Get everything you need to get started PAT testing with our Megger PAT120 PAT Essentials Kit! Inside the kit you will receive all standard accessories you'd normally receive from Megger, plus an exclusive, reduced-cost PAT Essentials bundle pack of accessories you'll be using during PAT testing.
Megger's PAT120 is a simple-to-use, entry-level PAT tester built inside its own carrying case. We'd highly recommend this tester for use by smaller businesses who want to do their own PAT testing, for use in charity shops, as a PAT tester for a landlord or in other applications where you may have a smaller amount of appliances to test. It designed to give simple, quick indication of the safety of electrical appliances with quick, easy access to all testing procedures with clear, easy-to-read results on the built-in screen.
For new users, Megger's test group function, which groups together the correct sequence of tests for different appliances, ensures that you perform all tests with minimum effort on your part. With this mode, you simply connect to the appliance, press a few buttons and the PAT120 will do the rest. Test groups are available for class I and class II appliances as well as extension and power leads.
Inside this bundle pack you will receive the following standard kit from the manufacturer:
You will also receive all of the following as part of our PAT Essentials kit:
If you're looking for a comprehensive PAT kit - we've got you covered. We have two different, great value kit versions of the Megger PAT120 available - take a look at the table below for a closer look about what's in each.
Item Description | Megger PAT120 PAT Essentials Kit (Bundle 1) | Megger PAT120 PAT Tester Professional Kit (Bundle 2) |
---|---|---|
Soft Shell Carrying Case Keep all of your equipment safe and in one place with this large-size carrying case with a customisable foam insert (The appearance of the case may vary depending on current stock) |
√ | √ |
Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
√ | √ |
Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
√ |
√ |
Keep a record of all of your testing with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference. |
√ | √ |
When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector you'll be able to do this testing with ease. |
√ | √ |
You'll need this adaptor to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector. |
√ | √ |
This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment. |
√ | √ |
You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adaptor, you can connect them up to your PAT tester. |
√ | √ |
A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications. |
√ | √ |
You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done. |
√ | √ |
These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due. |
√ | √ |
These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date. |
√ | √ |
You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement |
√ | √ |
Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand. |
- | √ |
Specifications | Megger PAT120 | Megger PAT150 |
---|---|---|
Environmental Conditions | ||
Operating Ambient | 20°C | 20°C |
Humidity | Nominal humidity | Nominal humidity |
Continuity Testing | ||
Test Voltage | Compliance voltage: +4V DC -0 / +10% (open circuit) |
Compliance voltage: +4V DC -0 / +10% (open circuit) |
Test Current | Bi-directional +200mA -0% + 50mA (into 2Ω load) |
Bi-directional +200mA -0% + 50mA (into 2Ω load) |
Continuity Accuracy | Resistance: ±5% ± 3 digits (0 to 19.99Ω) | Resistance: ±5% ± 3 digits (0 to 19.99Ω) |
Resistance Resolution | 10mΩ | 10mΩ |
Display Range | 0.01 to 19.99Ω | 0.01 to 19.99Ω |
Continuity Test Nulling | Up to 9.99Ω | Up to 9.99Ω |
Test Duration | Selected during test automatically | User-selectable from 2 seconds to 20 seconds or selected during test to 180 seconds |
