All Metrel Products

Metrel MI 3152 Multifunction Tester & A1532 EVSE Adapter Kit 2

SKU
EVKIT2
Rating:
0%
(0)
Reward Points
:
1574
£1,888.80 £1,574.00
Lead Time: 1-6 Days
Free UK Delivery*
Choose a Special Offer
  • 50M R2 Extension Wander Test Lead (PVC Cable Reel)
    50M R2 Extension Wander Test Lead (PVC Cable Reel)
    FREE
    £49.00
  • 50M R2 Extension Wander Test Lead (PVC Cable Reel) SKU: (TSTL50M)
    FREE
    £49.00
    50M R2 Extension Wander Test Lead (PVC Cable Reel)
    • Extra long test lead
    • Suitable for MFTs and installation testers
    • Crocodile clip connector
  • Lockout Starter Kit facing right
    Lockout Starter Kit - Incl. Hasps, Padlocks, Tags, MCB Lockout & More
    FREE
    £25.00
  • Lockout Starter Kit - Incl. Hasps, Padlocks, Tags, MCB Lockout & More SKU: (LT-LPP)
    FREE
    £25.00
    Lockout Starter Kit facing right
    • Basic lockout/tagout kit
    • Comes with hasps, ties, padlocks and more
    • Supplied in useful carrying pouch
  • CK Tools T3943 Automatic Wire Stripper Pro facing left
    CK Tools T3943 Automatic Wire Stripper Pro
    FREE
    £36.50
  • CK Tools T3943 Automatic Wire Stripper Pro SKU: (T3943)
    FREE
    £36.50
    CK Tools T3943 Automatic Wire Stripper Pro facing left
    • Replaceable stainless steel cutting blade
    • Suitable for copper/aluminium wire 0.05 - 8.5mm
    • Micro adjustment knob
  • TestSafe Fibreglass Fish Tape – 30m (Orange)
    TestSafe Fibreglass Fish Tape Cable Puller – 30m
    FREE
    £24.99
  • TestSafe Fibreglass Fish Tape Cable Puller – 30m SKU: (TS-FG-FT-30M)
    FREE
    £24.99
    TestSafe Fibreglass Fish Tape – 30m (Orange)
    • 30m fibreglass cable
    • Impact-resistant, textured plastic case
    • Large, durable, non-slip handle with fingertip grooves
  • Evik Cable Pulling Fibreglass Rods – Standard Kit with Tube
    Evik 10 Piece Cable Pulling Fibreglass Rods, Standard Kit in Tube
    FREE
    £39.00
  • Evik 10 Piece Cable Pulling Fibreglass Rods, Standard Kit in Tube SKU: (EV-STD-KIT-T)
    FREE
    £39.00
    Evik Cable Pulling Fibreglass Rods – Standard Kit with Tube
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Free Electrician's Accessory
Metrel MI 3152 Multifunction Tester & A1532 EVSE Adapter Kit 2

This Entry Set kit includes the Metrel MI 3152 Multifunction Tester and the A 1532 EVSE Adaptor, please the 'What's Included?' section for full kit details.

Metrel MI 3152 Multifunction Tester

The Metrel MI 3152 EurotestXC Multifunction Tester is part of the latest generation of Metrel’s multifunctional measuring instruments. It maintains familiar features like comprehensive installation safety testing per IEC/EN 61557 standards and AUTO SEQUENCE testing for TN, TT, and IT earthing systems, all controlled via a new user interface with a large colour touch screen display.

The device provides a wide array of functions, such as online voltage monitoring, phase sequence testing, earth resistance measurement, illuminance measurement, and TRMS current measurement. It also conducts RCD tests, line and loop impedance tests, earth resistance measurements, ISFL measurements, and IMD tests.

Key Features

  • Predefined Automatic tests:
    • Auto TT (U, Zln, Zs, Uc);
    • Auto TN/RCD (U, Zln, Zs, Rpe)
    • Auto TN (U, Zln, Zlpe, Rpe)
    • Auto IT (U, Zln, Isc, Isfl, IMD)
  • Built-in help screens for referencing on site.
  • Built-in fuse tables for automatic evaluation of the line/loop impedance result.
  • Monitoring of all 3 voltages in real-time.
  • Automatic polarity reversal on continuity test.
  • Automated RCD testing procedure.
  • Built-in charger and rechargeable batteries as standard accessory.
  • BT communication with PC, Android tablets and smartphones via built-in BT.
  • PC SW Metrel ES Manager for creation of test structures and uploading, downloading of test results and report creation.
  • Support for aMESM Android APP and data management tool (option).
  • Dimensions (w x h x l): 230 x 103 x 115 mm.
  • Mass (without accessories): 1.3 kg.

