FREE - PASS The Complete Guide to EET (PAT) Testing, 5th Edition
Buy a PAT testing kit and get an updated PAT Testing Guide worth £24.99. This 129 page indepth PAT testing book is a great addition to your kit. View PAT Guide
Megger PAT450 PAT Tester - PAT Elite Kit - Kit 4
Our best Megger PAT450 bundle pack, this exclusive kit comes with absolutely everything a PAT tester needs. The kit is packed full of accessories, including labels, a printer, and cartridge, a barcode scanner, an eLearning PAT Testing Course including an exam and certificate, adapters, a microwave leakage detector, and much more!
Megger's most advanced PAT tester, the PAT450 can perform every test ranging from insulation to flash testing. The PAT450 includes fully downloadable internal memory and can store up to 10000 individual records directly on the tester. For easy management of your data, just connect the tester to a PC and use the included software to interact with testing data, or use the included printer and barcode scanner to speed up your testing.
Key Features
- Downloadable - 10000 record memory
- Large-size 5.7" VGA backlit full-colour screen
- Flash testing at 1.5kV and 3kV
- 200mA, 10A, and 25A bond test with high-duty cycle (ideal for repetitive testing)
- Configurable - set your PASS/FAIL limits and adjust testing times
- Can be used with an optional barcode scanner and printer (saves time typing asset IDs)
- 230V and 110V operation allows the unit to be used in both commercial and residential applications
- Integrated QWERTY keyboard for text entry
- Supply measurement function
- Insulation testing at 250V and 500V
- Alternative leakage testing - substitute, differential, and touch current
- Operation test with VA measurements
- Extension lead tests - earth bond, insulation, polarity, and portable RCD
- Automatic and manual testing routines
- Compatible with Megger's PowerSuite software (sold separately)
What's In The Kit?
- Megger PAT450 Downloadable PAT Tester
- Printed Quick Start Guide
- Complete User Guide on CD
- Calibration Certificate
- Continuity/Earth Bond Lead + Probe
- Extension Lead Adaptor (13A)
- Carry Case w/ Lead/Document Pouch
- Plug Adaptor IEC C6 - C13 (3 Way 5A PSU)
- Flash Lead (3.0kV, 3.5mA)
Also includes:
- UNI-T UT07A Socket Tester
- CK Tools AV05050 5 Piece Insulated Screwdriver Set
- eLearning PAT Testing Course - Includes Exam and Certificate
- Microwave Leakage Detector
- 3 x IEC Adapter Set
- 2 x 110V Adapter Set
- 500 x Passed PAT Testing Labels
- 500 x Circular Passed PAT Testing Labels
- 500 x Cable Wrap PAT Labels
- 500 x Failed PAT Labels
- Visual Inspection Labels
- SimplyPats PAT Testing Software
- Barcode Scanner
- 1000 x Barcode Labels
- Brother Printer (NEW for this kit)
- Printer Cartridge (NEW for this kit)
This table breaks down exactly what's included in this kit, plus our other PAT450 bundle packs.
Item | PAT Essentials Kit (Bundle 1) | PAT Business Kit (Bundle 2) |
PAT Premium Kit (Bundle 3) | PAT Elite Printer Kit (Bundle 4) |
---|---|---|---|---|
UNI-T UT07A Socket Tester Need to check if your sockets are working right? Just plug this into a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
Yes | Yes | Yes | Yes |
CK Tools AV05050 Screwdriver Set This bundle pack includes a set of 5 fully insulated electrical screwdrivers which are suitable for live electrical work to 1000V. |
Yes | Yes | Yes | Yes |
eLearning PAT Testing Course - Includes Exam and Certificate Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
Yes | Yes | Yes | Yes |
Microwave Leakage Detector It's common practice to check microwave radiation levels while you're PAT testing - use this portable, easy-to-use microwave leakage detector to do so. |
Yes | Yes | Yes | Yes |
IEC Adapter Set A special bundle pack with three IEC adapters, allows you to use your PAT tester with various types of IEC cables and power supplies. |
Yes | Yes | Yes | Yes |
110V Adapter Set Use these two 110V connector leads to connect your PAT tester to 110V equipment commonly found on construction sites and similar applications. |
Yes | Yes | Yes | Yes |
Passed PAT Testing Labels A PAT essential! We include two 500-label rolls in your purchase, ensuring you have everything you need for labelling appliances after testing. |
Yes, 1000x | Yes, 1000x | Yes, 1000x | Yes, 500x |
1000 x Circular Passed PAT Labels Uniquely designed passed PAT testing labels with circular design - ideal for smaller plugs or appliances where you can't easily fit other labels. |
Yes, 500x | Yes, 1000x | Yes, 1000x | Yes, 500x |
