The Megger PAT250 Series is operated and includes Bluetooth software. Bluetooth enables you to manage your testing through wireless control from your device. The cloud storage safely stores your results, which can be accessed from anywhere at any time.
A one-year CertSuite PAT Software licence is included with the PAT250 Series. After the first year, the licence becomes subscription-based (please contact Megger for further information). CertSuite PAT simplifies recording test results, generates professional reports, and supports unlimited jobs and reports.
The intuitive mobile interface is mobile-compatible and requires minimal training. The instruments are easy to store and transport and have rubber-armoured cases with scratch-proof glass.
Key Features
- CertSuite PAT software included (1 year licence*)
- Control of testing from CertSuite PAT
- Save results to the cloud and produce reports quickly
- Simple tick or cross for a pass or fail indication
- Battery-powered with rechargeable options
- Safe 250 V insulation and leakage test for surge-protected and IT equipment
- Continuity test 200 mA
- Substitute leakage testing
- Mains powered and 10 mA and 30 mA portable RCD lead testing
- Fast testing and report generation
- Tough, rubber armour with a built-in front cover and lightweight for portability
Note: *After 1 year a subscription charge applies please see megger.com for further information.
What's Included?
- Tester
- Extension lead adaptor
- Mains plug test lead
- Continuity/earth bond lead (1001-233)
- SELV/mains voltage test lead Red (1005-077)
- Carry case (1005-075)
- AC Mains charger - multi-country (1003-436) - PAT250SRX Model only
Product Range
- Megger PAT250SX UK PAT Tester with CertSuite & Bluetooth
- Megger PAT250SRX UK PAT Tester & AC Mains Charger with CertSuite & Bluetooth (Rechargeable)
- PAT Testing Reference Card 5th Edition - PAT-TEST-CARD, typically £5.00
Environmental Condition | |
---|---|
Operating Ambient | 20 °C |
Humidity | 45% rh ± 20 points |
Continuity Test | |
Test Voltage | Compliance voltage: +4 V DC -0% / +30% (open circuit) |
Test Current | Bi-directional +200 mA -0 % + 50 mA (into 2 Ω load) |
Continuity Accuracy | Resistance: ± 5% ± 3 digits (0 to 19.99 Ω) |
Resolution | Resistance 10 mΩ |
Display Range | 0.01 to 19.99 Ω |
Continuity | test nulling up to 9.99 Ω |
Test Time | User selectable from 2s to 20s or selected during test to 180s |
Insulation Test | |
Insulation Test | 250 V DC -0% +25% open circuit 500 V DC -0% +25% open circuit ≥ 500 V 0% DC across 0.5 MΩ load |
Short Circuit/charge Current | < 2mA DC |
Insulation Accuracy | ± 3% ± 10 digits (0 to 19.99 MΩ) |
Resolution | 0.01 mA |
Display Range | 0.10 MΩ to 99.99 MΩ |
Test Duration | User selectable from 2s to 20s or selected during test to 180s |
Substitute Leakage Test | |
Leakage Current | Accuracy ± 5% ± 3 digits |
Test Frequency | Nominal mains frequency 50 Hz |
Test Voltage | < 50V ac |
Resolution | 0.01 mA |
Display Range | 0.10 to 19.99 mA |
Test Duration | 0.01 mA |
Display Range | User selectable from 2s to 5s Reading corrected to 230 V AC |
Differential Leakage Current | |
Test Voltage | Nominal supply voltage 230 V AC |
Test Frequency | Nominal mains frequency 50 Hz |
Test Accuracy | ± 5% ± 3 digits ± 3 uA/A |
Resolution | 0.01 mA |
Display Range | 0.10 to 19.99 mA |
Test Duration | User selectable from 2s to 5s |
Touch Current Test | |
Test Voltage | Nominal mains 230 V AC |
Test Frequency | Nominal mains 50 Hz |
Test Accuracy | ± 5% ± 3 digits |
Resolution | 0.01 mA |
Display Range | 0.10 to 3.99 mA |
Test Duration | User selectable from 2s to 5s |
SELV Device Test | |
Test Voltage | 0 to 300 V AC |
Test Accuracy | ± 3% ± 3 digits |
Resolution | 0.1 V AC |
Display Range | 0.1 to 300 V AC |
Extension Lead Test | |
Test Voltage | 5 V |
Polarity | Lead OK Live/neutral shorted Live/neutral reversed Live/neutral open circuit |
Extension Portable RCD Test | |
Test Voltage | Nominal mains 230 V |
Test Frequency | 50 Hz |
Test Current Accuracy | +2 % to +9 % (1 x I, 5 x I) |
Test accuracy | Trip time ± 1 % ± 1 ms |
Resolution | Trip time 0.01 ms |
Display Range | 0 to 200 ms (1 x I) 0 to 40 ms (5 x I) |
Main Supply Test | |
Frequency Measurement Range | 50 Hz |
Test Voltage | 40 to 300 V AC |
Test Accuracy | ± 3% ± 3 digits |
Resolution | 0.1 V AC |
Display Range | 40 to 300 V AC |
Circuit Test (Carried out automatically, not available to user) |
|
Test Voltage | 5 V |
Test Frequency | Nominal mains 50 Hz |
Test Current | < 100mA short-circuit |
Safety | |
PAT250 | Instrument designed to IEC 61010-1: 2010 Test leads designed to IEC 61010-031: 2008 300 V to Earth Category II Mains fuse protection to 250 V rms AC |
EMC Design to meet IEC 61326-1: 2012 and IEC 61326-2-2: 2005. |
|
Performance Standard | BS EN 50678:2020 BS EN 50699:2020 |
User Replaceable Fuse | 13 A fused mains plug (PAT250-UK only) One F 100 mA 250 V 5x20 mm HBC |
Operating Temperature | 0 °C to +40 °C |
Storage Temperature | -20 °C to +60 °C |
Humidity | 90 % RH @ +10 °C to +30 °C 75 % RH @ +10 °C to +60 °C |
Operating Altitude | up to 2,000 m |
IP Rating | IP40 (with front cover closed) |
Mechanical | |
Battery Life | Over 1000 full Class 1 tests using 3400 mAh Alkaline battery |
Battery Type | Eight AA LR6 cells 12 V DC (Alkaline cells) 9.6 V DC (NiMH cells) |
Weight | PAT250 (instrument) 1300g (45.8 oz) - (shipping) 2795g (98.6 oz) PAT250SRX (instrument) 1300g (45.8 oz) - (shipping) 2975g (104.9 oz) |
Dimensions | Instrument and case 203 (L) x 148 (W) x 78 mm (H) (8 x 5.7 x 3.2 inches) |
Reviews
SKU | PAT250 |
---|