Megger PAT450 Downloadable PAT Tester
The Megger PAT450 is the top-of-the-line PAT tester from Megger. If you need a comprehensive PAT testing solution, this is the one for you. This PAT tester is almost identical to the PAT420, with the main difference being that the PAT450 also has built-in flash testing capabilities at 1.5kV and 3kV. This testing mode makes the PAT450 perfect for tool-hire shops where equipment is regularly tested before being rented out, or for service workshops where thorough disassembly is common. It's worth noting that the PAT450 is the only model in the series with flash testing capabilities.
Like all other PAT400 series models, the PAT450 is equipped as standard with 10,000 record internal memory, making it easy to manage all of your testing records and appliance data. All results can be transferred to PC by inserting a USB stick into the PAT450 before inserting into your PC. For ease of use, results are exported in CSV format (compatible with Microsoft Excel) or you can buy Megger's PAT450 software (sold separately) for full database management of everything from appliance results to customer data (as well as getting a number of other benefits such as the ability to create reports).
Megger's PAT450 is made for testing all appliances. As standard it includes both 230V and 110V supply (plus a 110V socket) for testing 230V and 110V appliances and leads, or can be used to test 415V equipment by using a set of appropriate 415V adapters. This tester is also IT safe and won't damage sensitive IT equipment when testing in low current mode and is fully suitable for testing class I and class II appliances and all associated power and extension leads.
PAT testing is made simple thanks to built-in auto testing routines. If you require more control over testing, you can also use the manual mode to configure your test times and select pass limits, making this tester a truly comprehensive PAT testing solution.
There's even more to it to! The PAT450 includes a full colour screen, built-in QWERTY keyboard, fuse check function and even a lead storage pouch.
Videos
Key Features
- Megger's best PAT tester
- Earth bond/continuity testing at 200mA, 10A and 25A, catering for a wide variety of appliances
- Built-in 110V connector - no need to use external 110V adapters
- Flash testing capabilities at 1.5kV and 3.0kV (NEW for this model)
- Keep track of all of your measurement results with 10,000 record built-in memory storage
- Download testing results to PC in CSV format (compatible with Excel) or purchase Megger's optional Powersuite software for full database management
- Easy asset management using the tester using built-in QWERTY keyboard and function keys
- Manual and automatic testing modes - speed up your testing with automatic test routines, or adjust testing times and pass limits in manual mode
- Insulation testing at 250V and 500V
- Substitute, differential and touch current leakage tests
- Operational VA test
- Earth bond, insulation, polarity and extension lead tests
- Portable RCD tests
- Built-in lead storage pouch
- Full colour, large-size VGA screen
- Can be used with optional barcode scanners and printers (sold separately)
What's Included?
- Megger PAT450 Downloadable PAT Tester
- Printed Quick Start Guide
- Full User Guide on CD
- Calibration Certificate
- Continuity/Earth Bond Lead + Probe
- Extension Lead Adaptor (13A)
- Carry Case w/ Lead/Document Pouch
- Plug Adaptor IEC C6 - C13 (3 Way 5A PSU)
- Flash Lead (3.0kV, 3.5mA)
Exclusive PAT Testing Kits
How about a kit that includes everything you get as standard, plus additional accessories, for one low price?
Exclusively available from PASS, our kits are great value and give you everything you need for PAT testing.
