Please note that this version of the Megger DLRO10X does not ship as standard with the leadset required for measurements. If you require the lead set, you can buy part number 1006-600 instead which includes this.
The upgraded version of Megger's DLRO10, this tester is capable of everything the other tester could do and also includes a number of unique new features.
Easily the most useful upgrade is the addition of built-in memory to the tester. This enables users to automatically store test readings and recall them at a later date either on the tester or on a PC, ensuring that extensive analysis can be carried out on one testing point over time or comparisons can be made between different conductor measurements. The DLRO10X also includes an alpha-numeric keypad to allow the user to manually adjust records and the memory of the tester can be sent to a printer to print out testing records.
When testing, the DLRO10 uses a four terminal resistance method to negate the resistance of test leads, thus ensuring measurement accuracy. Multiple test modes are available on the device, including normal testing, auto testing (which applied forward and reverse current), continuous testing for repeated measurements and a special inductive mode for use on inductive devices such as motors etc. The DLRO10X also comes with a unique unidirectional mode which applies current in a single direction (this is designed to speed up the overall measurement process).
The Megger DLRO10 can use multiple ranges when testing. The following table outlines the specific testing procedures possible and relevant data when testing with this low resistance ohmmeter:
Resistance Ranges | Full Scale Volts | Test Current | ||||
Full Scale | Resolution | Accuracy* | Resistive | Inductive | Resistive | Inductive |
1.9999 mΩ | 0.1 μΩ | ±0.2% ±0.2μΩ | 20 mV | n/a | 10 A | n/a |
19.999 mΩ | 1 μΩ | ±0.2% ±2 μΩ | 20 mV | 20 mV | 1A | 1A |
199.99 mΩ | 10 μΩ | ±0.2% ±20 μΩ | 20 mV | 200 mV | 100mA | 1A |
1.9999 Ω | 100μΩ | ±0.2% ±0.2 mΩ | 20 mV | 200 mV | 10mA | 100mA |
19.999 Ω | 1 mΩ | ±0.2% ±2 mΩ | 20 mV | 200 mV | 1mA | 10mA |
199.99 Ω | 10 mΩ | ±0.2% ±20 mΩ | 20 mV | 200 mV | 100 μA | 1mA |
1999.9 Ω | 100 mΩ | ±0.2% ±0.2 Ω | 200 mV | 200 mV | 100 μA | 100 μA |
This tester also comes with a few additional features including a full LCD display of test results, automatic test procedures to make life easier and the ability to check for noise on circuits and limit testing if excessive noise is detected.
Test leads (please download the datasheet below for much more information on optional test leads):
The following table outlines the functionality of the Megger DLRO10 as well as the differences between the DLRO10 and the DLRO10X.
DLRO 10 | DLRO 10X | |
Measurement | ||
Mode | Manual, Auto, Continuous, Inductive | Manual, Auto, Continuous, Inductive, Undirectional |
Control | Fully Automatic |
Fully Automatic/Manual |
Speed |
<3s for forward & reverse current and to display average | |
Display | ||
Measurement | 4 1/2 digit seven segment LED | |
Range and Safety |
LED indication | Large backlit LCD |
Test Method |
Single cycle reversing d.c. ratiometric measurement -average result display |
|
Test Current |
||
Accuracy | ±10% | |
Stability | <10 ppm per second | |
Maximum Lead Resistance |
100 mΩ total for 10 A operation irrespective of battery condition. |
|
Voltmeter Input Impedance |
> 200 kΩ | |
Hum Rejection |
Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning will show if hum or noise exceeds this level. |
|
Data Transfer |
- | Real Time or from storage via RS232 |
Storage | - | 700 tests |
Memo Field |
- | Up to 200 characters per test via integral alphanumeric keypad |
Battery Capacity |
7 Ah NiMH rechargeable |
|
Battery Life |
Typical 1000 x 10A Tests Before Recharge |
|
Recharge | Via external 90 V - 260 V 50/60 Hz charger or from 12 to 15 V dc supply |
|
Standard Charging Rate |
2.5 hours to 90% capacity, 4 hrs for full charge |
|
Temperature | +5 ºC to +45 ºC (41 ºF to 113 ºF) at full specification -10 ºC to +50 ºC (14 ºF to 122 ºF) at reduced accuracy |
|
Storage Co-Efficient |
-30 ºC to +70 ºC (-22 ºF to 158 ºF) | |
Slow Charging |
<0.01% per ºC over range 5 ºC to 40 ºC (<0.006% per ºF from 4 1ºF to 104 ºF) |
|
Humidity (MAX) |
+10 ºC to +45 ºC (50 ºF to 113 ºF) | |
Altitude (MAX) |
90% RH @ 40 ºC (104 ºF) non-condensing | |
Safety |
2000 m (6562 ft) to full safety specifications | |
EMC | In accordance with IEC61010-1 600 V Category III - only when DH6 leads are used. In accordance with IEC61326-1 |
|
Dimensions | 220 x 100 x 237 mm (8.6 x 4 x 9.5 in) | |
Weight | 2.6 kg (5 3/4 lb.) including battery module | |
* The accuracy stated assumes forward and reverse measurements. Inductive mode or undirectional mode will introduce an undefined error if an external EMF is present. |