The Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter is a permanent/ fixed clamp-on metering solution that utilises ultrasonic technology to measure flow rate and total flow from outside the pipe. All models include a volume pulse output; OPTIONAL Modbus OR M-Bus OR 4-20mA flow proportional outputs are also available. Please see the table below for an overview of the U1000MKII-FM models.
SKU | Title | Max. Pipe Size | Outputs | |||
---|---|---|---|---|---|---|
Volume Pulse | Modbus | M-Bus | 4-20mA | |||
804-11001400 | U1000MKII-FM Flow Meter with Pulse Output for 4" Pipes |
4" (22-115 OD/ 20-110 ID) |
Yes | No | No | No |
804-11004600 | U1000MKII-FM Flow Meter with Pulse Output for 6" Pipes |
6" (125-180 OD/ 105-165 ID) |
Yes | No | No | No |
804-11001401 | U1000MKII-FM Flow Meter with Pulse & 4-20mA Outputs for 4" Pipes |
4" (22-115 OD/ 20-110 ID) |
Yes | No | No | Yes |
804-11004601 | U1000MKII-FM Flow Meter with Pulse & 4-20mA Outputs for 6" Pipes |
6" (125-180 OD/ 105-165 ID) |
Yes | No | No | Yes |
804-11001402 | U1000MKII-FM Flow Meter with Pulse & Modbus Outputs for 4" Pipes |
4" (22-115 OD/ 20-110 ID) |
Yes | Yes | No | No |
804-11004602 | U1000MKII-FM Flow Meter with Pulse & Modbus Outputs for 6" Pipes |
6" (125-180 OD/ 105-165 ID) |
Yes | Yes | No | No |
804-11001403 | U1000MKII-FM Flow Meter with Pulse & M-Bus Outputs for 4" Pipes |
4" (22-115 OD/ 20-110 ID) |
Yes | No | Yes | No |
804-11004603 | U1000MKII-FM Flow Meter with Pulse & M-Bus Outputs for 6" Pipes |
6" (125-180 OD/ 105-165 ID) |
Yes | No | Yes | No |
The Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter can be used as a stand-alone meter or as part of an integrated management system.
It is simple to install as it has been factory configured and, therefore, requires minimal programming on-site. The user needs only adjust the guide rail and sensor assembly, connect the Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter to the power, and enter the inside diameter of the pipe and the pipe material. Moreover, clamp-on installation and transit-time ultrasonic technology enable non-invasive measurements, eliminating the need for mechanical parts to be inserted into the pipe and/or for the system to be drained or shut down.
The Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter functions by simultaneously transmitting ultrasound between the clamp-on transducers in both directions. When ultrasound is emitted in the direction of flow the speed of the sound is accelerated; when it is emitted in the opposite direction the speed of the sound is decelerated. The time difference between ultrasound emissions is directly proportional to flow velocity. Using the flow velocity and the pipe’s cross-sectional area, the operator can calculate the volumetric flow.
The Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter has a flow range of 0.1m/s to 10m/s (0.3ft/s to 32ft/s) and an accuracy of ±1% to ±3% (for 0.3m/s/ 1ft/s). Please see the video below for an overview of how to use the Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter.
Measurements are displayed on the Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter’s backlit LCD. Via this display, the user can also view installation and service information.
The Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter is a compact, cost-effective, and reliable alternative to traditional in-line meter installations. This rugged ultrasonic flow meter provides consistent performance in industrial environments.
Applications
Industries | Building Services |
Energy Management | |
Water Treatment | |
Chemical | |
Pharmaceutical | |
Petrochemical | |
Food | |
Recommended For | Hot water < 85°C (185°F) |
Chilled water | |
Potable water | |
Demineralised water | |
Chilled Water with Glycol | |
Applications/ Use | Hot water metering and flow measurement |
Flow measurement for heat metering | |
Chilled water metering and flow measurement | |
Flow measurement for chilled water energy metering | |
Potable water metering and flow measurement | |
Process water metering and flow measurement | |
Ultrapure water measurement |
Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter Key Features
- A permanent/ fixed clamp-on flow metering solution
- Utilises ultrasonic technology to measure flow rate and total flow from outside the pipe
- Volume pulse output
- OPTIONAL Modbus OR M-Bus OR 4-20mA flow proportional outputs available (see table above)
- OPTIONAL outputs are aM&T and BEM compatible
- Use as a stand-alone meter or as part of an integrated management system
- Simple-to-install: adjust the guide rail and sensor assembly, connect to the power, and enter the inside diameter of the pipe and the pipe material
- Factory configured: requires minimal site configuration
- Non-invasive measurement
- Simultaneously transmits ultrasound between the clamp-on transducers in both directions
- The time difference between the ultrasound transmissions is directionally proportional to the flow velocity
- Use the flow velocity and the pipe’s cross-sectional area to calculate the volumetric flow
- Flow range: 0.1m/s to 10m/s (0.3ft/s to 32ft/s)
- Accuracy: ±1% to ±3% (for 0.3m/s to 1ft/s)
- Backlit LCD
- Displays measurements and installation and service information
- Rugged: IP54
- Compact, cost-effective, and reliable alternative to traditional in-line meter installations
- Rugged ultrasonic flow meter provides consistent performance in industrial environments
What’s Included?
- Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter with Volume Pulse Output
- OPTIONAL Modbus OR M-Bus OR 4-20mA Flow Proportional Output
- 4” OR 6” Pipe Adapters
- Banding
- Acoustic Interface Gel
Micronics U1000MKII-FM Ultrasonic Fixed Clamp-on Flow Meter Technical Specifications
Measurement Technique | Ultrasonic transit time method for flow measurement. |
Turn Down Ratio | 200:1 |
Accuracy | +/- 1% – 3% of flow reading for >0.3m/s (1 ft/s) |
Flow Velocity Range | 0.1m/s – 10m/s (0.3 ft/s – 32 ft/s) |
Pipe Range |
Available in 2 options:
Note Pipe size is dependent on pipe material and internal diameter. |
Water Temp Range | 0°C – 85°C (32°F – 185°F) |
Pulse Output | Pulse or Frequency. |
Pulse for Volume flow and Alarms | |
Frequency for flow rate | |
The pulse output can be configured as a loss of signal or low flow alarm. | |
4-20mA Output | Optional 4-20mA flow proportional output |
Modbus Communication | Optional Modbus RTU slave, RS485 serial link hardware layer. Modbus connection cable is 1m. |
External Power Supply | 12V – 24V +/- 10% AC/DC at 7 watts per unit. Optional plug-in 12V power supply |
Electronics Enclosure | IP54 |
Input/Output Cable | 5m x 6 core for power in, 4-20mA and pulse out |
Dimensions | 250mm x 48mm x 90mm (10" x 2" x 4") (electronics + guide rail). |