500 x PAT Testing Cable Wrap Labels These labels wrap around cables and are great for labelling appliance power leads where you can't fix a suitable label. |
Yes, 500x | Yes, 500x | Yes, 500x | Yes, 500x |
500 x Failed PAT Testing Labels You won't need these very often, but if an appliance ever fails testing you should place one of these labels and take it out of use for repair or replacement. |
Yes, 500x | Yes, 500x | Yes, 500x | Yes, 500x |
Visual Inspection Labels You should check your appliances for obvious signs of damage before testing. Look for frayed wires, loose connections, and damaged plugs, then place one of these labels on if the appliance passes. |
No | Yes | Yes | Yes |
SimplyPats PAT Testing Software Use SimplePats PAT Testing Software alongside your PAT tester to download your results to a PC and keep a database of all of your findings. |
No | Yes | Yes | Yes |
Barcode Scanner This Bluetooth/USB barcode scanner is great for speeding up your record-keeping by using your Megger PAT tester and barcode labels. |
No | No | Yes | Yes |
Barcode Labels Pair these up with your Bluetooth barcode scanner and quickly recall your previous records, or make new records, using your Apollo series PAT tester. |
No | No | Yes, 2000x | Yes, 1000x |
Brother Printer and Printer Cartridge Create customised labels when out testing with this portable printer and cartridge pack! |
No | No | No | Yes |
- PASS The Complete Guide to EET (PAT) Testing, 5th Edition - PASS-PAT-HB, typically £24.99
Megger PAT450 Technical Specifications
Electrical Supply Range | 230V ±10 @ 50/60Hz 110V ± 10% + 110V ±10% @50Hz |
Bond Test (10A and 25A) | |
Open Circuit Voltage | 9V AC ±10% ± 0.1V (supply: 230V 50Hz) |
Earth Bond Resistance Accuracy | ±5% ± 3 digits (0 to 0.49Ω) ±5% ±5 (0.5 to 0.99Ω) |
Display Range | 0 to 1.99Ω |
Continuity Test (200mA) | |
Continuity Test Voltage | 9V AC ± 10% ± 0.1V (supply: 230V 50Hz) |
Continuity Resistance Accuracy | ±5% ± 3 digits (0 to 0.49Ω) ±5% ± 5 digits (0.5 to 0.99Ω) |
Continuity Resistance Resolution | 10mΩ (1 to 19.99Ω) |
Display Range | 0 to 19.99Ω |
Insulation Test (250V and 500V) | |
Insulation Resistance Accuracy (230V) | ±2% ±5 digits (0 to 19.99MΩ) ±5% ± 10 digits (20 to 99.99MΩ) |
Insulation Resistance Resolution | 0.01MΩ |
Display Range | 0 to 99.99MΩ |
Substitute Leakage Test | |
Test Voltage and Frequency | 40V AC ±10% nominal mains frequency |
Leakage Current Accuracy | ±5% ± 5 digits |
Leakage Current Resolution | 0.01mA |
Display Range | 0 to 19.99mA |
Differential Leakage Current | |
Test Voltage | Nominal mains 110/230V AC |
Test Frequency | Nominal mains 50/60Hz |
Differential Leakage Current Accuracy | ±5% ± 0.05mA (1.0mA to 9.99mA) ±5% ± 0.1mA (0.1mA to 0.99mA) |
Resolution | 0.01mA |
Display/Measurement Range | 0.10mA to 19.99mA |
Test Duration | User-selectable from 1 sec 10 sec to infinity |
Touch Current Test | |
Test Voltage and Frequency | Nominal mains supply |
Touch Current Accuracy | ±5% ± 5 digits |
Touch Current Resolution | 0.01mA |
Display | 0 to 10mA |
Operational Test | |
Test Voltage and Frequency | Nominal mains supply |
VA Rating | 230V 3700VA 110V 1800VA |
VA Accuracy | ±5% ± 10 digits (0 to 99VA) ±5% ± 50 digits (100VA to 999VA) ±5% ± 100 digits (1000VA to 3700VA) |
Resolution | 1VA (0 to 3700VA) |
Display Range | 0 to 3990VA |
Extension Lead Test | |
Tests Performed | Bond, insulation and polarity |
Polarity Test Voltage | 12V |
Polarity checks | Lead ok Live neutral S/C Live neutral reversed Live/neutral O/C |
Flash Test | |
Flash Test Voltage | 1500V AC nominal for class 1 3000V AC nominal for class 2 |
Flash Test Current | <3.5mA short circuit @ 253V primary supply voltage |
Flash Test Breakdown Current Accuracy | ±5% ±5 digits |
Flash Test Breakdown Current Resolution | 0.01mA |
Display Range | 0 to 3.0mA |
Portable RCD Test | |
Test Voltage and Frequency | Nominal mains supply |
Test Current Accuracy | -8% to -2% (1/2 x I) +2 to +8% (1 x I, 5 x I) |
Trip Time Accuracy | ±1% ± 5 digits |
Trip Time Resolution | 0.1ms |
Display Range | 0 to 1999ms (1/2 x I) 0 to 300ms (1 x I) 0 to 40ms (5 x I) |
Fuse Test | |
Test Voltage | 3.3V |
Warning | Audible beep if fuse is OK |
Environmental | |
Operating Temperature | -10 to 50°C |
Storage Temperature | -20 to 60°C |
Humidity | 90% RH @ -10 to 30°C 75% RH @ +30 to 50°C |
Maximum Altitude | 2000m |
Ingress Protection | IP40 |
Other | |
Weight | 5.0kg |
Dimensions | 210 (H) x 280 (W) x 390mm (L) |
Safety | IEC 61010-1: CAT II 300V |
EMC | IEC 61326-1: 2006 IEC 61326-2-2: 2005 |
Reviews
SKU | PAT450BUNDLE4 |
---|---|
Manufacturer Part Code | PAT450BUNDLE4 |