We offer the following kits:
Item
PAT Essentials Kit (Bundle 1) | PAT Business Kit (Bundle 2) |
PAT Premium Kit (Bundle 3) | PAT Elite Printer Kit (Bundle 4) | |
---|---|---|---|---|
UNI-T UT07A Socket Tester Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
Yes | Yes | Yes | Yes |
CK Tools AV05050 Screwdriver Set This bundle pack includes a set of 5 fully insulated electrical screwdrivers which are suitable for live electrical work to 1000V |
Yes | Yes | Yes | Yes |
PAT Testing Training DVD + Online Examination for 1 Person Not trained to perform PAT testing? With our training DVD, you can learn from your workplace or at home how to PAT test! |
Yes | Yes | Yes | Yes |
PASS PAT Testing Handbook A comprehensive, extremely detailed guidebook with useful information, diagrams, pictures and case studies related to PAT testing. |
Yes | Yes | Yes | Yes |
Microwave Leakage Detector It's common practice to check microwave radiation levels while you're PAT testing - use this portable, easy-to-use microwave leakage detector to do so |
Yes | Yes | Yes | Yes |
IEC Adapter Set A special bundle pack with three IEC adapters, allowing you to use your PAT tester with various types of IEC cables and power supplies |
Yes | Yes | Yes | Yes |
110V Adapter Set Use these two 110V connector leads to connect your PAT tester to 110V equipment commonly found on construction sites and similar applications |
Yes | Yes | Yes | Yes |
Passed PAT Testing Labels A PAT essential! We include two 500 label rolls in your purchase, ensuring you have everything you need for labelling appliances after testing |
Yes, 1000x | Yes, 1000x | Yes, 1000x | Yes, 500x |
1000 x Circular Passed PAT Labels Uniquely-designed passed PAT testing labels with circular design - ideal for smaller plugs or appliances where you can't easily fit other labels |
Yes, 500x | Yes, 1000x | Yes, 1000x | Yes, 500x |
500 x PAT Testing Cable Wrap Labels These labels wrap around cables, and are great for labelling appliance power leads where you can't fix a suitable label |
Yes, 500x | Yes, 500x | Yes, 500x | Yes, 500x |
500 x Failed PAT Testing Labels You won't need these very often, but if an appliance ever fails testing you should place one of these labels and take it out of use for repair or replacement |
Yes, 500x | Yes, 500x | Yes, 500x | Yes, 500x |
Visual Inspection Labels You should check your appliances over for obvious signs of damage before testing. Look for frayed wires, loose connection and damaged plugs, then place one of these labels on if the appliance passes |
No | Yes | Yes | Yes |
Megger Powersuite Contractor Software Use Megger's software alongside your PAT tester to download your results to PC and keep a database of all of your findings |
No | Yes | Yes | Yes |
Barcode Scanner This Bluetooth/USB barcode scanner is great for speeding up your record keeping by using your Megger PAT tester and barcode labels |
No | No | Yes | Yes |
Barcode Labels Pair these up with your Bluetooth barcode scanner and quickly recall your previous records, or make new records, using your Apollo series PAT tester |
No | No | Yes, 2000x | Yes, 1000x |
Brother Printer and Printer Cartridge Create customised labels when out testing with this portable printer and cartridge pack! |
No | No | No | Yes |
Accessories
There are a number of accessories available for the Megger PAT450 PAT Tester with Flash; please see the table below for further details. For further information please contact our sales team.
Our SKU | Megger's Part Number | Product |
1000-766 | 1000-766 | 110V Mains Lead Adaptor BS1363 - BS4343 |
1000-767 | 1000-767 | 415V Adaptor Lead (4 Pin) TO BS (16A) |
1000-770 | 1000-770 | 415V Adaptor Lead (5 Pin) TO BS (16A) |
1000-971 | 1000-971 | Pass Test Labels (1000) Green UK |
1001-227 | 1001-227 | Fail Test Labels (1000) Red |
PT-P700 | PT-P700 | Barcode Printer Brother P700 |
1001-047 | 1001-047 | Barcode Scanner (USB) |
1001-299 | 1001-299 | PATR210 PAT Report Book |
