FREE - PASS The Complete Guide to EET (PAT) Testing, 5th Edition
Buy a PAT testing kit and get an updated PAT Testing Guide worth £24.99. This 129 page indepth PAT testing book is a great addition to your kit. View PAT Guide
Megger PAT150 PAT Tester - Kit 2
Our biggest and best Megger PAT150 bundle pack! Shipping with everything included in bundle 1, plus software for managing your results on PC, this kit is excellent for any PAT professional. Recommended for use in offices, charity shops, other retail outlets, by landlords, schools and anywhere else with a small amount of appliances to test.
Key Features
- Easy to use - simple tick/cross PASS/FAIL indication plus full display of testing results
- Exclusive portable RCD testing mode for 10mA and 30mA RCDs
- 500V and 250V insulation procedures make the tester suitable for use on IT and surge protected equipment
- Continuity testing
- Mains powered leakage testing
- SELV measurements
- Quick test button
- User-configurable test group pass limits and test duration
- Bond lead resistance can be nulled to reduce measurement errors
- Live circuit measurements for testing mains supply and socket polarity
- Suitable for testing fixed appliances
- Tough armoured carrying case with protective lid plus high durability screen with scratchproof technology
What's In the Kit?
Inside this bundle pack you will receive the following standard kit from the manufacturer:
- Megger PAT150 PAT Tester
- Continuity/Earth Bond Lead
- SELV/Mains Voltage Test Lead
- Extension Lead Adapter
- Mains Plug Test Lead
- Carry Case
You will also receive all of the following as part of our PAT Essentials kit:
- Soft Shell Carrying Case - Keep all of your equipment safe and in one place with this large-size carrying case with a customisable foam insert
- Socket Tester - think there's a problem with your sockets in your premises? Plug this in and it'll instantly detect different wiring faults
- eLearning PAT Testing Course - Includes Exam and Certificate - fully accredited solution for training to PAT test from your own home or workplace. Take our online examination and once passed you can print out your certificate
- PASS PAT Testing Logbook - it's good practice when PAT testing to jot down your results in order to keep a record of the test - this logbook makes this process quick and easy
- Microwave Leakage Detector - check that microwaves in your premises are working correctly and letting out the correct levels of radiation with this easy-to-use detector
- IEC Adapter Set - you'll need these adapters to connect your Megger PAT120 to various different IEC-type appliances and leads such as computers or laptop power supplies
- CK Tools AV05050 5 Piece Insulated Screwdriver Kit - high quality set of 5 screwdrivers fully insulated to 1000V for use by electricians
- 500 x Passed PAT Testing Labels - a true PAT essential! You'll be placing these labels on every appliance that successfully passed the PAT testing procedure
- 500 x Circular Passed PAT Testing Labels - unique, circular-shaped smaller PAT labels ideal for use on plugs or smaller appliances where other labels may not fit
- 250 x Cable Wrap PAT Labels - these labels wrap around a cable, and are great for marking that power leads have been tested
- 250 x Failed PAT Testing Labels - place these on any appliance that fails testing and take it out or service for repair or replacement immediately
- SimplyPATS Manual Entry Software - keep track of your PAT records by typing them into this comprehensive PC software package
Get More with Our Megger PAT150 PAT Kits!
If you're looking for a comprehensive PAT kit - we've got you covered.
We have two different, great value kit versions of the Megger PAT120 available - take a look at the table below for a closer look about what's in each.
Item Description | Megger PAT150 PAT Essentials Kit (Bundle 1) | Megger PAT150 PAT Tester Professional Kit (Bundle 2) |
---|---|---|
Deluxe Carrying Case Keep all of your equipment safe and in one place with this large-size carrying case! (appearance of case may vary depending on current stock) |
√ | √ |
Socket Tester Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
√ | √ |
eLearning PAT Testing Course - Includes Exam and Certificate Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
√ |
√ |
PASS PAT Testing Logbook Keep a record of all of your testing with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference. |
√ | √ |
Microwave Leakage Detector When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector you'll be able to do this testing with ease. |
√ | √ |
PASSPTA21 - IEC (C13 Female) You'll need this adaptor to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector. |
√ | √ |
PASSPTA29 - IEC Plug (C14) This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment. |
√ | √ |
PASSPTA28 - IEC Plug (C14) You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adaptor, you can connect them up to your PAT tester. |
√ | √ |
CK Tools AV05050 5 Piece Insulated Screwdriver Kit A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications. |
√ | √ |
WM1 - 500 x Passed PAT Testing Labels You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done. |
√ | √ |
