The Metrel MI 3115 PV Analyser tests 1500 V photovoltaic systems in accordance with the IEC 62446 standard, supporting all category 1 and 2 tests and measurements.
It performs insulation resistance measurements of PV strings, I/U characteristic measurements, and converts measured values to STC values for comparison with nominal values provided by PV module manufacturers.
The device also measures irradiation and cell temperature in real time with a wireless remote unit, and allows users to perform all category 1 tests with a single touch of the start button.
Extra Features | Auto Tests | AUTO PV (Isc,Uoc, Ins+,Ins-) | ✔ | |
---|---|---|---|---|
AUTOSEQUENCES | AUTOSEQUENCE profile | ✔ | ||
AUTOSEQUENCE programmable | ✔ | |||
AUTOSEQUENCE PV | ✔ | |||
PASS/FAIL System Evaluation | ✔ | |||
On-site Parameter Settings | ✔ | |||
Automatic Test Sequences | Multitest sequence | ✔ | ||
Advanced User Interface | Colour display | ✔ | ||
Touch screen | ✔ | |||
Graphical Help Menus | ✔ | |||
Database System Built-In | ✔ | |||
SDK Support | Upload structure | ✔ | ||
Upload measurements | ✔ | |||
Download | ✔ | |||
Main Features | Voltage DC | Voltage DC | ✔ | |
DC 1750 V | ✔ | |||
Current DC | Current DC | ✔ | ||
DC 20 A | ✔ | |||
Earth Bond / Continuity | Max Test Current 200 mA 2-wire | ✔ | ||
Insulation Resistance | Test Voltage 250 V | ✔ | ||
Test Voltage 500 V | ✔ | |||
Test Voltage 1000 V | ✔ | |||
Test Voltage 1500 V | ✔ | |||
Max resistance range 200 MOhm | ✔ | |||
PV Module/String | ✔ | |||
PV | Isc, Uoc, Polarity | ✔ | ||
PV Insulation | ✔ | |||
I-V Curve/STC Irradiance | ✔ | |||
I-V Curve/STC Module Temperature | ✔ | |||
I-V Curve/STC I-V Curve | ✔ | |||
I-V Curve/STC Extrapolation to STC | ✔ | |||
I-V Curve/STC Umpp, Impp, Pmax | ✔ | |||
I-V Curve/STC Module DB | ✔ | |||
I-V Curve/STC Rs (Calculated in PC SW) | ✔ | |||
DC side measurements U | ✔ | |||
DC side measurements I | ✔ | |||
DC side measurements P | ✔ | |||
Power Measurements | Power for I/U curve in PV | ✔ | ||
Additional Features | Security | User Accounts | ✔ | |
PASS / FAIL Indicators | PASS/FAIL Indicators | ✔ | ||
Voltage Monitoring | Voltage Monitoring | ✔ | ||
Display | LCD | ✔ | ||
Back Light | ✔ | |||
Keyboard | Virtual Keyboard | ✔ | ||
Power Supply | Rechargeable Batteries in standard delivery | ✔ | ||
Battery Powered | ✔ | |||
Dual Power | ✔ | |||
Power Supply 115 V (50-60Hz) | ✔ | |||
Power Supply 230 V (50-60Hz) | ✔ | |||
Test Lead Compensation | Test Lead Compensation | ✔ | ||
Graphical User Interface | Graphical online Help | ✔ | ||
Remote Communication | Remotely controlled | ✔ | ||
Black-Box Communication Protocol | ✔ | |||
3G / WiFi remote communication | ✔ | |||
Communication Port | Communication Port USB | ✔ | ||
Communication Port RS232 - PS/2 | ✔ | |||
Built-in Bluetooth | Built-in Bluetooth | ✔ | ||
Memory | Internal memory | ✔ | ||
microSD memory card | ✔ | |||
Downloadable | ✔ | |||
Uploadable | ✔ | |||
IP Protection | IP 40 | ✔ | ||
IP 54 | ✔ | |||
Protection Category | CAT II 300 V | ✔ | ||
High Altitude Protection Category | 4000 m | ✔ | ||
Special Accessories | ||||
PV Reference Cell | PV Pyranometer / Reference Cell | ✔ | ||
PV Remote Logger | PV Remote Logger | ✔ | ||
Temperature Probe | Temperature Probe | ✔ | ||
PC Software Package | PC Software Package | ✔ | ||
Report creation | ✔ | |||
Professional reporting | ◯ | |||
Battery Charger | Battery Charger | ✔ | ||
Electrical Energetics | Renewable Energy Sources | STC values and performance of PV panels | ✔ | |
Building Facilities | Special Locations | Low-voltage photovoltaic installations | ✔ | |
Standards Applied | Building LV Installation | EISinsp Competences: Low Voltage Electrical Installation Safety Inspection | ✔ | |
EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers | ✔ | |||
IEC/EN 60364 Electrical Installations for Buildings series | ✔ | |||
IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series | ✔ | |||
Photovoltaic Systems | IEC/EN 62446 Photovoltaic (PV) systems - Requirements for testing, documentation and maintenance | ✔ | ||
EN 62466-1 Photovoltaic (PV) systems. Requirements for testing, documentation and maintenance – Part 1: Grid-connected systems – Documentation, commissioning tests and inspection | ✔ | |||
EN 62466-2 Photovoltaic (PV) systems. Requirements for testing, documentation and maintenance – Part 2: Grid-connected systems – Maintenance of PV systems | ✔ | |||
Instrument Safety Towards User | IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements | ✔ | ||
IEC/EN 61010-031 Amendment 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement | ✔ | |||
IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits | ✔ | |||
EMC Safety | IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements | ✔ | ||
Key | ✔ Supported ✘ Not Supported ◯ Optional |
SKU | MI3115 |
---|---|
Manufacturer Part Code | MI3115 ST |
Country of Origin | Slovenia |