This kit includes the Metrel MI 3125BT Multifunction Tester and the A 2214 Ring Continuity Adaptor, please the 'What's Included?' section for full kit details.
Metrel MI3125BT Eurotest Combo Bluetooth Multifunction Tester
The Metrel MI3125BT Multifunction Tester is ideal for engineers who regularly perform extensive testing or work on TT and TN systems. It encompasses all crucial tests for installation safety and now offers the ability to test B-type (DC-sensitive) RCDs.
The Metrel MI3125BT Eurotest Combo Bluetooth Multifunction Tester incorporates the characteristics of fuses and RCDs (including EV types) to assess line/loop impedance results. Its bright, backlit graphic display ensures clarity of results, indications, measurement parameters, and messages. Additionally, the red and green LEDs on either side of the display provide a clear PASS/FAIL evaluation of test results.
Each test includes a help screen that guides you on connecting the instrument to the installation and performing the measurement. Results can be swiftly saved and referenced on the device, and later downloaded using the MESM software.
Key Features
- LED Pass/Fail indicators: two LED indicators for PASS / FAIL evaluation of test results are placed on both sides of the LCD
- Help screens: The instrument comes complete with built-in help screens for referencing on-site.
- Earth resistance measurement: The instrument performs 3-wire earth resistance testing with two additional rods.
- Built-in fuse tables: this unique feature allows automatic evaluation of the line/loop impedance compared to the regulations.
- Online voltage monitoring: monitors all 3 voltages in real-time.
- Upgradeable: if changes occur to the regulations, upgrades can be made to the firmware to keep the instrument up to date.
- Polarity swap: automatic polarity reversal on continuity test.
- Insulation range: wide range of insulation test voltages from 50 V to 1000 V, reading up to 1000 MΩ.
- Trip Lock function: The Zs (RCD) function performs a loop impedance test without tripping the RCD.
- Multi-system testing: tests on single and multiphase TT and TN systems.
- Built-in charger & rechargeable batteries: The unit has a built-in charging circuit and comes complete with a set of rechargeable NiMH batteries.
- RCD auto: The automated RCD testing procedure significantly reduces test time.
- B-type RCD testing is supported.
- BT connectivity: it enables BT communication with Android tablets and smartphones via built-in BT.
- PC SW Eurolink PRO included in the standard set enables the downloading of test results and parameters and the creation of test reports.
- Dimensions: 140 x 80 x 230 mm
- Mass: 1.0 kg
Metrel A 2214 Ring Continuity Adapter
The Metrel A 2214 Ring Continuity Adapter is designed for continuity measurements of ring final circuits. It automatically performs r1, rn, r2, and R1 + RN, R1 + R2 measurements.
The A 2214 connects swiftly to the colour-coded incoming and outgoing L, N, and PE wires at the distribution board. Controlled by the tester, it performs all necessary ring continuity tests. This efficient method greatly simplifies and shortens the time required for thorough testing of ring final circuits.
Key Features
- Automated continuity testing (patented) of ring final circuits: r1, rn, r2 and R1+RN, R1+R2.
- Live, neutral and PE resistance are all measured at a press of a button.
- Automatic calculation of (r1+rn)/4 and (r1+r2)/4 for easy results evaluation.
- Connected once, no need to change leads until all continuity tests are complete.
- Quick, efficient and easy. Optimize and significantly speed up (up to 60% or more) continuity tests of ring final circuits.
- Safety, no risk of forgotten connections.
- Convenience, no need to exchange leads or use connectors.
- Thoroughness, R1+RN also measured simultaneously.
- Test speed, connections made by the adapter.
- Accuracy, with the easy-null capability.
- Usability can be magnetically attached to the distribution board.
What's Included?
