The PF333 Portaflow range brings simplicity to the non-invasive measurement of liquid flow and hydronic energy. Portaflow offers the user quick and accurate flow and energy measurement with its easy-to-follow menu and simple setup. Results can be achieved within minutes of opening the case!
Compact, rugged, and reliable, the Portaflow range has been designed to provide sustained performance in industrial environments.
Micronics Portaflow PF333
The PF333 Portaflow electronics are housed in a specifically designed enclosure, which incorporates the graphic display, keypad, sensor, and output facility connections. Set-up of the unit is carried out by selecting the options displayed in the main menu and by following the simple instructions in any of the user-selectable languages.
The use of a rechargeable battery allows the unit to be operated for over 14 hours depending on the facilities used. Continuous operation via the PSU is also possible while recharging the battery. Battery status, signal strength, time and date, as well as flow and energy information, are all continuously displayed, keeping the user fully aware of the measurement process.
The Data Logger delivers 100,000,000 data points, 12 named sites, and the ability to download via USB to CSV file and export to Excel. It also logs application details, time, date, flow rate, forward total, reverse total, flow velocity, flow side temperature, return side temperature, temperature difference, power, total energy, signal Quality, signal SNR, and signal status.
How Does it Work?
The Portaflow 333 is a transit time ultrasonic flow meter designed to work with clamp-on transducers, to provide accurate measurement of liquid flowing within a closed pipe, without the need for any mechanical parts to be inserted through the pipe wall or to protrude into the flow system. It takes just a few minutes to install and there is no need to shut down flow or drain the system!
When ultrasound is transmitted between the transducers, its velocity is slightly increased when travelling in the direction of flow, and slightly reduced when travelling against the flow. The resulting transit time difference is directly proportional to the velocity of the flow in the pipe. Having measured the flow velocity and knowing the pipe cross-sectional area, the volumetric flow can be easily calculated.
Hydronic thermal energy, heat, or cooling load is calculated from a combination of the flow rate and the flow and return temperature difference or delta T to comply with EN1434 section 6.
Features
- Ultrasonic, cross-correlation flow measurement
- Reynolds number correction
- Easy to install
- Simple to follow set-up menu
- Sensor cables, blocks, and temp sensors, IP54 with IP68 option
- Flow Range - 0.1m/sec to 20m/sec bi-directional
- New cross-correlation flow measurement system
- Display - 64 x 240 pixels graphic display
- Set-up via 16 key control panel
- Battery or mains operation
- Rechargeable NiMH battery
- Battery Life - 14 hours 2.5 hours charge time, depending on load
- Power - 110 - 240VAC +/-10% supply via PSU
- 4 user-selectable languages including English, German, French, and Spanish
- Accuracy Pipe ID > 75mm - ±0.5% to ±2% of flow reading for flow rate >0.2m/s
- Accuracy Pipe ID 13-75mm - ±3% of flow reading for flow rate >0.2m/s
- CE approved
- Temperature sensors with PF333 energy meter
- Improved data logger logs energy and flows, all date-stamped
What's Included
- Portaflow unit Incorporating keypad and backlit display
- Power supply with UK/US/European adapters, 110/240VAC
- Output signal cable (current loop & 3 digital outputs)
- Transducer cables x 2, (2m)
- Chains x 2 (3.3m)
- Guide rails x 2 For use with A or B-type transducers
- Ultrasonic couplant
- Tape measure
- Transducer set 'A' for use on pipes 13mm to 115mm outside diameter.
Transducer set 'B' for use on pipes 50mm to 2000mm outside diameter.
(The Transducers received will depend on the configuration of the unit)
- Test block
- Syringe
- Ruled separation bar (two-piece)
- User manual
Product Range
- Micronics 780-6014 PF333 HM A - Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6014HT PF333 A HT Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6014HTM PF333 A HT / Magnetic Guiderails Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6014IP68 PF333 A IP68 Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6014IP68M PF333 A IP68 / Magnetic Guiderails Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6014M PF333 A Magnetic Guiderails Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6016 PF333 B Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6016HT PF333 B HT Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6016HTM PF333 B HT / Magnetic Guiderails Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6016IP68 PF333 B IP68 Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6016IP68M PF333 B IP68 / Magnetic Guiderails Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6016M PF333 B Magnetic Guiderails Portable Ultrasonic Liquid Flow/Heat Meter
- Micronics 780-6018 PF333 AB Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6018HT PF333 AB HT Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6018HTM PF333 AB HT / Magnetic Guiderails Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6018IP68 PF333 AB IP68 Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6018IP68M PF333 AB IP68 / Magnetic Guiderails Portable Ultrasonic Clamp-on Flow Meter
- Micronics 780-6018M PF333 AB Magnetic Guiderails Portable Ultrasonic Clamp-on Flow Meter