/fixed clamp-on flow meters are a solution for measuring flow rate and total flow with a volume pulse output and optional Modbus or 4-20mA flow proportional output, which can be used as a stand-alone meter or as part of an integrated management system.
A cost-effective alternative to traditional in-line meter installation, plus dry servicing, providing minimum downtime and maximum availability! Compact, rugged, and reliable, and designed to provide sustained performance in industrial environments.
Simple to install - connect power enter the pipe inside diameter and material, adjust the sensors, and clamp on the pipe - no specialist skills or tools required!
Features
- Wall Mounted keypad and display for wall or panel mounting
- Larger pipe range 2 options, fully adjustable for 22mm - 115mm and 125mm - 180mm (6″) OD
- Optional Modbus RTU slave, RS485 serial, and M-Bus communication
- Cross-correlation flow measurement system
- 1Mhz transducers to get through poor/old thick wall pipes and larger pipework
- Water/Glycol option
- Connect power and enter the pipe inside diameter, adjust the sensors, and clamp on the pipe, no specialist skills or tools are required
- A clamp-on non-invasive alternative to traditional in-line meter installation, plus dry servicing, providing minimum downtime and maximum availability
- LCD with backlight - install & service information
- Integrated pulse and optional 4-20mA output - aM&T & BEM's compatible with Modbus
Product Range
- Micronics 904-11001400 U1000MKII WM-FM Pulse Only, up to 4' pipe Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11001401 U1000MKII WM-FM with Pulse & 4-20mA, up to 4' Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11001402 U1000MKII WM-FM with Pulse & Modbus, up to 4' Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11001403 U1000MKII WM-FM with Pulse & Mbus, up to 4' Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11001404 U1000MKII WM-FM with Pulse, 4-20mA & Modus, up to 4' Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11001405 U1000MKII WM-FM with Pulse, 4-20mA & Mbus, up to 4' Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11004800 U1000MKII WM-FM Pulse Only, up to 8' pipe Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11004801 U1000MKII WM-FM with Pulse & 4-20mA, up to 8' Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11004802 U1000MKII WM-FM with Pulse & Modbus, up to 8' Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11004803 U1000MKII WM-FM with Pulse & Mbus, up to 8' Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11004804 U1000MKII WM-FM with Pulse, 4-20mA & Modus, up to 8' Fixed Ultrasonic Clamp-on Heat Meter
- Micronics 904-11004805 U1000MKII WM-FM with Pulse, 4-20mA & Mbus, up to 8' Fixed Ultrasonic Clamp-on Heat Meter
Manuals & Guides
Brochures & Catalogues
Specification | |
---|---|
Measurement Technique | Ultrasonic, cross-correlation transit time method for flow measurement |
Turn Down Ratio | 100:1 |
Accuracy | ±3% of flow reading for velocity rate >0.3m/s (>1 ft/s) |
Flow Velocity Range | 0.1m/s - 10m/s (0.3 ft/s - 32 ft/s) |
Water Temp Range | 0°C - 135°C (32°F - 275°F) |
Pipe Material | Steel, Stainless Steel, Plastic, and Copper |
4-20mA Output | Optional 4-20mA flow proportional output Resolution 0.1% of the full scale Maximum load 620Ω |
Pulse Output | Pulse or Frequency. Pulse for Volume flow and Alarms Frequency for flow rate The pulse output can be configured as a loss of signal or low-flow alarm Opto-isolated MOSFET volt free contact (NO/NC) |
Modbus Communication | Optional Modbus RTU slave, RS485 serial link hardware layer Physical connection RS485 |
External Power Supply | 12V - 24V ±10% AC/DC at 7 watts per unit Optional plug-in 12V power supply |
Electronics Enclosure | IP68 |
Wall Mounted Keypad and Display Dimensions | 215mm x 125mm x 90mm (8.46"x 4.92" x 3.54") |
Reviews
SKU | 904-1100XX0X |
---|