WM6500 - 500 x Circular Passed PAT Testing Labels These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due. |
√ | √ |
WM12 250 - 250 x Cable Wrap Labels These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date. |
√ | √ |
WM7 250 - 250 x Failed PAT Testing Labels You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement |
√ | √ |
SimplyPats Manual PAT Testing Software Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand. |
- | √ |
- PASS The Complete Guide to EET (PAT) Testing, 5th Edition - PASS-PAT-HB, typically £24.99
Megger PAT100 Series Technical Specifications
Specifications | Megger PAT120 | Megger PAT150 |
---|---|---|
Environmental Conditions | ||
Operating Ambient | 20°C | 20°C |
Humidity | Nominal humidity | Nominal humidity |
Continuity Testing | ||
Test Voltage | Compliance voltage: +4V DC -0 / +10% (open circuit) |
Compliance voltage: +4V DC -0 / +10% (open circuit) |
Test Current | Bi-directional +200mA -0% + 50mA (into 2Ω load) |
Bi-directional +200mA -0% + 50mA (into 2Ω load) |
Continuity Accuracy | Resistance: ±5% ± 3 digits (0 to 19.99Ω) | Resistance: ±5% ± 3 digits (0 to 19.99Ω) |
Resistance Resolution | 10mΩ | 10mΩ |
Display Range | 0.01 to 19.99Ω | 0.01 to 19.99Ω |
Continuity Test Nulling | Up to 9.99Ω | Up to 9.99Ω |
Test Duration | Selected during test automatically | User-selectable from 2 seconds to 20 seconds or selected during test to 180 seconds |
Insulation Test | ||
Insulation Procedure | 250V DC: -0% / +25% open circuit | 250V DC: -0% / +25% open circuit 500V DC: -0% / +25% open circuit ≥ 500V 0% DC across 0.5MΩ load |
Short Circuit/Charge Current | <2mA DC | <2mA DC |
Insulation Accuracy | ±3% ± 10 digits (0 to 99.9MΩ) | ±3% ± 10 digits (0 to 99.9MΩ) |
Resolution | 0.01MΩ | 0.01MΩ |
Display Range | 0.10M to 99.99MΩ | 0.10M to 99.99MΩ |
Test Duration | Selected during test automatically | User selectable from 2 seconds to 20 seconds or selected during test to 180 seconds |
Substitute Leakage Test | ||
Leakage Current | Accuracy ±5% ± 3 digits | Accuracy ±5% ± 3 digits |
Test Frequency | Nominal mains frequency 50Hz | Nominal mains frequency 50Hz |
Test Voltage | <50V AC | <50V AC |
Resolution | 0.01mA | 0.01mA |
Display Range | 0.10 to 19.99mA | 0.10 to 19.99mA |
Test Duration | User-selectable from 2 secs to 5 seconds | User-selectable from 2 secs to 5 seconds |
Differential Leakage Test (PAT150 Only) | ||
Test Voltage | - | Nominal supply voltage 230V AC |
Test Frequency | - | Nominal mains frequency 50Hz |
Test Accuracy | - | ±5% ±3d ± 3μA/A |
Resolution | - | 0.01mA |
Display Range | - | 0.10 to 19.99mA |
Test Duration | - | User-selectable from 2 seconds to 5 seconds |
Touch Current Test (PAT150 Only) | ||
Test Voltage | - | Nominal mains 230V AC |
Test Frequency | - | Nominal mains 50Hz |
Test Accuracy | - | ±5% ± 3 digits |
Resolution | - | 0.01mA |
Display Range | - | 0.10 to 3.99mA |
Test Duration | - | User-selectable from 2 seconds to 5 seconds |
SELV Device Test (PAT150 Only) | ||
Test Voltage | - | 0 to 300V AC |
Measurement Accuracy | - | ±3% ± 3 digits |
Resolution | - | 0.1V AC |
Display Range | - | 0.1 to 300V AC |
Extension Lead Test | ||
Test Voltage | 5V | 5V |
Polarity | Lead OK Live/neutral shorted Live/neutral reversed Live/neutral open circuit |
Lead OK Live/neutral shorted Live/neutral reversed Live/neutral open circuit |
Portable RCD Test (PAT150 Only) | ||
Test Voltage | - | Nominal mains 230V |
Test Frequency | - | 50Hz |
Test Current Accuracy | - | +2% to +8% (1 x I, 5 x I) |
Trip Time Accuracy | - | ±1% ± 1ms |
Trip Time Resolution | - | 0.01ms |
Display Range | - | 0 to 200ms (1 x I) 0 to 40ms (5 x I) |
Mains Supply Test (PAT150 Only) | ||
Frequency Measurement Range | - | 50Hz |
Test Voltage | - | 40 to 300V AC |
Accuracy | - | ±3% ± 3 digits |
Resolution | - | 0.1V AC |
Display Range | - | 40 to 300V AC |
Circuit Test | ||
Test Voltage | 5V | 5V |
Test Frequency | Nominal mains 50Hz | Nominal mains 50Hz |
Test Current | <100mA short circuit | <100mA short circuit |
Safety | Instrument designed to IEC 61010-1: 2012 Test leads designed to IEC 61010-031:2005 300 volts to Earth Category II Mains fuse protection to 250V RMS AC |
Instrument designed to IEC 61010-1: 2012 Test leads designed to IEC 61010-031:2005 300 volts to Earth Category II Mains fuse protection to 250V RMS AC |
EMC | Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 | Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 |
Environmental | ||
Operating Temperature | 0 to 40°C | 0 to 40°C |
Storage Temperature | -20 to 60°C | -20 to 60°C |
Humidity | 90% RH @ 10 to 30°C 75% RH @ 30 to 40°C |
90% RH @ 10 to 30°C 75% RH @ 30 to 40°C |
Max Altitude | 2000m to full safety spec | 2000m to full safety spec |
IP Rating | IP40 (with front cover closed) | IP40 (with front cover closed) |
Mechanical (Batteries) | ||
Battery Life | 3 days based on 120 tests/day using 2000mAh alkaline batteries | 3 days based on 120 tests/day using 2000mAh alkaline batteries |
Battery Type | Supply voltage 12V DC (alkaline AA LR6) 9.6V DC (NiMH AA LR6) |
Supply voltage 12V DC (alkaline AA LR6) 9.6V DC (NiMH AA LR6) |
Weight | 1150g | 1300g |
Dimensions | 203mm (L) x 148mm (W) x 78mm (H) | 203mm (L) x 148mm (W) x 78mm (H) |
Reviews
SKU | PAT150BUNDLE2 |
---|---|
Manufacturer Part Code | PAT150BUNDLE2 |