Megger VF6 EX Hazardous Area AC Voltage Detector

Hazardous area (Ex) rated for use on gas platforms and other petrochemical environments, the Megger VF6 Ex Hazardous Area AC Voltage Detector is a non-contact voltage tester capable of identifying AC voltages between 12V and 1000V. It has two voltage ranges: Low (12-1000V AC) and Medium (100V – 1000V AC). A bright-red LED, audible alarm, and vibration warning alert the user when an AC voltage has been detected. The Megger VF6 Ex Hazardous Area AC Voltage Detector also features an integrated LED torch and is housed in a durable, rubber, over-moulded casing with a screw-on battery cover. It has a CAT IV 1000V safety rating and an ingress protection rating of IP67.

The Megger VF6 Ex Hazardous Area AC Voltage Detector is a rugged and reliable AC voltage indicator suitable for detecting AC voltages at socket outlets, switches, circuit breakers, fuses, cables, and luminaires. It can also identify live conductors, find a break in a conductor, and verify a blown fuse in a circuit.

Megger VF6 Ex Hazardous Area AC Voltage Detector Key Features

  • A non-contact AC voltage detector
  • Hazardous area (Ex) rated for use on gas platforms and other petrochemical environments
  • Range: 12V to 1000V AC
  • Low Voltage range: 12-1000V AC
  • Medium Voltage range: 100V-1000V AC
  • Bright red LED alert
  • Audible alert
  • Vibration alert
  • Integrated LED torch
  • Durable, rubber, over-moulded casing
  • Screw-on battery cover
  • Safety rating: CAT IV 1000V
  • IP67
  • Detect AC voltages at socket outlets, switches, circuit breakers, fuses, cables, and luminaires
  • Identify live conductors
  • Find a break in a conductor
  • Verify a blown fuse in a circuit
  • A rugged and reliable AC voltage indicator

What’s Included?

  • Megger VF6 Ex Hazardous Area AC Voltage Detector 
  • 2x AAA Batteries

Megger VF6 EX Hazardous Area AC Voltage Detector Technical Specifications 

Detection voltage Range 12 V AC to 1000 V AC, 100 V to 1000 V AC
Frequency Range 50/60 Hz
Batteries 2 x AAA / LR03 1.5 V batteries
Ambient Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -10 °C to 60 °C (14 °F to 140 °F)
Humidity 80 % max
Altitude 2000 metres
Pollution Degree 2
Safety Compliance CAT IV 1000 V
Auto Power Off 5 minutes
Ingress Protection Rating IP67
Conforms to Certificate Number II 2 G Ex ib op is IIB T4 Gb
Presafe 17 ATEX 9668X
Megger VF6 EX Hazardous Area AC Voltage Detector - Datasheet Datasheets

Reviews

Additional Information
SKU MEGVF6
Manufacturer Part Code 1013-097
Country of Origin China