- Metrel MI 3125BT Eurotest Combo Bluetooth Multifunction Tester
- Metrel A 2214 Ring Continuity Adapter
- Soft hand strap
- Small soft carrying bag
- Test lead, 3 x 1.5 m
- Mains Plug Lead
- Tip Commander, 1.5m
- Test probe, 3 pcs (blue, brown, green)
- Crocodile clip, 3 pcs (blue, brown, green)
- Power supply adapter + 6 rechargeable batteries NiMH, type AA
- USB cable
- Metrel ES Manager BASIC license
- Metrel aMESM PRO Android app
- Short instruction manual
- Calibration certificate
- Small soft carrying bag A 1020 (A 2214)
- Crocodile clip A 1297, brown, 2 pieces (A 2214)
- Crocodile clip A 1309, green, 2 pieces (A 2214)
- Crocodile clip A 1310, blue, 2 pieces (A 2214)
- Battery A 1784, size AA, 1.5V alkaline, 4 pieces (A 2214)
- Instruction manual (A 2214)
Videos
A 2214 Ring Continuity Adapter Promotional
Metrel MI3125BT Eurotest Combo Bluetooth Multifunction Tester
Extra Features | AUTOSEQUENCES | PASS/FAIL System Evaluation | ✔ |
---|---|---|---|
Advanced User Interface | Graphical Help Menus | ✔ | |
SDK support | Upload structure | ✔ | |
Download | ✔ | ||
Main Features | Voltage AC | Frequency | ✔ |
Voltage TRMS | ✔ | ||
Three Phase | 3-Phase system (Phase SEQUENCE) | ✔ | |
Earth Bond / Continuity | Ring Test 200 mA (UK installations) | ✔ | |
Ring Auto 200 mA (UK installations) | ✔ | ||
Max Test Current 7 mA 2-wire | ✔ | ||
Max Test Current 200 mA 2-wire | ✔ | ||
Automatic polarity reversal | ✔ | ||
Insulation Resistance | Test Voltage 50 V | ✔ | |
Test Voltage 100 V | ✔ | ||
Test Voltage 250 V | ✔ | ||
Test Voltage 500 V | ✔ | ||
Test Voltage 1000 V | ✔ | ||
Automatic Discharge | ✔ | ||
Z Line / Loop Impedance | Zline L-L, L-N Ipsc - 3 Wire | ✔ | |
Zline L-L, L-N Ipsc - 2 Wire | ✔ | ||
Zloop L-PE, Ipfc - 3 Wire | ✔ | ||
Zloop L-PE, Ipfc - 2 Wire | ✔ | ||
Zs (rcd) - 3 Wire | ✔ | ||
Zref, ΔU% | ✔ | ||
Fuse Tables | ✔ | ||
RCD | RCD type AC | ✔ | |
RCD type A | ✔ | ||
RCD type F | ✔ | ||
RCD type B | ✔ | ||
RCD Uc | ✔ | ||
RCD (t) | ✔ | ||
10 mA | ✔ | ||
30 mA | ✔ | ||
100 mA | ✔ | ||
300 mA | ✔ | ||
500 mA | ✔ | ||
1000 mA | ✔ | ||
RCD I Ramp | ✔ | ||
RCD Auto | ✔ | ||
RCD 3-Phase | ✔ | ||
EV-RCD | ✔ | ||
MI-RCD | ✔ | ||
RCD-S (Selective) | ✔ | ||
Earth/Ground Resistance | Earth Resistance 3-wire | ✔ | |
EVSE measurements | Monitoring of voltage | ◉ | |
Monitoring of current | ◉ | ||
Simulation of external load | ◉ | ||
Additional Features | Hand-Held | Hand-Held | ✔ |
PASS / FAIL Indicators | PASS/FAIL Indicators | ✔ | |
Voltage Monitoring | Voltage Monitoring | ✔ | |
Display | LCD | ✔ | |
Back Light | ✔ | ||
Power Supply | Rechargeable Batteries in standard delivery | ✔ | |
Battery Powered | ✔ | ||
Power Supply 115 V (50-60Hz) | ✔ | ||
Power Supply 230 V (50-60Hz) | ✔ | ||
Mains Supply / PE Check | ✔ | ||
Test Lead Compensation | Test Lead Compensation | ✔ | |
Graphical user interface | Graphical Online Help | ✔ | |
Communication Port | Communication Port USB | ✔ | |
Communication Port RS232 - PS/2 | ✔ | ||
Built-in Bluetooth | Built-in Bluetooth | ✔ | |
Mobile Application | Android Application | ✔ | |
Printing / Scanning | QR-Code Printing / Scanning | ◉ | |
Memory | Internal memory | ✔ | |
Downloadable | ✔ | ||
Uploadable | ✔ | ||
IP protection | IP 40 | ✔ | |
Protection category | CAT IV 300 V | ✔ | |
CAT III 600 V | ✔ | ||
Special Accessories | Passive 3-Phase Adapter | Passive 3-Phase Adapter | ◉ |
Active Euro Checkbox | Active Euro Checkbox | ◉ | |
Active Ring Adapter EASYswitch | Active Ring Adapter EASYswitch (UK only) | ◉ | |
Tip Commander | Tip Commander | ◉ | |
Plug Commander | Plug Commander | ◉ | |
PC Software Package | PC Software Package | ✔ | |
MESM Compatible | ✔ | ||
Report creation | ◉ | ||
Professional reporting | ◉ | ||