Metrel A 1532 EVSE Adaptor

The Metrel A 1532 EVSE Adapter is a specialized tool for testing Mode 3 electric vehicle supply equipment with a type 2 connector.

Key Features

  • Banana socket outputs for connection to a 3-phase installation tester.
  • Voltage indicators on EVSE output.
  • Proximity Pilot resistance selector for simulation of EV cable presence and current rating detection.
  • Control Pilot resistance selector for simulation of electric vehicle status.
  • Socket output for connection to a 1-phase installation tester (Phase 1, Neutral, PE).
  • Type 2 Male Plug connector for connection to EVSE.
  • 6 mA EV RCD support.
  • MESM report creation.
  • Dimensions (w x h x l): 200 x 100 x 70 mm
  • Mass (without accessories): 0.82 kg

What's Included?

  • Metrel MI 3152 Multifunction Tester
  • Metrel A1532 EVSE Adapter
  • Test lead, 3 x 1.5 m
  • Power supply adapter
  • 6 NiMH rechargeable batteries, type AA
  • Test probe, 3 pcs (blue, brown, green)
  • Crocodile clip, 3 pcs (blue, brown, green)
  • RS232 - PS/2 cable
  • USB cable
  • Soft carrying bag
  • Soft carrying neck belt
  • Short instruction manual
  • Instruction manual on CD
  • Handbook on CD
  • Calibration certificate
  • Small, Soft Carrying Bag for A1532
  • Instruction Manual for A1532

Videos

MI 3152 Multifunction Tester Promotional

Electrical Installation Testing | MI 3152 EurotestXC | Features Overview

A1532 EVSE Adapter Part 1 - Overview

Electric Vehicle Supply Equipment | A 1532 EVSE adapter | Testing 1

A1532 EVSE Adapter Part 2 - Testing Procedure

Electric Vehicle Supply Equipment | A 1532 EVSE adapter | Testing 2

Free Electrician's Accessory
  • 50M R2 Extension Wander Test Lead (PVC Cable Reel) - TSTL50M, typically £49.00
  • Lockout Starter Kit - Incl. Hasps, Padlocks, Tags, MCB Lockout & More - LT-LPP, typically £25.00
  • CK Tools T3943 Automatic Wire Stripper Pro - T3943, typically £36.50
  • TestSafe Fibreglass Fish Tape Cable Puller – 30m - TS-FG-FT-30M, typically £24.99
  • Evik 10 Piece Cable Pulling Fibreglass Rods, Standard Kit in Tube - EV-STD-KIT-T, typically £39.00

