The Megger PAM410 phase angle meter is specifically designed for measurements of electrical power systems. It is capable of displaying the phase angle relationship between two power signals, which can be two currents, two voltages, or any combination. Currents up to 25 A and voltages up to 500 V can be applied directly to the instrument and the current input range can be extended by using external current transformers.
The PAM410 is suitable for checking polyphase metering installations, testing protective relays, making comparative tests in electrical substations, and verifying the phase angle deviation on power transformers.
PAM410 | |||
---|---|---|---|
Specifications are valid at nominal input voltage and an ambient temperature of +25°C, (77°F). Specifications are subject to change without notice. | |||
Environment | |||
Application Field | The instrument is intended for use in high-voltage substations and industrial environments | ||
Temperature | Operating | -10°C to +50°C (14°F to +122°F) | |
Storage & Transport | -40°C to +70°C (-40°F to +158°F) | ||
Humidity | 5% - 95% RH, non-condensing | ||
Altitude | < 2000 m above sea level | ||
CE-Marking | |||
LVD | 2014/35/EU | ||
EMC | 2014/30/EU | ||
RoHS | 2011/65/EU | ||
General | |||
Measurement Category | CAT III 500 V, CAT IV 300 V | ||
Enclosure Class | IP21 | ||
Power Supply | Rechargeable batteries | ||
Mains Adapter | 100 - 240 V AC, 50 / 60 Hz | ||
Adapter Output Voltage | 9 V DC | ||
Power Consumption | 10 W (max) | ||
Dimensions | Instrument | 260 x 140 x 55 mm (except handle), (10.2” x 5.5” x 2.2”) | |
Transport Case | 390 x 300 x 140 mm, (15.4” x 11.8” x 5.5”) | ||
Weight | 1.2 kg (2.6 lbs) Instrument 3.5 kg (7.7 lbs) with accessories and transport case |
||
Test Lead Set, with 4 mm Stackable Safety Plugs | Black 2 x 2 m (6.6 ft), 2.5 mm2, Red 2 x 2 m (6.6 ft), 2.5 mm2 | ||
Display | Alphanumerical LC display with back-lighter | ||
Phase Angle Measurement | |||
Range | 0 - 359.9° (2 - 500 V and 0.15 - 25 A) | ||
Type of Phase Angle Measurement | Current-current, voltage-voltage, and current-voltage | ||
Waveform | Sinusoidal | ||
Resolution | 0.1° | ||
Inaccuracy | ±0.5° at >10% of the voltage/current range ±1° at 2- 10% of the voltage/current range ±2° at 1- 2% of voltage/current range |
||
Internal Battery | Rechargeable Li-ion battery, replaceable by accredited service centre only |
SKU | BP-39090 |
---|---|