The most advanced clamp meter in Megger's DCM300 range, the DCM340 performs every test you'll need for installing, maintaining, monitoring and checking electrical systems, installations and equipment.
Both an AC and DC clamp meter, the DCM340 can measure AC/DC current to 600A and voltage to 600V. Resistance measurements up to 400Ω can also be calculated and continuity/frequency testing functions are also included.
The Megger DCM340 has 35mm diameter jaws, making it suitable for smaller to medium-sized conductors. It also comes with a selection of advanced features such as digital bargraph, peak, min/max and data hold functions and is compliant with IEC61010 CAT III 600V.
This digital clamp meter is perfectly suitable for use in heavy-duty industrial applications thanks to 1.2m drop protection.
Please find below the accessories available for the Megger DCM340 Digital Clamp Meter. For further information please contact our sales team.
Our SKU | Megger's Part Number | Product |
MEGITA1 | 1002-001B | Unfused Lead Set, Red/Black (Boxed) |
MEGRCDA4 | 1002-015B | Fused Lead Set, Red/Black (Boxed) |
Please note that the accessories listed above and the datasheets attached are subject to change. Both were correct at the time of publication. |
AC Current | Accuracy (50/60Hz) | Accuracy (61 - 400Hz) |
---|---|---|
0 - 60A | ±1.9% ± 7 digits |
±2.5% ± 7 digits |
60 - 400A | ± 1.9% ± 5 digits |
± 2.5% ± 5 digits |
400 - 600A | ± 2.5% ± 5 digits |
± 2.9% ± 5 digits |
DC Current | Accuracy | |
0 - 60A | ± 1.5% ± 10 digits |
|
60 - 400A | ± 1.9% ± 5 digits |
|
400 - 600A | ± 1.9% ± 10 digits |
|
Voltage | Accuracy (50-500Hz) | Accuracy (DC) |
0 - 400V | ± 1.0% ± 5 digits |
± 0.7% ± 2 digits |
400 - 600V | ± 1.0% ± 5 digits |
± 0.7% ± 2 digits |
Input Impedance | 1MΩ // <100pF | |
Resistance and Continuity | Accuracy | |
0 - 400Ω | ± 1% ± 3 digits |
|
Open Circuit Voltage | 3V | |
Continuity Check | Beeper sounds @ <30Ω | |
Frequency | Resolution/Range | Accuracy |
20- 400Hz | 1Hz | ± 0.1% ± 2 digits |
Sensitivity | 3A | |
Peak Hold | ±3% ± 15 digits |
|
Sample Time | 10ms | |
MIN/MAX Hold | Add 15 digits to accuracy for AC and DC | |
Positional Error | ±1% of reading |
|
Overload Protection | 600V and 600A rms | |
AC Conversion | Average sensing rms indication calibrated to the rms value of a sine wave input | |
Auto Power Off | 30 minutes after power on |