Insulation Test | ||
Insulation Procedure | 250V DC: -0% / +25% open circuit | 250V DC: -0% / +25% open circuit 500V DC: -0% / +25% open circuit ≥ 500V 0% DC across 0.5MΩ load |
Short Circuit/Charge Current | <2mA DC | <2mA DC |
Insulation Accuracy | ±3% ± 10 digits (0 to 99.9MΩ) | ±3% ± 10 digits (0 to 99.9MΩ) |
Resolution | 0.01MΩ | 0.01MΩ |
Display Range | 0.10M to 99.99MΩ | 0.10M to 99.99MΩ |
Test Duration | Selected during test automatically | User selectable from 2 seconds to 20 seconds or selected during test to 180 seconds |
Substitute Leakage Test | ||
Leakage Current | Accuracy ±5% ± 3 digits | Accuracy ±5% ± 3 digits |
Test Frequency | Nominal mains frequency 50Hz | Nominal mains frequency 50Hz |
Test Voltage | <50V AC | <50V AC |
Resolution | 0.01mA | 0.01mA |
Display Range | 0.10 to 19.99mA | 0.10 to 19.99mA |
Test Duration | User-selectable from 2 secs to 5 seconds | User-selectable from 2 secs to 5 seconds |
Differential Leakage Test (PAT150 Only) | ||
Test Voltage | - | Nominal supply voltage 230V AC |
Test Frequency | - | Nominal mains frequency 50Hz |
Test Accuracy | - | ±5% ±3d ± 3μA/A |
Resolution | - | 0.01mA |
Display Range | - | 0.10 to 19.99mA |
Test Duration | - | User-selectable from 2 seconds to 5 seconds |
Touch Current Test (PAT150 Only) | ||
Test Voltage | - | Nominal mains 230V AC |
Test Frequency | - | Nominal mains 50Hz |
Test Accuracy | - | ±5% ± 3 digits |
Resolution | - | 0.01mA |
Display Range | - | 0.10 to 3.99mA |
Test Duration | - | User-selectable from 2 seconds to 5 seconds |
SELV Device Test (PAT150 Only) | ||
Test Voltage | - | 0 to 300V AC |
Measurement Accuracy | - | ±3% ± 3 digits |
Resolution | - | 0.1V AC |
Display Range | - | 0.1 to 300V AC |
Extension Lead Test | ||
Test Voltage | 5V | 5V |
Polarity | Lead OK Live/neutral shorted Live/neutral reversed Live/neutral open circuit |
Lead OK Live/neutral shorted Live/neutral reversed Live/neutral open circuit |
Portable RCD Test (PAT150 Only) | ||
Test Voltage | - | Nominal mains 230V |
Test Frequency | - | 50Hz |
Test Current Accuracy | - | +2% to +8% (1 x I, 5 x I) |
Trip Time Accuracy | - | ±1% ± 1ms |
Trip Time Resolution | - | 0.01ms |
Display Range | - | 0 to 200ms (1 x I) 0 to 40ms (5 x I) |
Mains Supply Test (PAT150 Only) | ||
Frequency Measurement Range | - | 50Hz |
Test Voltage | - | 40 to 300V AC |
Accuracy | - | ±3% ± 3 digits |
Resolution | - | 0.1V AC |
Display Range | - | 40 to 300V AC |
Circuit Test | ||
Test Voltage | 5V | 5V |
Test Frequency | Nominal mains 50Hz | Nominal mains 50Hz |
Test Current | <100mA short circuit | <100mA short circuit |
Safety | Instrument designed to IEC 61010-1: 2012 Test leads designed to IEC 61010-031:2005 300 volts to Earth Category II Mains fuse protection to 250V RMS AC |
Instrument designed to IEC 61010-1: 2012 Test leads designed to IEC 61010-031:2005 300 volts to Earth Category II Mains fuse protection to 250V RMS AC |
EMC | Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 | Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 |
Environmental | ||
Operating Temperature | 0 to 40°C | 0 to 40°C |
Storage Temperature | -20 to 60°C | -20 to 60°C |
Humidity | 90% RH @ 10 to 30°C 75% RH @ 30 to 40°C |
90% RH @ 10 to 30°C 75% RH @ 30 to 40°C |
Max Altitude | 2000m to full safety spec | 2000m to full safety spec |
IP Rating | IP40 (with front cover closed) | IP40 (with front cover closed) |
Mechanical (Batteries) | ||
Battery Life | 3 days based on 120 tests/day using 2000mAh alkaline batteries | 3 days based on 120 tests/day using 2000mAh alkaline batteries |
Battery Type | Supply voltage 12V DC (alkaline AA LR6) 9.6V DC (NiMH AA LR6) |
Supply voltage 12V DC (alkaline AA LR6) 9.6V DC (NiMH AA LR6) |
Weight | 1150g | 1300g |
Dimensions | 203mm (L) x 148mm (W) x 78mm (H) | 203mm (L) x 148mm (W) x 78mm (H) |