2000-551 | 1001-232 | Plug Adaptor IEC C6-C13 |
2000-870 | 1001-233 | Continuity/Bond Lead Set 32A |
1001-234 | 1001-234 | Extension Lead Adaptor 230V UK 13A |
MEGPTA8 | 6220-639 | Extension Lead Adapter - 110V |
2001-044 | 2001-044 | PAT Accessory Case |
2001-372 | 2001-372 | PAT Testing Guide Book |
1004-610 | 1004-610 | Lead USB Type A to Type B 1.8m |
MEGPTA22 | 6121-483 | Barcode Labels (Preprinted) - 1000 per roll |
90001-010 | 9001-010 | Printer Cartridge for Brother PT-9500PC |
2000-962 | 1006-225 | Carry Case PAT300/400/500 |
MEGPTA12 | 1007-165 | Flash Test Lead 3.0KV 3.5mA (Red) |
MEGSW1 | 1000-631 | Powersuite Lite - 17th Edition and PAT Certification Software |
Please note that the accessories listed above and the attached datasheets are subject to change. Both were correct at the time of publication. |
Megger PAT450 Technical Specifications
Electrical Supply Range | 230V ±10 @ 50/60Hz 110V ± 10% + 110V ±10% @50Hz |
Bond Test (10A and 25A) | |
Open Circuit Voltage | 9V AC ±10% ± 0.1V (supply: 230V 50Hz) |
Earth Bond Resistance Accuracy | ±5% ± 3 digits (0 to 0.49Ω) ±5% ±5 (0.5 to 0.99Ω) |
Display Range | 0 to 1.99Ω |
Continuity Test (200mA) | |
Continuity Test Voltage | 9V AC ± 10% ± 0.1V (supply: 230V 50Hz) |
Continuity Resistance Accuracy | ±5% ± 3 digits (0 to 0.49Ω) ±5% ± 5 digits (0.5 to 0.99Ω) |
Continuity Resistance Resolution | 10mΩ (1 to 19.99Ω) |
Display Range | 0 to 19.99Ω |
Insulation Test (250V and 500V) | |
Insulation Resistance Accuracy (230V) | ±2% ±5 digits (0 to 19.99MΩ) ±5% ± 10 digits (20 to 99.99MΩ) |
Insulation Resistance Resolution | 0.01MΩ |
Display Range | 0 to 99.99MΩ |
Substitute Leakage Test | |
Test Voltage and Frequency | 40V AC ±10% nominal mains frequency |
Leakage Current Accuracy | ±5% ± 5 digits |
Leakage Current Resolution | 0.01mA |
Display Range | 0 to 19.99mA |
Differential Leakage Current | |
Test Voltage | Nominal mains 110/230V AC |
Test Frequency | Nominal mains 50/60Hz |
Differential Leakage Current Accuracy | ±5% ± 0.05mA (1.0mA to 9.99mA) ±5% ± 0.1mA (0.1mA to 0.99mA) |
Resolution | 0.01mA |
Display/Measurement Range | 0.10mA to 19.99mA |
Test Duration | User-selectable from 1 sec 10 sec to infinity |
Touch Current Test | |
Test Voltage and Frequency | Nominal mains supply |
Touch Current Accuracy | ±5% ± 5 digits |
Touch Current Resolution | 0.01mA |
Display | 0 to 10mA |
Operational Test | |
Test Voltage and Frequency | Nominal mains supply |
VA Rating | 230V 3700VA 110V 1800VA |
VA Accuracy | ±5% ± 10 digits (0 to 99VA) ±5% ± 50 digits (100VA to 999VA) ±5% ± 100 digits (1000VA to 3700VA) |
Resolution | 1VA (0 to 3700VA) |
Display Range | 0 to 3990VA |
Extension Lead Test | |
Tests Performed | Bond, insulation and polarity |
Polarity Test Voltage | 12V |
Polarity checks | Lead ok Live neutral S/C Live neutral reversed Live/neutral O/C |
Flash Test | |
Flash Test Voltage | 1500V AC nominal for class 1 3000V AC nominal for class 2 |
Flash Test Current | <3.5mA short circuit @ 253V primary supply voltage |
Flash Test Breakdown Current Accuracy | ±5% ±5 digits |
Flash Test Breakdown Current Resolution | 0.01mA |
Display Range | 0 to 3.0mA |
Portable RCD Test | |
Test Voltage and Frequency | Nominal mains supply |
Test Current Accuracy | -8% to -2% (1/2 x I) +2 to +8% (1 x I, 5 x I) |
Trip Time Accuracy | ±1% ± 5 digits |
Trip Time Resolution | 0.1ms |
Display Range | 0 to 1999ms (1/2 x I) 0 to 300ms (1 x I) 0 to 40ms (5 x I) |
Fuse Test | |
Test Voltage | 3.3V |
Warning | Audible beep if fuse is OK |
Environmental | |
Operating Temperature | -10 to 50°C |
Storage Temperature | -20 to 60°C |
Humidity | 90% RH @ -10 to 30°C 75% RH @ +30 to 50°C |
Maximum Altitude | 2000m |
Ingress Protection | IP40 |
Other | |
Weight | 5.0kg |
Dimensions | 210 (H) x 280 (W) x 390mm (L) |
Safety | IEC 61010-1: CAT II 300V |
EMC | IEC 61326-1: 2006 IEC 61326-2-2: 2005 |
Reviews
SKU | 1000-755 |
---|---|
Manufacturer Part Code | 1000-755 |
Model Ref | PAT450 |
Country of Origin | United Kingdom |