Megger's DLRO600 is a low resistance ohmmeter that can be used to quickly determine either a single measurement value or test resistance levels over a time period.
The measuring range of the DLR600 (subject to supply voltage and leads used) is from 0.1μΩ to 999.9mΩ. The tester uses varying test current from 10A up to 600A and all tests are carried out with high basic accuracy and resolution.
Three different testing modes are available on the DLR600: Normal, Continuous and Auto. Normal tests just like you'd expect and applies a current to measure resistance for a few seconds. Continuous maintains the test current over a time period to measure resistance differentials, and auto mode automatically applies the most applicable level of current to ensure that results are as accurate as possible. Tests on the DLR600 also use four-wire methods, ensuring that the effects of the resistance of the leads doesn't interfere with the resistance reading.
Once testing is finished the data can be directly stored on the DLR600's built-in memory which allows storage of up to 300 individual testing records. An alpha-numerical keypad also allows notes and adjustments to be made to stored data, while an RS232 port on the tester allows download to PC and a printer.
Megger DLRO600 Low Resistance Ohmmeter Key Features
- Small, lightweight design
- Test current from 10A to 600A DC
- 0.1μΩ best resolution
- Memory stores up to 300 testing records with nores
- Download to PC or a printer
- Keyboard for data entry
- Three measurement modes: Normal, Continuous and Auto
What's Included?
- Megger DLRO600 Low Resistance Ohmmeter
- 5m (16.4ft) Lead Set - 2 x 50mm Current Leads with Clips and 2 Potential Leads with Clips
- Download Manager
- User Guide on CD-ROM
- RS232 Download Cable
- Quick Start Guide in English/French
- Warranty Card
Megger DLRO600 Technical Specifications
Measurement Range | 0.1μΩ to 999.9mΩ (subject to supply voltage and leads used) |
Voltage Accuracy | ±0.5% ± 0.1mV |
Current Accuracy | ±0.5% ± 0.1A |
Resistance Accuracy | Better than 1% from 100μΩ to 100mΩ |
Output | |
Current Lead Resistance (Using Megger's Leads) | 2 x 5m 50mm² current leads: 4mΩ 2 x 10m 70mm² current leads: 5.4mΩ 2 x 15m 95mm² current leads: 6mΩ |
Maximum Continuous Test Time | More than 60 seconds at 600A @20°C ambient |
Full Output | 207 to 265V 50/60Hz with a load less than 7mΩ including current leads |
Reduced Output | Down to 100V 50/60Hz |
Test Modes | Manual, auto, continuous |
Test Time | 7 seconds NORMAL/AUTO mode Refresed every 2 seconds in CONTINUOUS mode |
Display | Large high resolution backlit liquid crystal display |
Warnings | Current flowing: - LED. Other warnings on LCD display |
Data Transfer | Real time or batch download via RS232 using download manager |
Storage Capacity | 300 result sets and memo, battery backed for 10 years |
Memo Field | 200 characters max |
Test Current | |
Range | 10 to 600A unsmoothed DC in 1A steps |
Accuracy | ±2% ± 2A |
Voltmeter Input Impedance | >200kΩ |
Hum Rejection | 5V RMS 50 Hz/60Hz |
Temperature | |
Operation | -10 to +50°C |
Storage | -25 to +65°C |
Calibration | 20°C |
Coefficient | <0.05% per °C |
Max Humidity | 95% RH non-condensing |
Max Altitude | 2000m |
Safety | IEC61010-1 |
EMC | IEC61326-1 |
Dimensions | 410 x 250 x 270mm |
Weight | 14.5kg (excluding test leads) |
Reviews
SKU | MEGLO6 |
---|---|
Manufacturer Part Code | 6411-015 |
Model Ref | DLRO600 |
Country of Origin | United Kingdom |