Battery Charger | Battery Charger | ✔ | |
Medical Facilities | Patient recovery rooms and hospital wards | Public and workspace electrical safety in healthcare | ✔ |
Secondary power sources in healthcare | Field hospital | ✔ | |
Other applications | Preventative maintenance | Earth continuity and insulation testing | ✔ |
Line and loop impedance and RCD testing | ✔ | ||
Basic earth resistance | ✔ | ||
Voltage measurements | ✔ | ||
Current measurements | ✔ | ||
Frequency measurements | ✔ | ||
Troubleshooting | Installation Troubleshooting | ✔ | |
Standards Applied | Building LV Installation | EISinsp Competences: Low Voltage Electrical Installation Safety Inspection | ✔ |
EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers | ✔ | ||
IEC/EN 60364 Electrical Installations for Buildings series | ✔ | ||
IEC/EN 60364-6 Electrical Installations for Buildings - Verification | ✔ | ||
IEC/EN 60364-4-41 Electrical Installations for Buildings - Protection against electric shock | ✔ | ||
IEC/EN 60755 General safety requirements for residual current operated protective devices | ✔ | ||
IEC/EN 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) | ✔ | ||
IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series | ✔ | ||
IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements | ✔ | ||
IEC/EN 61557-2 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance | ✔ | ||
IEC/EN 61557-3 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance | ✔ | ||
IEC/EN 61557-6 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems | ✔ | ||
IEC/EN 61557-7 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence | ✔ | ||
IEC/EN 61557-10 Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures | ✔ | ||
VDE 0413 (IEC 61557) Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series | ✔ | ||
AS / NZ 3017 Electrical installations – Verification guidelines | ✔ | ||
AS / NZ 3018 Electrical installations - Domestic installations | ✔ | ||
BS 7671 IEE Wiring Regulations (18th edition) | ✔ | ||
CEI 64.8 V4 rated electrical equipment not exceeding 1,000 VAC and 1,500V DC | ✔ | ||
Earthing and lightning protection | LPSinsp Competences: Lightning Protection of Buildings Inspection | ✔ | |
LPSc Competences: Lightning Protection of Buildings for Contractors and Maintainers | ✔ | ||
IEC 62305 Protection against Lightning - series | ✔ | ||
IEC/EN 61557-5 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth | ✔ | ||
IEC/EN 61557-4 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding | ✔ | ||
Instrument safety towards the user | Directive EMC 89/336/EE on electromagnetic compatibility | ✔ | |
IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series | ✔ | ||
IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage | ✔ | ||
EMC safety | IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series | ✔ | |
Key | ✔ Supported | ◉ Optional |
Metrel A 2214 Ring Continuity Adapter
Main Features | Earth Bond / Continuity | Ring Test 200 mA (UK installations) | ✔ |
---|---|---|---|
Additional Features | Power Supply | Rechargeable Batteries in standard delivery | ✔ |
Battery Powered | ✔ | ||
Test Lead Compensation | Test Lead Compensation | ✔ | |
IP protection | IP 40 | ✔ | |
Other applications | Preventative maintenance | Testing ring final circuits | ✔ |
Standards Applied | Building LV Installation | BS 7671 IEE Wiring Regulations (18th edition) | ✔ |
Instrument safety towards the user | IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series | ✔ | |
EMC safety | IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series | ✔ | |
IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements | ✔ |
Reviews
SKU | RINGKIT1 |
---|---|
Manufacturer Part Code | RingKit1 |
Country of Origin | Slovenia |