Metrel MI 3152 Multifunction Tester

Extra Features Workspaces El. LV Installation Safety Modes
Industrial Mode
Medical Mode
EVSE Mode
IT Vehicles / Mobile Units Mode
Lightning Mode
Project Structure
Visual Inspection Mode
Functional Inspection Mode
Auto Tests AUTO TT (U, Zln, Zs, Uc)
AUTO TN/RCD (U, Zln, Zs, Rpe)
AUTO TN (U, Zln, Zlpe, Rpe)
AUTO IT (U, Zln, Isc, Isfl, IMD)
Auto Test Line/Loop Impedance TN/TT
AUTOSEQUENCES AUTOSEQUENCE profile
AUTOSEQUENCE EVSE
AUTOSEQUENCE Barcode testing
PASS/FAIL System Evaluation
On-site Parameter Settings
Automatic test sequences Multitest sequence
Advanced User Interface Colour display
Touch screen
Adaptable user interface
Graphical Help Menus
Database System Built-In
Programmable Memory Structure
Multi-level Memory Organiser
SDK support Upload structure
Upload measurements
Download
Main Features
Voltage AC Frequency
Voltage TRMS
Three Phase 3-Phase system (Phase SEQUENCE)
Differential leakage current
Earth Bond / Continuity PE lead resistance 200 mA 3-wire
Ring Test 200 mA (UK installations)
Ring Auto 200 mA (UK installations)
Max Test Current 7 mA 2-wire
Max Test Current 200 mA 2-wire
Automatic polarity reversal
Insulation Resistance Test Voltage 50 V
Test Voltage 100 V
Test Voltage 250 V
Test Voltage 500 V
Test Voltage 1000 V
Test of IMD
Test of ELM
DC Ramp Voltage Test/Varistor test
Automatic Discharge
Leakage Current Differential Leakage
Leakage Current (with optional Clamp)
ISFL: L1, L2 (First Fault Leakage)
AC Insulation Leakage
Z Line / Loop Impedance Zline L-L, L-N Ipsc - 3 Wire
Zline L-L, L-N Ipsc - 2 Wire
Zloop L-PE, Ipfc - 3 Wire
Zloop L-PE, Ipfc - 2 Wire
Zs (rcd) - 3 Wire
Zref, ΔU%
Fuse Tables
Max. Ipfc = 20kA
RCD RCD type AC
RCD type A
RCD type F
RCD type B
RCD type B+
RCD Uc
RCD (t)
10 mA
30 mA
100 mA
300 mA
500 mA
1000 mA
RCD I Ramp
RCD Auto
RCD 3-Phase
EV-RCD
MI-RCD
RCD-S (Selective)
PRCD PRCD-S, PRCD-K
Earth (Electric) Leakage Relay
Earth/Ground Resistance Earth Resistance 2-wire
Earth Resistance 3-wire
Wenner 4-wire Specific Earth Resistance
Two Iron Clamps Earth Resistance
Functional test and troubleshooting Load test
Power Measurements Active power
Reactive power
Apparent power
Power factor
Harmonics Analysis THD current
THD voltage
Current harmonics
Voltage harmonics
EVSE measurements Monitoring of voltage
Monitoring of current
Simulation of external load
Additional Features Cable location Cable location
Hand-Held Hand-Held
Security User Accounts
PASS / FAIL Indicators PASS/FAIL Indicators
Voltage Monitoring Voltage Monitoring
Display LCD
Back Light
Keyboard QWERTY Keyboard
Virtual Keyboard
Power Supply Rechargeable Batteries in standard delivery
Battery Powered
Power Supply 115 V (50-60Hz)
Power Supply 230 V (50-60Hz)
Mains Supply / PE Check
Test Lead Compensation Test Lead Compensation
Buzzer Buzzer
Graphical user interface Graphical Online Help
Communication Port Communication Port USB
Communication Port RS232 - PS/2
Built-in Bluetooth Built-in Bluetooth
Mobile Application Android Application
Printing / Scanning QR-Code Printing / Scanning
Memory Internal memory
microSD memory card
Downloadable
Uploadable
IP protection IP 40
Protection category CAT IV 300 V
CAT III 600 V
Special Accessories EVSE adapter A 1832 Mode 3 Charging cable adapter
Passive 3-Phase Adapter Passive 3-Phase Adapter
Active Impedance Adapter Active Impedance Adapter
Adapter for specific resistance ρ ρ adapter
Active Euro Checkbox Active Euro Checkbox
Active Ring Adapter EASYswitch Active Ring Adapter EASYswitch (UK only)
Cable Locator Cable Locator
Tip Commander Tip Commander
Plug Commander Plug Commander
Current clamps DC - Current Clamp
Generator Current Clamp
AC Leakage Current Clamp
Lux Sensor Lux Sensor
Smartphones scanner Smartphones scanner
PC Software Package PC Software Package
MESM Compatible
Report creation
Professional reporting
Battery Charger Battery Charger
Electrical Energetics Power generation Earthing and lightning protection in thermal energy power plants
Renewable energy sources Generator stator testing
Lightning protection testing in wind plants
Two-clamp method for measuring earth loops in a solar plant
Power distribution Insulation of long cables
Industrial installations Remote antenna tower earthing resistance
Specific earth resistance measurement methods
Building Facilities Low voltage electrical installation safety Substation electrical safety
Mains bonding and touch voltages during fault
Switchboards and automatic trip-out protection
Public places electrical safety
Low voltage earthing and lightning protection Earthing measurement with fall of potential method
2-clamps method for measuring lightning and earth protection
Surge protection devices
Special locations Wet and outdoor locations
IT system
DC installations
EVSE construction and testing
Transportation e-Mobility EVSE domestic installation testing
EVSE periodic inspection
Renewable power and car charging
Mobile installations Vehicles with an on-board generator
Emergency response vehicles
Telecommunication equipment in mobile installations
Medical Facilities Hospital earthing and lightning protection Two clamps method for measuring lightning and earth protection
Hospital earthing measurement with fall of potential method
Mains bonding and touch voltages during fault current
Surge protection devices in hospitals
Power supply and power distribution Hospital switchboards and automatic trip-out protection
Surgery rooms or operating theatres Medical IT system
Isolated areas RCDs
Patient recovery rooms and hospital wards Public and workspace electrical safety in healthcare
Electrical safety in hospital wet areas
Secondary power sources in healthcare Generator safety
Ambulances
Field hospital
Standards Applied Building LV Installation EISinsp Competences: Low Voltage Electrical Installation Safety Inspection
EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers
IEC/EN 60364 Electrical Installations for Buildings series
IEC/EN 60364-6 Electrical Installations for Buildings - Verification
IEC/EN 60364-4-41 Electrical Installations for Buildings - Protection against electric shock
IEC/EN 60755 General safety requirements for residual current operated protective devices
IEC/EN 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs)
IEC/EN 61009 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs)
IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
IEC/EN 61557-2 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
IEC/EN 61557-3 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance
IEC/EN 61557-6 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
IEC/EN 61557-7 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
IEC/EN 61557-10 Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures
VDE 0413 (IEC 61557) Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
AS / NZ 3017 Electrical installations – Verification guidelines
AS / NZ 3018 Electrical installations - Domestic installations
BS 7671 IEE Wiring Regulations (18th edition)
CEI 64.8 V4 rated electrical equipment not exceeding 1,000 VAC and 1,500V DC
Earthing and lightning protection LPSinsp Competences: Lightning Protection of Buildings Inspection
LPSc Competences: Lightning Protection of Buildings for Contractors and Maintainers
IEC 62305 Protection against Lightning - series
IEC/EN 61557-5 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth
IEC/EN 61557-4 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding
Power quality PQA Competences: Power Quality Analyzing & Reporting
IEC/EN 61557-12 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 12: Power metering and monitoring devices (PMD)
Electrical switchboards safety ESB Competences: Electrical Switchboard Safety Testing
IEC/EN 62271 High-voltage switchgear and controlgear - series
IEC/EN 62271-1 High-voltage switchgear and control gear - Part 1: Common specifications for alternating current switchgear and control gear
IEC/EN 62271-100 High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers
Mobile Units Electrical Safety eMOB Competences: Electrical LV Installations in Mobile Units Safety
IEC/EN/HD 60364-7-717 Low-voltage electrical installations: Requirements for special installations or locations – Supplies for Electrical Vehicles
ISO 6469-3 - Electrically propelled road vehicles Safety specification Part 3: Electrical safety
Electrical Vehicle Supply Equipment EVSE Competences: Electrical Vehicle Supply Equipment Safety
IEC/EN 61851 Electric vehicle conductive charging system
IEC/EN 62752 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
Medical electrical equipment AS/NZS 3551 Management programs for medical devices
Medical and surgery room installations MEDi Competences: Medical and Surgery Rooms Electrical Installations Safety
Instrument safety towards the user Directive EMC 89/336/EE on electromagnetic compatibility
IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series
IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
EMC safety IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series
Key ✔ Supported | ◉ Optional

A 1532 EVSE Adaptor

Extra Features Workspaces EVSE Mode
AUTOSEQUENCES AUTOSEQUENCE EVSE
Main Features EVSE measurements Proximity pilot 0-64 A
Control Pilot states settings
Line impedance for charging station
Fault loop impedance for charging station
Functional test of proximity pilot
Functional test of control pilot
Isolation test for charging station
1-phase charging station testing
1-phase test through socket
3-phase charging station testing
CP short error simulation (E state)
Additional Features IP protection IP 40
Protection category CAT II 300 V
Building Facilities Special locations EVSE construction and testing
Transportation e-Mobility EVSE domestic installation testing
EVSE periodic inspection
Renewable power and car charging
Mobile installations Vehicles with an on-board generator
Standards Applied Building LV Installation EISinsp Competences: Low Voltage Electrical Installation Safety Inspection
EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers
IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
Mobile Units Electrical Safety ISO 6469-3 - Electrically propelled road vehicles Safety specification Part 3: Electrical safety
Electrical Vehicle Supply Equipment EVSE Competences: Electrical Vehicle Supply Equipment Safety
Accessories related to this product:
Metrel A1532 EVSE Adapter for Electric Vehicle Charger Testing - Datasheet Datasheets Metrel MI3152 EurotestXC Multifunction Installation Tester - Datasheet Datasheets Metrel MI3152 EurotestXC Multifunction Installation Tester - User Manual Manuals & Guides Metrel A1532 EVSE Adapter for Electric Vehicle Charger Testing - User Manual Manuals & Guides Metrel A1532 EVSE Adapter for Electric Vehicle Charger Testing - Brochure Brochures & Catalogues Metrel MI3152 EurotestXC Multifunction Installation Tester - Brochure Brochures & Catalogues

Reviews

Additional Information
SKU EVKIT2
Manufacturer Part Code EVKIT2
Country of Origin Slovenia